Magnetic Resonance - Technology Information Portal Welcome to MRI Technology
Info
  Sheets

Out-
      side
 



 
 'Magnetization' 
SEARCH FOR    
 
  2 3 5 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Result : Searchterm 'Magnetization' found in 11 terms [] and 116 definitions []
previous     91 - 95 (of 127)     next
Result Pages : [1 2 3]  [4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 ... ]
Searchterm 'Magnetization' was also found in the following services: 
spacer
News  (1)  Forum  (3)  
 
Magnetic Gradient
 
One of three linear magnetization waveforms superimposed on the main magnetic field at specific times within a pulse sequence to select the imaging region or provide necessary spatial localization information. A magnetic gradient is defined as the amount and direction of the linear rate of change of the magnetic field in space.
spacer

• View the NEWS results for 'Magnetic Gradient' (1).Open this link in a new window.
 
Further Reading:
  News & More:
Magnetic fields drive drug-loaded nanoparticles to reduce blood vessel blockages in an animal study
Monday, 19 April 2010   by www.eurekalert.org    
Active Noise Control of Magnetic Resonance Imaging Scanner Using Inverse Modeling Technique
Monday, 19 April 2010   by www.acoustics.org    
Searchterm 'Magnetization' was also found in the following service: 
spacer
Radiology  (3) Open this link in a new window
Magnetic Induction
 
(B) Also called magnetic flux density with the SI unit tesla (T) usually denoted by the symbol B. The magnetic induction is the net magnetic effect from an externally applied magnetic field and the resulting magnetization.
The symbol H was used for the magnetic field (measured in amperes per meter (A/m)). However, this distinction is often ignored, and both quantities are often referred to as the magnetic field.
B is proportional to H (B = μH).
(μ is the magnetic permeability (in henries per meter) of the medium)
spacer

• View the DATABASE results for 'Magnetic Induction' (5).Open this link in a new window

 
Further Reading:
  Basics:
Magnet basics
   by my.execpc.com    
  News & More:
Linear Collider Final FocusMagnet Construction
   by www.bnl.gov    
MRI Resources 
Quality Advice - Case Studies - Breast Implant - Cochlear Implant - Spectroscopy - Hospitals
 
Magnetic Resonance SpectroscopyMRI Resource Directory:
 - Spectroscopy pool -
 
(MRS / MRSI - Magnetic Resonance Spectroscopic Imaging) A method using the NMR phenomenon to identify the chemical state of various elements without destroying the sample. MRS therefore provides information about the chemical composition of the tissues and the changes in chemical composition, which may occur with disease processes.
Although MRS is primarily employed as a research tool and has yet to achieve widespread acceptance in routine clinical practice, there is a growing realization that a noninvasive technique, which monitors disease biochemistry can provide important new information for the clinician.
The underlying principle of MRS is that atomic nuclei are surrounded by a cloud of electrons, which very slightly shield the nucleus from any external magnetic field. As the structure of the electron cloud is specific to an individual molecule or compound, then the magnitude of this screening effect is also a characteristic of the chemical environment of individual nuclei.
In view of the fact that the resonant frequency is proportional to the magnetic field that it experiences, it follows that the resonant frequency will be determined not only by the external applied field, but also by the small field shift generated by the electron cloud. This shift in frequency is called the chemical shift (see also Chemical Shift). It should be noted that chemical shift is a very small effect, usually expressed in ppm of the main frequency. In order to resolve the different chemical species, it is therefore necessary to achieve very high levels of homogeneity of the main magnetic field B0. Spectra from humans usually require shimming the magnet to approximately one part in 100. High resolution spectra of liquid samples demand a homogeneity of about one part in 1000.
In addition to the effects of factors such as relaxation times that can affect the NMR signal, as seen in magnetic resonance imaging, effects such as J-modulation or the transfer of magnetization after selective excitation of particular spectral lines can affect the relative strengths of spectral lines.
In the context of human MRS, two nuclei are of particular interest - H-1 and P-31. (PMRS - Proton Magnetic Resonance Spectroscopy) PMRS is mainly employed in studies of the brain where prominent peaks arise from NAA, choline containing compounds, creatine and creatine phosphate, myo-inositol and, if present, lactate; phosphorus 31 MR spectroscopy detects compounds involved in energy metabolism (creatine phosphate, adenosine triphosphate and inorganic phosphate) and certain compounds related to membrane synthesis and degradation. The frequencies of certain lines may also be affected by factors such as the local pH. It is also possible to determine intracellular pH because the inorganic phosphate peak position is pH sensitive.
If the field is uniform over the volume of the sample, "similar" nuclei will contribute a particular frequency component to the detected response signal irrespective of their individual positions in the sample. Since nuclei of different elements resonate at different frequencies, each element in the sample contributes a different frequency component. A chemical analysis can then be conducted by analyzing the MR response signal into its frequency components.

See also Spectroscopy.
spacer

• View the DATABASE results for 'Magnetic Resonance Spectroscopy' (8).Open this link in a new window


• View the NEWS results for 'Magnetic Resonance Spectroscopy' (3).Open this link in a new window.
 
Further Reading:
  News & More:
Accuracy of Proton Magnetic Resonance Spectroscopy in Distinguishing Neoplastic From Non-neoplastic Brain Lesions
Saturday, 2 December 2023   by www.cureus.com    
Searchterm 'Magnetization' was also found in the following services: 
spacer
News  (1)  Forum  (3)  
 
Magnetic SusceptibilityForum -
related threads
 
(c) Magnetic susceptibility is the degree of magnetization of a material in response to a magnetic field. Paramagnetic materials strengthen the magnetic field, diamagnetic materials weaken it. The magnetic susceptibility of ferromagnetic substances is not linear; this is called differential susceptibility.
Differences in magnetic susceptibilities are a frequent cause of MRI artifacts.

See also Susceptibility Artifact, Magnetism, Diamagnetism, Paramagnetism, Ferromagnetism.
spacer

• View the DATABASE results for 'Magnetic Susceptibility' (15).Open this link in a new window

 
Further Reading:
  Basics:
Metal-Induced Artifacts in MRI
   by www.ajronline.org    
Magnetic susceptibility
   by en.wikipedia.org    
Searchterm 'Magnetization' was also found in the following service: 
spacer
Radiology  (3) Open this link in a new window
Modulus Image
 
Modulus images acquired with an Inversion Recovery Sequence do not take negative magnetization spin values into account. The "real" image, displayed with a bright background is recommended for correct tissue contrast.
spacer
MRI Resources 
Distributors - Colonography - Claustrophobia - Resources - Case Studies - NMR
 
previous      91 - 95 (of 127)     next
Result Pages : [1 2 3]  [4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 ... ]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



Next big thing in MRI will be :
AI 
remote operator 
personalized protocols 
helium-free 
molecular MRI 
portable MRI 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 9 May 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]