Magnetic Resonance - Technology Information Portal Welcome to MRI Technology••
Info
  Sheets


Out-
      side
 



 
 'MAGNETOM C' 
SEARCH FOR    
 
  2 3 5 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Result : Searchterm 'MAGNETOM C' found in 2 terms [] and 1 definition [], (+ 15 Boolean[] results
1 - 5 (of 18)     next
Result Pages : [1]  [2 3 4]
Searchterm 'MAGNETOM C' was also found in the following services: 
spacer
News  (15)  Resources  (5)  Forum  (2)  
 
MAGNETOM CInfoSheet: - Devices -
Intro, 
Types of Magnets, 
Overview, 
etc.MRI Resource Directory:
 - Devices -
 
From Siemens Medical Systems;
www.medical.siemens.com A new, powerful, compact player in MRI. For both, patients and health care professionals, the mid-field has realized a giant step to cost efficient quality care. Obese patients and people with claustrophobia appreciate the comfortable side loading. The smallest pole diameter - 137 cm (54 inches) allows for optimal patient comfort.

Device Information and Specification
CLINICAL APPLICATION Whole body
CONFIGURATION C-shaped open MRI
SURFACE COILS Multi channel imaging, CP Head//Neck Array Coil, Body/Spine Array Coil, large, Transmit Coil
SYNCHRONIZATION ECG/peripheral: Optional/yes, respiratory gating
PULSE SEQUENCES SE, FLASH, FISP, IR, FIR, STIR, TrueIR/FISP, FSE, MT, SS-FSE, MT-SE, MTC, MSE, EPI, PSIF,
IMAGING MODES Single, multislice, volume study, multi angle, multi oblique
TR Min. TR 2.81 ms
TE Min. TE 0.98 ms
DISPLAY MATRIX 512 x 512 full screen display
MEASURING MATRIX 64 x 64 to 512 x 512
FOV 0.5 - 40 cm
MAGNET TYPE Permanent
BORE DIAMETER
or W x H
41 cm vertical gap distance
MAGNET WEIGHT 16000 kg
H*W*D 233 x 206 x 160 cm
FIELD STRENGTH 0.35 T
STRENGTH 24 mT/m
5-GAUSS FRINGE FIELD 2.2 m / 2.2 m
SHIMMING Passive and active
spacer
 
• Share the entry 'MAGNETOM C™':  Facebook  Twitter  LinkedIn  
 
• Related Searches:
    • MRI Equipment
    • Hardware
    • Device
    • Open MRI
    • Permanent Magnet
 
Further Reading:
  Basics:
Section 2: 510(k) Summary, MAGNETOM C! System Classification Name: Magnetic Resonance Diagnostic(.pdf)
   by www.accessdata.fda.gov    
MRI Resources 
Directories - Spectroscopy - Corporations - Implant and Prosthesis pool - Knee MRI - Cardiovascular Imaging
 
MAGNETOM Concerto™InfoSheet: - Devices -
Intro, 
Types of Magnets, 
Overview, 
etc.MRI Resource Directory:
 - Devices -
 
From Siemens Medical Systems;
www.med.siemens.com/med/d/gg/mr/products/concerto.htm the MAGNETOM Concerto is easy to site and has low life cycle costs due to the permanent magnet. The powerful gradient system with 20 mT/m and a slew rate of 40 T/m/s permits high field applications on a low field open MRI system. The three-sided fully open magnet results in maximum acceptance of claustrophobic or anxious patients and patient access.
Device Information and Specification
CLINICAL APPLICATION Whole body
CONFIGURATION Open MRI
SURFACE COILS Body coil, head brain, spine, knee, neck, TMJ, extremity, shoulder, others
SPECTROSCOPY No
PULSE SEQUENCES GRE, IR, FIR, STIR, TrueIR/FISP, FSE, MT, SS-FSE, MT-SE, MTC, MSE, GMR, fat/water sat./exc.
IMAGING MODES Single, multislice, volume study, multi angle
SLICE THICKNESS Min 2D/3D: 0.1/0.05 mm
DISPLAY MATRIX 512 x 512 full screen display
MEASURING MATRIX 64 x 64 to 512 x 512
SPATIAL RESOLUTION 22 micrometer
MAGNET TYPE Permanent
MAGNET WEIGHT 11 000 kg
POWER REQUIREMENTS 380/400/420/440/480 V
FIELD STRENGTH 0.2 T
STRENGTH 20 mT/m
SHIMMING Passive, active
spacer

• View the DATABASE results for 'MAGNETOM Concerto™' (2).Open this link in a new window

MRI Resources 
Sequences - Cochlear Implant - Breast Implant - Patient Information - Diffusion Weighted Imaging - Safety Products
 
Siemens Medical Systems
 
www.siemensmedical.com The range of diagnostics and imaging systems of Siemens Medical Systems covers ultrasound, nuclear medicine, angiography, magnetic resonance, computer tomography and patient monitoring. Siemens is one of the three leading MRI manufacturers, which together account for approximately 80 percent of the MRI machines installed worldwide. Siemens currently offers the Allegra 3T MRI, which is for MRI, a 3T whole body scanner.
Siemens has formed partnerships with more than ten research institutions and private practitioners to define a comprehensive MRI examination and compare MR to currently established cardiovascular modalities, thereby defining optimal diagnosis and treatment.

MRI Scanners:
– 0.2T to 1.0T:
•
MAGNETOM Concerto™
•
MAGNETOM Jazz™
•
MAGNETOM C™
•
MAGNETOM Harmony™
•
MAGNETOM Rhapsody™
– 1.5T:
•
MAGNETOM Aera
•
MAGNETOM Avanto™
•
MAGNETOM Espree™
•
MAGNETOM ESSENZA
•
MAGNETOM Sonata™
•
MAGNETOM Symphony™
– 3.0T to 7.0T:
•
MAGNETOM Allegra™
•
MAGNETOM Prisma
•
MAGNETOM Skyra
•
MAGNETOM Spectra
•
MAGNETOM Verio
•
MAGNETOM Trio™
•
MAGNETOM 7T
– Hybrid Scanners:
•
Biograph mMR
– Mobile Solutions:
MAGNETOM Espree 1.5T, MAGNETOM Avanto 1.5T and MAGNETOM ESSENZA 1.5T are also offered by Siemens on certified trailers.



Contact Information
MAIL Siemens Medical Solutions Health Services Corporation
51 Valley Stream Parkway
Malvern, PA 19355
USA
PHONE +1 610 219 6300
FAX +1 610 219 8266
E-MAIL contact@med.siemens.de
ONLINE siemensmedical.com
CONTACT INFO PAGE worldwide.med.siemens.com/contact
spacer

• View the DATABASE results for 'Siemens Medical Systems' (14).Open this link in a new window


• View the NEWS results for 'Siemens Medical Systems' (3).Open this link in a new window.
 
Further Reading:
  Basics:
New 3-tesla MRI scanner Magnetom Prisma from Siemens is designed to explore new frontiers in MRI application
Sunday, 25 November 2012   by www.siemens.com    
Siemens Announces FDA Clearance of Magnetom Amira MRI Scanner
Thursday, 21 January 2016   by www.itnonline.com    
  News & More:
The Most Exciting Equation in MRI Siemens MAGNETOM Verio Combines High-Field Imaging and a 70-cm Open-Bore Design
Wednesday, 31 October 2007   by www.biospace.com    
Siemens Working on Automated Planning of Cardiac MRI Views
Friday, 8 March 2013   by www.medgadget.com    
Searchterm 'MAGNETOM C' was also found in the following services: 
spacer
News  (15)  Resources  (5)  Forum  (2)  
 
MAGNETOM Spectra
 
From Siemens Medical Systems;
www.healthcare.siemens.com/magnetic-resonance-imaging/3t-mri-scanner/magnetom-spectra Received FDA clearance in 2012.
The MAGNETOM Spectra is a cost-optimized high field MRI system with Tim 4G and Dot technologies. The system consumes less energy compared to other 3 Tesla scanners. The magnet-cooling helium is contained in a closed loop, which prevents the gas from escaping and reduces the need for refills. TimTX includes innovative techniques in the radio frequency excitation hardware as well as new application and processing features enabling uniform RF distribution in all body regions.


Device Information and Specification
CLINICAL APPLICATION Whole Body
CONFIGURATION Short bore
FIELD STRENGTH 3 Tesla
SURFACE COILS Head, spine, torso/ body coil, neurovascular, neck and multi-purpose flex coils. Peripheral vascular, breast, shoulder, knee, wrist, foot//ankle, endorectal optional.
CHANNELS 24
SPECTROSCOPY Chemical shift imaging, single voxel spectroscopy
IMAGING TECHNIQUES iPAT, mSENSE and GRAPPA (image, k-space), noncontrast angiography, radial motion compensation
FOV 0.5 - 45 cm
BORE DIAMETER
or W x H
At isocenter: L-R 60 cm
TABLE CAPACITY 200 kg
MAGNET WEIGHT 7200 kg
DIMENSION H*W*D (gantry included) 173 x 231 x 219 cm
5-GAUSS FRINGE FIELD 2.6 m / 4.6 m
MAGNET TYPE Superconducting
CRYOGEN USE Zero boil off rate, approx. 10 years
COOLING SYSTEM Water; single cryogen, 2 stage refrigeration
SLEW RATE up to 125 T/m/s
MAX. AMPLITUDE 33 mT/m
SHIMMING Passive, active; first order standard, second order optional
POWER REQUIREMENTS 380 / 400 / 420 / 440 / 460 / 480 V, 3-phase + ground; connection value with chiller 100 kvA /without chiller 60 kVA
spacer
MRI Resources 
Image Quality - Musculoskeletal and Joint MRI - Safety Products - Service and Support - Case Studies - Guidance
 
MAGNETOM Prisma
 
From Siemens Medical Systems;
www.healthcare.siemens.com/magnetic-resonance-imaging/3t-mri-scanner/magnetom-prisma Received FDA clearance in 2013.
The MAGNETOM Prisma is the 3T PowerPack for exploration that offers most demanding clinical and research challenges of today and the future. The latest parallel transmit technology, TimTX TrueShape, enables zooming into specific body regions for enhanced image quality. Furthermore, the Tim 4G integrated coil technology offers remarkable imaging flexibility and supports complex examinations across the whole body.
Onsite upgrades to the MAGNETOM Prisma for customers who have already installed the 3 Tesla MAGNETOM Trio are possible.


Device Information and Specification
CLINICAL APPLICATION Whole Body
CONFIGURATION Ultra-short bore
FIELD STRENGTH 3 Tesla
SURFACE COILS Head, spine, torso/ body coil, neurovascular, cardiac, neck, shoulder, knee, wrist, foot//ankle and multi-purpose flex coils. Peripheral vascular, breast, shoulder.
CHANNELS (min. / max. configuration) 64, 128
SPECTROSCOPY Yes
IMAGING TECHNIQUES iPAT, mSENSE and GRAPPA (image, k-space), noncontrast angiography, radial motion compensation, Dixon
FOV 0.5 - 50 cm
BORE DIAMETER
or W x H
At isocenter: L-R 60 cm
TABLE CAPACITY 250 kg
MAGNET WEIGHT (gantry included) 13000 kg
DIMENSION H*W*D (gantry included) 173 x 230 x 222 cm
5-GAUSS FRINGE FIELD 2.6 m / 4.6 m
MAGNET TYPE Superconducting
CRYOGEN USE Zero boil off rate, refill approx. 10 years
COOLING SYSTEM Water
SLEW RATE up to 200 T/m/s
MAX. AMPLITUDE 80 mT/m
SHIMMING Passive, active; first order, second order
POWER REQUIREMENTS 380 / 400 / 420 / 440 / 460 / 480 V, 3-phase + ground;
spacer
MRI Resources 
Anatomy - Education pool - MRI Technician and Technologist Schools - Chemistry - Shoulder MRI - Online Books
 
     1 - 5 (of 18)     next
Result Pages : [1]  [2 3 4]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?  



Your MRI scanner(s) in 5 years should be :
more automated 
much quicker 
quiet 
voice controlled 
iPhone compatible 
as it is right now 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • US-TIP • The-Medical-Market
Copyright © 2003 - 2016 SoftWays. All rights reserved. [ 20 September 2017]
Terms of Use | Privacy Policy | Advertising
 [last update: 2017-09-05 04:51:00]