Magnetic Resonance - Technology Information Portal Welcome to MRI Technology
Info
  Sheets

Out-
      side
 



 
 'Magnetization' 
SEARCH FOR    
 
  2 3 5 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Result : Searchterm 'Magnetization' found in 11 terms [] and 116 definitions []
1 - 5 (of 127)     next
Result Pages : [1 2 3]  [4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 ... ]
Searchterm 'Magnetization' was also found in the following services: 
spacer
News  (1)  Forum  (3)  
 
Magnetization
 
The magnetic polarization of a material produced by a magnetic field (magnetic moment per unit volume).

See also Macroscopic Magnetization Vector.
spacer
 
• Share the entry 'Magnetization':  Facebook  Twitter  LinkedIn  
 
• Related Searches:
    • Magnet
    • Transverse Magnetization
    • Magnetic Forces
    • Longitudinal Magnetization
    • Excitation
Searchterm 'Magnetization' was also found in the following service: 
spacer
Radiology  (3) Open this link in a new window
Magnetization Value
 
(Mo) Equilibrium value of the magnetization;; directed along the direction of the static magnetic field. Proportional to spin density (N).
spacer

• View the DATABASE results for 'Magnetization Value' (3).Open this link in a new window

MRI Resources 
Most Wanted - Safety Training - Stent - Quality Advice - DICOM - Implant and Prosthesis pool
 
Magnetization Vector
 
The integration of all the individual nuclear magnetic moments, which have a positive magnetization value at equilibrium versus those in a random state.
spacer

• View the DATABASE results for 'Magnetization Vector' (18).Open this link in a new window

Searchterm 'Magnetization' was also found in the following services: 
spacer
News  (1)  Forum  (3)  
 
Magnetization Transfer
 
(MT) Magnetization Transfer was accidentally discovered by Wolff and Balaban in 1989. Conventional MRI is based on the differences in T1, T2 and the proton density (water content and the mobility of water molecules) in tissue; it relies primarily on free (bulk) water protons. The T2 relaxation times are greater than 10 ms and detectable. The T2 relaxation times of protons associated with macromolecules are less then 1 ms and not detectable in MRI.
Magnetization Transfer Imaging (MTI) is based on the magnetization interaction (through dipolar and/or chemical exchange) between bulk water protons and macromolecular protons. By applying an off resonance radio frequency pulse to the macromolecular protons, the saturation of these protons is then transferred to the bulk water protons. The result is a decrease in signal (the net magnetization of visible protons is reduced), depending on the magnitude of MT between tissue macromolecules and bulk water. With MTI, the presence or absence of macromolecules (e.g. in membranes, brain tissue) can be seen.
The magnetization transfer ratio (MTR) is the difference in signal intensity with or without MT.

See also Magnetization Transfer Contrast.
spacer

• View the DATABASE results for 'Magnetization Transfer' (7).Open this link in a new window

 
Further Reading:
  Basics:
MICRO-STRUCTURAL QUANTITIES - DIFFUSION, MAGNETISATION DECAY, MAGNETISATION TRANSFER AND PERMEABILITY(.pdf)
   by www.dundee.ac.uk    
The Basics of MRI
   by www.cis.rit.edu    
  News & More:
Gold-manganese nanoparticles for targeted diagnostic and imaging
Thursday, 12 November 2015   by www.nanowerk.com    
Magnetization Transfer Magnetic Resonance Imaging of Hepatic Tumors(.pdf)
   by www.nci.edu.eg    
Searchterm 'Magnetization' was also found in the following service: 
spacer
Radiology  (3) Open this link in a new window
Net Magnetization Vector
 
Hydrogen nuclei magnetic moments are randomly oriented in the absence of an external magnetic field and are considered to have a net magnetization of zero. Once hydrogen protons are placed in the presence of an external magnetic field, they align themselves in one of two directions, parallel or anti parallel to the net magnetic field, which is commonly referred to as the vector B0. The parallel and anti parallel protons cancel each other out, only the small number of low energy protons left aligned with the magnetic field create the overall net magnetization, this difference is all that counts. The magnetic moments of these protons are added together and are referred to as net magnetization vector (NMV) or the symbol 'M'.

See also Magnetization Transfer Contrast.
spacer

• View the DATABASE results for 'Net Magnetization Vector' (5).Open this link in a new window

 
Further Reading:
  Basics:
Mapping of low flip angles in magnetic resonance(.pdf)
Saturday, 1 January 2011   by www.hal.inserm.fr    
MRI Resources 
Health - Mobile MRI - NMR - Shoulder MRI - Case Studies - Veterinary MRI
 
     1 - 5 (of 127)     next
Result Pages : [1 2 3]  [4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 ... ]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



How AI will impact MRI :
only diagnostics 
saving time 
reducing cost 
makes planning obsolete 
reduce human knowledge 
not at all 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 19 March 2024]
Terms of Use | Privacy Policy | Advertising