Magnetic Resonance - Technology Information Portal Welcome to MRI Technology••
Info
  Sheets


Out-
      side
 



 
 'Device Information' 
SEARCH FOR    
 
  2 3 5 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Result : Searchterm 'Device Information' found in 0 term [] and 70 definitions []
previous     36 - 40 (of 70)     next
Result Pages : [1 2 3 4 5 6 7 8 9 10 11 12 13 14]
Searchterm 'Device Information' was also found in the following services: 
spacer
News  (2)  Resources  (4)  
 
MAGNETOM Sonata™InfoSheet: - Devices -
Intro, 
Types of Magnets, 
Overview, 
etc.MRI Resource Directory:
 - Devices -
 
From Siemens Medical Systems;
www.med.siemens.com/med/d/gg/mr/products/sonata.html while older navigator techniques take up to 40 minutes to create, the high performance of the MAGNETOM Sonata system enables 'complete examinations in less than 15 minutes'. It creates a new standard of diagnostic confidence and moves Cardiac MR from the research setting into routine clinical practice.

Device Information and Specification
CLINICAL APPLICATION Whole body
CONFIGURATION Compact
SURFACE COILS Body, head, spine, knee, neck, TMJ, extremity, head, breast, shoulder, others
SPECTROSCOPY Yes/SVS or CSI opt.
SYNCHRONIZATION ECG/peripheral, respiratory gating
PULSE SEQUENCES GRE, IR, FIR, STIR, TrueIR/FISP, FSE, FLAIR, MT, SS-FSE, MT-SE, MTC, MSE, EPI, 3D DESS//CISS/PSIF, GMR
IMAGING MODES Single, multislice, volume study, multi angle, multi oblique
TR 1.5 msec at 256matrix
TE 0.58 msec at 256matrix
SINGLE/MULTI SLICE 178 images/sec at 256 x 256 at 100% FOV
FOV 0.5 cm - 40 cm
SLICE THICKNESS Min 2D/3D: 0.1/0.05 mm
DISPLAY MATRIX 1024 x 1024 full screen display
MEASURING MATRIX 64 x 64 to 1024 x 1024
PIXEL INTENSITY
SPATIAL RESOLUTION 10 micrometer in plane
MAGNET TYPE Superconducting, single cryogen
BORE DIAMETER
or W x H
60 cm
MAGNET WEIGHT 4050kg, 5500kg in operation
H*W*D 236 x 215 x 160 cm
POWER REQUIREMENTS 380/400/420/440/480 V
COOLING SYSTEM TYPE Single cryogen, 2 stage refrig.
CRYOGEN USE Liquid He
FIELD STRENGTH 1.5 T
STRENGTH 40/70 mT/m
5-GAUSS FRINGE FIELD 2.5 m / 4.0 m
SHIMMING Passive, act.; 1st order std./2nd opt.
spacer
 
• Related Searches:
    • MRI Equipment
    • Device
    • Hardware
    • Low Field MRI
    • High Field MRI
MRI Resources 
Image Quality - Resources - Spectroscopy - Liver Imaging - Implant and Prosthesis pool - Manufacturers
 
MAGNETOM Spectra
 
From Siemens Medical Systems;
www.healthcare.siemens.com/magnetic-resonance-imaging/3t-mri-scanner/magnetom-spectra Received FDA clearance in 2012.
The MAGNETOM Spectra is a cost-optimized high field MRI system with Tim 4G and Dot technologies. The system consumes less energy compared to other 3 Tesla scanners. The magnet-cooling helium is contained in a closed loop, which prevents the gas from escaping and reduces the need for refills. TimTX includes innovative techniques in the radio frequency excitation hardware as well as new application and processing features enabling uniform RF distribution in all body regions.


Device Information and Specification
CLINICAL APPLICATION Whole Body
CONFIGURATION Short bore
FIELD STRENGTH 3 Tesla
SURFACE COILS Head, spine, torso/ body coil, neurovascular, neck and multi-purpose flex coils. Peripheral vascular, breast, shoulder, knee, wrist, foot//ankle, endorectal optional.
CHANNELS 24
SPECTROSCOPY Chemical shift imaging, single voxel spectroscopy
IMAGING TECHNIQUES iPAT, mSENSE and GRAPPA (image, k-space), noncontrast angiography, radial motion compensation
FOV 0.5 - 45 cm
BORE DIAMETER
or W x H
At isocenter: L-R 60 cm
TABLE CAPACITY 200 kg
MAGNET WEIGHT 7200 kg
DIMENSION H*W*D (gantry included) 173 x 231 x 219 cm
5-GAUSS FRINGE FIELD 2.6 m / 4.6 m
MAGNET TYPE Superconducting
CRYOGEN USE Zero boil off rate, approx. 10 years
COOLING SYSTEM Water; single cryogen, 2 stage refrigeration
SLEW RATE up to 125 T/m/s
MAX. AMPLITUDE 33 mT/m
SHIMMING Passive, active; first order standard, second order optional
POWER REQUIREMENTS 380 / 400 / 420 / 440 / 460 / 480 V, 3-phase + ground; connection value with chiller 100 kvA /without chiller 60 kVA
spacer
MRI Resources 
Musculoskeletal and Joint MRI - Safety Training - Developers - Distributors - Health - Image Quality
 
MAGNETOM Symphony™InfoSheet: - Devices -
Intro, 
Types of Magnets, 
Overview, 
etc.MRI Resource Directory:
 - Devices -
 
From Siemens Medical Systems;
www.med.siemens.com/med/d/gg/mr/products/symphony1.html with the introduction of this system, it is possible to perform contrast MR angiography for abdominal, thoracic and neck vessels from the origins to the circle of Willis. The system also has many newer features including functional imaging, spectroscopy, advanced body, ortho- and neuroimaging.

Device Information and Specification
CLINICAL APPLICATION Whole body
CONFIGURATION Compact
SURFACE COILS Body, head, spine, knee, neck, TMJ, extremity, breast, shoulder, others
SPECTROSCOPY Yes/SVS or CSI opt.
SYNCHRONIZATION ECG/peripheral, respiratory gating
PULSE SEQUENCES GRE, IR, FIR, STIR, TrueIR/FISP, FSE, FLAIR, MT, SS-FSE, MT-SE, MTC, MSE, EPI, GMR, fat/water sat./exc.
IMAGING MODES Single, multislice, volume study, multi angle, multi oblique
TR 2.4 msec std.; 2.0 opt.; 1.8 w/30 mT/m at 256matrix
TE 1.1 msec std.; 0.9 opt.; 0.78 w/30 mT/m at 256matrix
SINGLE/MULTI SLICE 178 images/sec at 256 x 256 at 100% FOV
FOV 0.5 cm - 50 cm
SLICE THICKNESS Min 2D/3D: 0.1/0.05 mm
DISPLAY MATRIX 1024 x 1024 full screen display
MEASURING MATRIX 64 x 64 to 1024 x 1024
PIXEL INTENSITY
SPATIAL RESOLUTION 21 micrometer in plane, 11 micrometer optional
MAGNET TYPE Superconducting, single cryogen
BORE DIAMETER
or W x H
60 cm
MAGNET WEIGHT 4050kg, 5500kg in operation
H*W*D 236 x 215 x 160 cm w/covers
POWER REQUIREMENTS 380/400/420/440/480 V
COOLING SYSTEM TYPE Single cryogen, 2 stage refrig.
CRYOGEN USE Liquid He
FIELD STRENGTH 1.5 T
STRENGTH 20/35 mT/m standard, 30/52 opt.
5-GAUSS FRINGE FIELD 2.5 m / 4.0 m
SHIMMING Passive, act.; 1st order std./2nd opt.
spacer

• View the DATABASE results for 'MAGNETOM Symphony™' (2).Open this link in a new window

 
Further Reading:
  Basics:
Symphony Brochure(.pdf)
Searchterm 'Device Information' was also found in the following services: 
spacer
News  (2)  Resources  (4)  
 
MAGNETOM Trio™ (TIM System)InfoSheet: - Devices -
Intro, 
Types of Magnets, 
Overview, 
etc.
 
From Siemens Medical Systems;
www.medical.siemens.com/webapp/wcs/stores/servlet/ProductDisplay?storeId=10001&langId=-11&catalogId=-11&catTree=100001%2C12786%2C12754&level=0&productId=145739 The Magnetom Trio™, a 3T whole body MRI system with Tim (total imaging matrix technology), targets clinical applications such as abdominal, cardiac, spine, whole body and orthopedics. TIM enables flexible coil combinations for high resolution imaging of large anatomical areas without the need to change coils.
Device Information and Specification
CLINICAL APPLICATION Whole body
CONFIGURATION Short bore
SURFACE COILS CP head, CP integrated body coil, neck matrix, breast array, 8-channel knee array, CP wrist, shoulder array, CP extremity
SPECTROSCOPY Yes/Mutli-nuclear MRS
PULSE SEQUENCES SE, IR, 2D/3D TurboSE, Turbo IR, Dark-Fluid IR, True IR, 2D/3D MEDIC, 2D/3D GRE FLASH, 2D/3D GRE FISP, 2D/3D PSIF, 2D TurboFLASH, 3D MP-RAGE, 3D TurboFLASH, 2D/3D TOF angiography, MTC, TONE with 3D TOF MRA, GMR, LOTA
IMAGING MODES Single, multislice, volume study, multi angle, multi oblique
SINGLE/MULTI SLICE 178 images/sec at 256 x 256 at 100% FOV
FOV 40 cm
SLICE THICKNESS Min 2D/3D: 0.1/0.05 mm
DISPLAY MATRIX 1024 x 1024 full screen display
MEASURING MATRIX 64 x 64 to 1024 x 1024
SPATIAL RESOLUTION 10 micrometer
MAGNET TYPE Superconducting
BORE DIAMETER
or W x H
60 cm
MAGNET WEIGHT 12000 kg
H*W*D 221 x 244 x 213 cm
POWER REQUIREMENTS 380/400/420/440/480 V
COOLING SYSTEM TYPE Single cryogen, 2 stage refrig.
CRYOGEN USE 0.12 L/hr helium
FIELD STRENGTH 3 tesla (3T)
STRENGTH 40 - 45 mT/m
SLEW RATE 200 mT/m/ms
5-GAUSS FRINGE FIELD 3.4 m / 5.9 m
SHIMMING Passive, act.; 1st order std./2nd opt.
spacer
MRI Resources 
MR Guided Interventions - MRI Technician and Technologist Jobs - Spine MRI - Collections - Spectroscopy pool - Services and Supplies
 
MAGNETOM Verio
 
From Siemens Medical Systems;
www.healthcare.siemens.com/magnetic-resonance-imaging/3t-mri-scanner/magnetom-verio Received FDA clearance in 2007.
The MAGNETOM Verio provides up to 102 integrated matrix coil elements and up to 32 independent radiofrequency channels that allow flexible coil combinations to make patient and coil repositioning virtually unnecessary. The Tim (total imaging matrix) technology also increases patient throughput due to a shorter scan time.
The open bore design offers great comfort for patients of all shapes and sizes.


Device Information and Specification
CLINICAL APPLICATION Whole Body
CONFIGURATION Ultra-short open bore
FIELD STRENGTH 3 Tesla
SURFACE COILS Head, spine, torso/ body coil, neurovascular, cardiac, neck and multi-purpose flex coils. Peripheral vascular, breast, shoulder, knee, wrist, foot//ankle, TMJ optional.
CHANNELS (min. / max. configuration) 8, 18, 32
SPECTROSCOPY Chemical shift imaging, single voxel spectroscopy
IMAGING TECHNIQUES iPAT, mSENSE and GRAPPA (image, k-space), noncontrast angiography, radial motion compensation, Dixon
MINIMUM TR 3-D GRE: 1.5 (256 matrix)
MINIMUM TE 3-D GRE: 0.63 (256 matrix)
FOV 0.5 - 50 cm
BORE DIAMETER
or W x H
At isocenter: L-R 70 cm, A-P 55 cm
TABLE CAPACITY 250 kg
MAGNET WEIGHT (gantry included) 8200 kg
DIMENSION H*W*D (gantry included) 173 x 230 x 222 cm
5-GAUSS FRINGE FIELD 2.6 m / 4.6 m
MAGNET TYPE Superconducting
CRYOGEN USE Zero boil off rate, refill approx. 10 years
COOLING SYSTEM Water
SLEW RATE up to 200 T/m/s
MAX. AMPLITUDE 45 mT/m
SHIMMING Passive, active; first order, second order standard
POWER REQUIREMENTS 380 / 400 / 420 / 440 / 460 / 480 V, 3-phase + ground; 110 kVA
spacer
MRI Resources 
MR Guided Interventions - Stimulator pool - Spectroscopy - MRI Reimbursement - Lung Imaging - MRA
 
previous      36 - 40 (of 70)     next
Result Pages : [1 2 3 4 5 6 7 8 9 10 11 12 13 14]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?  



The impact of TTIP/TPP on the MRI scanner market will bring :
more variety 
better scanners 
more risk 
less regulation 
cheaper scanners 
Lost in Translation 
no change at all 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • US-TIP • The-Medical-Market
Copyright © 2003 - 2016 SoftWays. All rights reserved. [ 22 May 2017]
Terms of Use | Privacy Policy | Advertising
 [last update: 2017-05-22 05:06:00]