From Siemens Medical Systems;
The Magnetom Trio™, a 3T whole body MRI system with Tim (total imaging matrix technology), targets clinical applications such as abdominal, cardiac, spine, whole body and orthopedics. TIM enables flexible coil combinations
for high resolution imaging of large anatomical areas
without the need to change coils.
|
|
Device Information and Specification |
| CLINICAL APPLICATION |
Whole body |
| CONFIGURATION |
Short bore |
| SURFACE COILS |
CP head, CP integrated body coil, neck matrix, breast array, 8-channel knee array, CP wrist, shoulder array, CP extremity |
| SPECTROSCOPY |
Yes/Mutli-nuclear MRS |
| PULSE SEQUENCES |
SE, IR, 2D/3D TurboSE, Turbo IR, Dark-Fluid IR, True IR, 2D/3D MEDIC, 2D/3D GRE FLASH, 2D/3D GRE FISP, 2D/3D PSIF, 2D TurboFLASH, 3D MP-RAGE, 3D TurboFLASH, 2D/3D TOF angiography, MTC, TONE with 3D TOF MRA, GMR, LOTA |
| IMAGING MODES |
Single, multislice, volume study, multi angle, multi oblique |
| SINGLE/MULTI SLICE |
178 images/sec at 256 x 256 at 100% FOV |
| FOV |
40 cm |
| SLICE THICKNESS |
Min 2D/3D: 0.1/0.05 mm |
| DISPLAY MATRIX |
1024 x 1024 full screen display |
| MEASURING MATRIX |
64 x 64 to 1024 x 1024 |
| SPATIAL RESOLUTION |
10 micrometer |
| MAGNET TYPE |
Superconducting |
BORE DIAMETER or W x H |
60 cm |
| MAGNET WEIGHT |
12000 kg |
| H*W*D |
221 x 244 x 213 cm |
| POWER REQUIREMENTS |
380/400/420/440/480 V |
| COOLING SYSTEM TYPE |
Single cryogen, 2 stage refrig. |
| CRYOGEN USE |
0.12 L/hr helium |
| FIELD STRENGTH |
3 tesla (3T) |
| STRENGTH |
40 - 45 mT/m |
| SLEW RATE |
200 mT/m/ms |
| 5-GAUSS FRINGE FIELD |
3.4 m / 5.9 m |
| SHIMMING |
Passive, act.; 1st order std./2nd opt. |
|
| |  | |
Further Reading: |
Basics:
|
| | |
|  |
 |
MRI Resources |
|
| | | |  |  |  |
| |
|
The range of diagnostics and imaging systems of Siemens Medical Systems covers ultrasound, nuclear medicine, angiography, magnetic resonance, computer tomography and patient monitoring. Siemens is one of the three leading MRI manufacturers, which together account for approximately 80 percent of the MRI machines installed worldwide. Siemens currently offers the Allegra 3T MRI, which is for head scanning only, but the company will also be launching the Trio MRI, a 3T whole body scanner.
Siemens has formed partnerships with more than ten research institutions and private practitioners to define a comprehensive MRI examination and compare MR to currently established cardiovascular modalities, thereby defining optimal diagnosis and treatment.
MRI Related Product Lines:
| |
|
|
| |  | |
Further Reading: |
Basics:
|
|
News & More:
| | | | | | •• There are 3 news about 'Siemens Medical Systems'. | |
|  |
 |
Searchterm 'MAGNETOM Trio'
was also found in the following service of MR-TIP.com: |
|
| | | |
|
 |
|
 |
MRI Resources |
|
| | | |  |  | |
|  |  | 1 - 2 (of 2) Result Pages : [1] |
| |
|
| |
 | Look Ups |
| |