Hybrid Spectroscopy
 
The combination of single volume spectroscopy and chemical shift imaging. The chemical shift measurement is performed over a selectively-excited volume of interest. Areas with strong distorting signal are not stimulated and therefore do not append signal to the spectra.

See also Hybrid Imaging.
spacer
 
Further Reading:
  News & More:
Near-IR Spectroscopy Performs Challenging Breast Imaging
Tuesday, 18 February 2014   by www.novuslight.com    
Searchterm 'Spectra' was also found in the following service: 
spacer
Ultrasound  (29) Open this link in a new window
In Phase Image
 
The term in phase refers to an image in which the signals from two spectral components (such as fat and water) add constructively in a voxel. T1 weighted in phase images are acquired by a gradient echo-based technique with a short TR, TE and a high flip angle greater than 60 degrees. To some degree, in phase sequences are more sensitive to detection of focal hepatic lesions than out of phase for evaluating reduced lesion-to-liver contrast, but the choice for a T1 gradient echo sequence is still based on field strength, advanced imaging techniques (breath hold imaging), and physician preference.
 
Images, Movies, Sliders:
 MRI Liver In Phase  Open this link in a new window
    
 
spacer

• View the DATABASE results for 'In Phase Image' (4).Open this link in a new window

 
Further Reading:
  News & More:
Direct Water and Fat Determination in Two-Point Dixon Imaging
April 2013   by scholarship.rice.edu    
MRI Resources 
PACS - Breast MRI - Process Analysis - MRI Technician and Technologist Career - Distributors - Portals
 
Line Shape
 
Distribution of the relative strength of resonance as a function of frequency, which establishes a particular spectral line. Common line shapes are Lorentzian and Gaussian.
spacer

• View the DATABASE results for 'Line Shape' (4).Open this link in a new window

Searchterm 'Spectra' was also found in the following services: 
spacer
News  (6)  Resources  (28)  
 
Localized Magnetic Resonance
 
(LMR) A particular technique for obtaining NMR spectra, for example, of phosphorus, from a limited region by creating a sensitive volume with inhomogeneous applied gradient magnetic fields, which may be enhanced with the use of surface coils.
spacer
Searchterm 'Spectra' was also found in the following service: 
spacer
Ultrasound  (29) Open this link in a new window
Magic Angle Effect (Artifact)InfoSheet: - Artifacts - 
Case Studies, 
Reduction Index, 
etc.MRI Resource Directory:
 - Artifacts -
 
Quick Overview
Artifact Information
NAME
Magic angle
DESCRIPTION
Increase of the T2 time, bright signal in tendons
REASON
Angle about 55° to the main magnetic field
HELP
Angle not about 55°
The magic angle is a precisely defined angle, the value is approximately 54.7°. Hence, two nuclei with a dipolar coupling vector at an angle of approximately 54.7° to a strong external magnetic field have zero dipolar coupling.
Magic angle spinning is a technique in solid-state NMR spectroscopy, which employs this principle to remove or reduce dipolar couplings, thereby increasing spectral resolution. In MRI, the magic angle effect visualizes as bright spots through an increased T2 time on short echo time (TE) images, for e.g. collagen fibers of tendons and ligaments, which are oriented at the magic angle of approximately 54.7° to the magnetic field.
mri safety guidance
Image Guidance
Take care that tendons and ligaments are not oriented at about a 54.7° angle to the main magnetic field.
spacer
 
Further Reading:
  Basics:
Magic angle
   by en.wikipedia.org    
Magic Angle Effects
   by www.mritutor.org    
MRI Resources 
Stent - MRA - Abdominal Imaging - Homepages - Safety pool - Diffusion Weighted Imaging
 
previous      26 - 30 (of 49)     next
Result Pages : [1 2]  [3 4 5 6 7 8 9 10]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



New acceleration techniques will :
reduce scan times 
cause artifacts 
increase expenses 
be useful if you have a lot of experience 
doesn't do much 
never heard of 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 18 May 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]