Magnetic Resonance - Technology Information Portal Welcome to MRI Technology••
Info
  Sheets


Out-
      side
 



 
 'Device Information' 
SEARCH FOR    
 
  2 3 5 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Result : Searchterm 'Device Information' found in 0 term [] and 70 definitions []
previous     51 - 55 (of 70)     next
Result Pages : [1 2 3 4 5 6 7 8 9 10 11 12 13 14]
Searchterm 'Device Information' was also found in the following services: 
spacer
News  (2)  Resources  (4)  
 
RELAX 0.35T™InfoSheet: - Devices -
Intro, 
Types of Magnets, 
Overview, 
etc.MRI Resource Directory:
 - Devices -
 
www.isoltech.co.kr/english/product/035t.htm From ISOL Technology
'RELAX is open type MRI system created by making up for the weakness of existing conventional MR systems and applying the strength and the application of the middle to high field MR without uncompromising the image quality.
RELAX offers you a premium mix of form, performance and functionality that are patient and user friendly beyond comparison. - New breed of MRI pursuing - patients comfort'

Device Information and Specification
CLINICAL APPLICATION Whole body
CONFIGURATION Open
SURFACE COILS Head, C-spine, L-spine, TMJ, Knee, Shoulder, General purpose, Phased Array System: 4 digital receiver channels (Up to 12 channels)
SYNCHRONIZATION ECG/peripheral: Optional/yes, respiratory gating
PULSE SEQUENCES 2D/3D Spin echo, 2D/3D Gradient echo, 2D/3D Fast spin echo, Inversion recovery, 2D/3D Fast gradient echo sequences, FLAIR/STIR, 2D/3D TOF
IMAGING MODES 3D volume imaging (MIP, MPR) MR Angiography package
FOV 30 cm
MAGNET TYPE Permanent
BORE DIAMETER
or W x H
40 cm diameter (patient)
MAGNET WEIGHT 13500 kg
H*W*D 170 x 210 x 130 cm
COOLING SYSTEM TYPE Water-cooled coil and air-cooled amplifier
FIELD STRENGTH 0.35 T
STRENGTH 25 - 30 mT/m
5-GAUSS FRINGE FIELD lower than 2.4 m from the iso-center
SHIMMING Passive and active
spacer
MRI Resources 
Diffusion Weighted Imaging - General - Software - RIS - Databases - Supplies
 
S-SCANInfoSheet: - Devices -
Intro, 
Types of Magnets, 
Overview, 
etc.
 
www.esaote.com/products/MRI/sScan/products1.htm From Esaote S.p.A.; Esaote introduced the S-SCAN at RSNA in November 2007. The S-SCAN is a dedicated joint and spine MR scanner derived from the company's earlier G-SCAN system. Unlike the G-SCAN, neither the patient table nor the magnet can rotate from horizontal to vertical position. The patient table can only moved manually. Improved electronics, new coils for lumbar and cervical spine, new pulse sequences, a modified version of the magnet poles and gradient coils are used with a new software release in the S-SCAN.
Esaote North America is the exclusive U.S. distributor of this MRI device.
Device Information and Specification (Under Development)
CLINICAL APPLICATION Musculoskeletal, extremity
CONFIGURATION Open MRI
SURFACE COILS 4-channel phased array spine coil, extremity, shoulder, flex coil, knee dual phased array, ankle//foot dual phased array, hand//wrist dual phased array
PULSE SEQUENCES SE, GE, IR, STIR, TSE, 3D CE, GE-STIR, 3D GE, ME, TME, HSE
IMAGING MODES Single, multislice, volume study, fast scan, multi slab, cine
FOV 25 cm
DISPLAY MATRIX 512 x 512
MEASURING MATRIX 256 x 256 maximum
MAGNET TYPE Permanent
BORE DIAMETER
or W x H
33 cm H, open
POWER REQUIREMENTS 3 kW; 110/220 V single phase
FIELD STRENGTH 0.25 T
STRENGTH 25 mT/m
5-GAUSS FRINGE FIELD, radial/axial 180 cm
SHIMMING Passive
spacer

• View the DATABASE results for 'S-SCAN' (3).Open this link in a new window


• View the NEWS results for 'S-SCAN' (1).Open this link in a new window.
 
Further Reading:
  News & More:
Wichita medical facility gets first Hologic S-scan MRI in the United States
Friday, 19 October 2007   by wichita.bizjournals.com    
MRI Resources 
Non-English - Spectroscopy pool - Corporations - Cardiovascular Imaging - Musculoskeletal and Joint MRI - MRCP
 
Signa 3.0T™InfoSheet: - Devices -
Intro, 
Types of Magnets, 
Overview, 
etc.MRI Resource Directory:
 - Devices -
 
(Signa VH/i 3.0T)
www.gehealthcare.com/usen/mr/s_excite3/index.html With GE Healthcare leading-edge technology in ultra-high-field imaging. The 3 T VH/i provides a platform for advanced applications in radiology, cardiology, psychology and psychiatry. Real-time image processing lets you acquire multislice whole brain images and map brain functions for research or surgical planning. And the 3 T Signa VH/i is flexible enough to provide clinicians with high performance they require. It can provide not only outstanding features in brain scanning and neuro-system research, but also a wide range of use in scanning breasts, extremities, the spine and the cardiovascular systems.

Device Information and Specification
CLINICAL APPLICATION Whole body
CONFIGURATION Cylindrical - high homogeneity
SURFACE COILS T/R quadrature head, T/R quadrature body, T/R phased array extremity (opt)
SPECTROSCOPY Single voxel and 2D CSI proton
SYNCHRONIZATION ECG/peripheral, respiratory gating
PULSE SEQUENCES SE, IR, 2D/3D GRE, FGRE, RF-spoiled GRE, FSE, Angiography: 2D/3D TOF, 2D/3D phase contrast vascular
IMAGING MODES Single, multislice, volume study, fast scan, multi slab, cine, localizer
SINGLE SLICE 100 Images/sec with Reflex100
MULTISLICE 100 Images/sec with Reflex100
FOV 1 cm to 40 cm continuous
SLICE THICKNESS 2D 0.5-100mm in 0.1mm incremental
DISPLAY MATRIX 1280 x 1024
MEASURING MATRIX 128x512 steps 32 phase encode
PIXEL INTENSITY 256 gray levels
SPATIAL RESOLUTION 0.02mm
MAGNET TYPE Superconducting
BORE DIAMETER
or W x H
55cm
MAGNET WEIGHT 15102 kg incl. cryogen's
H*W*D 260cm x 238cm x 265cm
POWER REQUIREMENTS 480 or 380/415, 3 phase ||
COOLING SYSTEM TYPE Closed-loop water-cooled grad.
CRYOGEN USE Less than 0.14 L/hr liquid He
FIELD STRENGTH 3 T
STRENGTH 40mT/m
5-GAUSS FRINGE FIELD, radial/axial 5.4 m x 3.2 m
SHIMMING Superconductive + hi order active
spacer

• View the DATABASE results for 'Signa 3.0T™' (2).Open this link in a new window

Searchterm 'Device Information' was also found in the following services: 
spacer
News  (2)  Resources  (4)  
 
Signa Contour/i 0.5T™InfoSheet: - Devices -
Intro, 
Types of Magnets, 
Overview, 
etc.MRI Resource Directory:
 - Devices -
 
www.gemedical.co.kr/rad/mri/products/contour/contouri.html From GE Healthcare;
GE's Signa Contour/i system uses the innovations like K4 technology and real-time interactive imaging. This compact magnet with wide-flare gantry obtains high patient comfort with low costs.

Device Information and Specification
CLINICAL APPLICATION Whole body
CONFIGURATION Compact
SURFACE COILS Head and body coil standard; all other coils optional; open architecture makes system compatible with a wide selection of coils
SYNCHRONIZATION ECG/peripheral, respiratory gating
PULSE SEQUENCES Standard: SE, IR, 2D/3D GRE and SPGR, Angiography;; 2D/3D TOF, 2D/3D Phase Contrast;; 2D/3D FSE, 2D/3D FGRE and FSPGR, SSFP, FLAIR, optional: EPI, 2D/3D Fiesta, FGRET, Spiral
IMAGING MODES Localizer, single slice, multislice, volume, fast, POMP, multi slab
FOV 1 cm to 48 cm continuous
SLICE THICKNESS 2D 0.8 mm to 20 mm; 3D 0.1 mm to 5 mm
DISPLAY MATRIX 1280 x 1024
MEASURING MATRIX 128x512 steps 32 phase encode
PIXEL INTENSITY 256 gray levels
SPATIAL RESOLUTION 0.08 mm
MAGNET TYPE Superconducting
BORE DIAMETER 60 cm
POWER REQUIREMENTS 480 or 380/415 V
COOLING SYSTEM TYPE Closed-loop water-cooled gradient
FIELD STRENGTH 0.5 T
STRENGTH SmartSpeed 23 mT/m, HiSpeed Plus 33 mT/m
SHIMMING Active
spacer
MRI Resources 
Artifacts - Blood Flow Imaging - Bioinformatics - MRI Centers - Crystallography - Safety Products
 
Signa HDe 1.5T™InfoSheet: - Devices -
Intro, 
Types of Magnets, 
Overview, 
etc.
 
From GE Healthcare;
www.vitalcom.com/euen/mri/products/signa-hde-15t/index.html GE Healthcare has added the Signa HDe 1.5T™, a compact MRI device at an affordable price to its family of MRI products. It has a single electronic cabinet that can be positioned inside the scanner room rather than in a separate equipment room. The Signa HDe 1.5T can be installed in the same physical location as 0.5T MRI systems with minimal construction costs. According to GE, the installation has been simplified to last only 7 days and has a 30 percent smaller footprint than a typical 1.5T system.
The 1.5T Signa™ HDe MRI system is substantially equivalent to the currently marketed GE 1.5T machines. The data acquisition system supports 1, 4, 8 independent receive channels and multiple independent coil elements per channel during a single acquisition series. The gradient specifications of HDe are lower than other GE Signa 1.5T MRI systems, but it can support clinical applications in cardiac and spectroscopy imaging.

Device Information and Specification
CLINICAL APPLICATION Whole body
CONFIGURATION Compact short bore
SURFACE COILS Head and body coil standard; all other coils optional e.g., abdomen, spine, breast, knee, shoulder, cardiac imaging coils
SPECTROSCOPY Possible
SYNCHRONIZATION ECG/peripheral, respiratory gating, (SmartPrep, SmartStep)
PULSE SEQUENCES Standard: SE, IR, 2D/3D GRE and SPGR, Angiography: 2D/3D TOF, 2D/3D Phase Contrast; 2D/3D FSE, 2D/3D FGRE and FSPGR, SSFP, FLAIR, EPI
IMAGING MODES 2D single slice, multi slice, and 3D volume images, multi slab, cine
FOV 1 cm to 48 cm continuous
SLICE THICKNESS 2D 0.7 mm to 20 mm; 3D 0.1 mm to 5 mm
DISPLAY MATRIX 1028 x 1024
MEASURING MATRIX 128x512 steps 32 phase encode
PIXEL INTENSITY 256 gray levels
MAGNET TYPE Superconducting
POWER REQUIREMENTS 480 or 380/415
COOLING SYSTEM TYPE Closed-loop water-cooled gradient
CRYOGEN USE, L/hr less than 0.03 L/hr liquid helium
FIELD STRENGTH 1.5 T
spacer

• View the NEWS results for 'Signa HDe 1.5T™' (1).Open this link in a new window.
 
Further Reading:
  Basics:
Signa HDe 1.5T
   by www.gehealthcare.com/    
MRI Resources 
Research Labs - Libraries - NMR - Safety pool - MRI Reimbursement - Mobile MRI Rental
 
previous      51 - 55 (of 70)     next
Result Pages : [1 2 3 4 5 6 7 8 9 10 11 12 13 14]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?  



The impact of TTIP/TPP on the MRI scanner market will bring :
more variety 
better scanners 
more risk 
less regulation 
cheaper scanners 
Lost in Translation 
no change at all 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • US-TIP • 
Copyright © 2003 - 2018 SoftWays. All rights reserved. [ 21 May 2019]
Terms of Use | Privacy Policy | Advertising
 [last update: 2018-03-08 05:11:00]