Magnetic Resonance - Technology Information Portal Welcome to MRI Technology
Info
  Sheets


Out-
      side
 



 
 'Device Information' 
SEARCH FOR    
 
  2 3 5 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Result : Searchterm 'Device Information' found in 0 term [] and 70 definitions []
previous     16 - 20 (of 70)     next
Result Pages : [1 2 3 4 5 6 7 8 9 10 11 12 13 14]
Searchterm 'Device Information' was also found in the following services: 
spacer
News  (2)  Resources  (4)  
 
Intera 0.5T™InfoSheet: - Devices -
Intro, 
Types of Magnets, 
Overview, 
etc.MRI Resource Directory:
 - Devices -
 
From Philips Medical Systems; www.medical.philips.com/de/products/mri/products/ this low field MRI system of the Intera-family is onto diagnostic safety and flexibility aligned - cost effective and with high patient acceptance.

Device Information and Specification
CLINICAL APPLICATION Whole body
CONFIGURATION Short bore compact
SURFACE COILS Standard: head, body, C1, C3; Optional: Small joint, flex-E, flex-R, endocavitary (L and S), dual TMJ, knee, neck, T/L spine, breast; Optional phased array: Spine, pediatric, 3rd party connector, Flex-S-M-L, flex body, flex cardiac, neuro-vascular, head
SPECTROSCOPY No
SYNCHRONIZATION ECG/peripheral: Optional/yes, respiratory gating
PULSE SEQUENCES SE, Modified-SE (TSE), DAVE, STIR, FLAIR, SPIR, MTC, Dynamic, Keyhole, CLEAR, Q Flow, Balanced FFE, Multi Chunk 3D, Multi Stack 3D, FFE-EPI, SE-EPI, IR-EPI, GRASE, Diffusion Imaging, Perfusion Imaging;; Angiography: Inflow MRA, TONE, PCA, CE MRA
IMAGING MODES Single Slice 2D , Multi Single Slice 2D, Multi Slice 2D, 3D, Multi Chunk 3D, Multi Stack 3D
TR Min. 2.9 (Omni) msec
TE Min. 1.0 (Omni) msec
SINGLE/MULTI SLICE RapidView Recon. greater than 500 @ 256 Matrix
FOV Max. 53 cm
SLICE THICKNESS 0.1 mm (Omni)
DISPLAY MATRIX 128 x 128, 256 x 256,512 x 512,1024 x 1024
MEASURING MATRIX Variable in 1% increments
PIXEL INTENSITY Lum.: 120 cd/m2; contrast: 150:1
SPATIAL RESOLUTION Variable (op. param. depend.)
MAGNET TYPE Superconducting
BORE DIAMETER
or W x H
60 x 60 cm
MAGNET WEIGHT 2500 kg
H*W*D 240 x 188 x 157 cm
POWER REQUIREMENTS 380/400 V
COOLING SYSTEM TYPE
CRYOGEN USE 0.03 L/hr helium
FIELD STRENGTH 0.5 T
STRENGTH 23 mT/m (Omni)
5-GAUSS FRINGE FIELD 2.1 m / 2.8 m
SHIMMING Passive and dynamic
spacer
MRI Resources 
Databases - MRI Technician and Technologist Jobs - RIS - Stimulator pool - Corporations - Mobile MRI Rental
 
Intera 1.0T™InfoSheet: - Devices -
Intro, 
Types of Magnets, 
Overview, 
etc.MRI Resource Directory:
 - Devices -
 
From Philips Medical Systems;
www.medical.philips.com/de/products/mri/products/ the Intera-family offers with this mid field system maximum efficiency, flexibility and performance. All Philips MR products contain SENSE (coil SENSitivity Encoding) technology - that increases scanning speed.

Device Information and Specification
CLINICAL APPLICATION Whole body
CONFIGURATION Short bore compact
SURFACE COILS Standard: head, body, C1, C3; Optional: Small joint, flex-E, flex-R, endocavitary (L and S), dual TMJ, knee, neck, T/L spine, breast; Optional phased array: Spine, pediatric, 3rd party connector, Optional SENSE Coils: Flex-S-M-L, Flex Body, Flex Cardiac,
SPECTROSCOPY Optional
SYNCHRONIZATION ECG/peripheral: Optional/yes, respiratory gating
PULSE SEQUENCES SE, Modified-SE, IR (T1, T2, PD), STIR, FLAIR, SPIR, FFE, T1-FFE, T2-FFE, Balanced FFE, TFE, Balanced TFE, Dynamic, Keyhole, 3D, Multi Chunk 3D, Multi Stack 3D, K Space Shutter, MTC, TSE, Dual IR, DRIVE, EPI, Cine, 2DMSS, DAVE, Mixed Mode; Angiography: Inflow MRA, TONE, PCA, CE MRA
IMAGING MODES Single Slice 2D , Multi Single Slice 2D, Multi Slice 2D, 3D, Multi Chunk 3D, Multi Stack 3D
TR Min. 2.9 (Omni) msec, 1.6 (Power) msec
TE Min. 1.0 (Omni) msec, 0.7 (Power) msec
SINGLE/MULTI SLICE RapidView Recon. greater than 500 @ 256 Matrix
FOV Max. 53 cm
SLICE THICKNESS 0.1 mm(Omni), 0.05 mm (Power)
DISPLAY MATRIX 128 x 128, 256 x 256,512 x 512,1024 x 1024 (64 for Bold img)
MEASURING MATRIX Variable in 1% increments
PIXEL INTENSITY Lum.: 120 cd/m2; contrast: 150:1
SPATIAL RESOLUTION Variable (op. param. depend.)
MAGNET TYPE Superconducting
BORE DIAMETER
or W x H
60 x 60 cm
MAGNET WEIGHT 2700 kg
H*W*D 240 x 188 x 157 cm
POWER REQUIREMENTS 380/400 V
COOLING SYSTEM TYPE
CRYOGEN USE 0.03 L/hr helium
FIELD STRENGTH 1.0 T
STRENGTH 23 mT/m (Omni), 30 (Power) mT/m
5-GAUSS FRINGE FIELD 2.3 m / 3.3 m
SHIMMING Passive and dynamic
spacer

• View the DATABASE results for 'Intera 1.0T™' (2).Open this link in a new window

MRI Resources 
Quality Advice - Liver Imaging - Developers - MRI Accidents - Image Quality - NMR
 
Intera 1.5T™InfoSheet: - Devices -
Intro, 
Types of Magnets, 
Overview, 
etc.MRI Resource Directory:
 - Devices -
 
From Philips Medical Systems;
www.medical.philips.com/de/products/mri/products/ the Intera-family offers with this member a wide range of possibilities, efficiency and a ergonomic and intuitive serving-platform. Also available as Intera CV for cardiac and Intera I/T for interventional MR procedures.
The scanners are also equipped with SENSE technology, which is essential for high-quality contrast enhanced magnetic resonance angiography, interactive cardiac MR and diffusion tensor imaging (DTI) fiber tracking.
The increased accuracy and clarity of MR scans obtained with this technology allow for faster and more accurate diagnosis of potential problems like patient friendliness and expands the breadth of applications including cardiology, oncology and interventional MR.

Device Information and Specification
CLINICAL APPLICATION Whole body
CONFIGURATION Short bore compact
SURFACE COILS Standard: head, body, C1, C3; Optional: Small joint, flex-E, flex-R, endocavitary (L and S), dual TMJ, knee, neck, T/L spine, breast; Optional phased array: Spine, pediatric, 3rd party connector; Optional SENSE coils: Flex-S-M-L, flex body, flex cardiac
SPECTROSCOPY Optional
SYNCHRONIZATION ECG/peripheral: Optional/yes, respiratory gating
PULSE SEQUENCES SE, Modified-SE (TSE), IR (T1, T2, PD), STIR, FLAIR, SPIR, FFE, T1-FFE, T2-FFE, Balanced FFE, TFE, Balanced TFE, Dynamic, Keyhole, 3D, Multi Chunk 3D, Multi Stack 3D, K Space Shutter, MTC, TSE, Dual IR, DRIVE, EPI, Cine, 2DMSS, DAVE, Mixed Mode; Angiography: PCA, MCA, Inflow MRA, CE
IMAGING MODES Single Slice 2D , Multi Single Slice 2D, Multi Slice 2D, 3D, Multi Chunk 3D, Multi Stack 3D
TR 2.9 (Omni), 1.6 (Power), 1.6 (Master/Expl) msec
TE 1.0 (Omni), 0.7 (Power), 0.5 (Master/Expl) msec
SINGLE/MULTI SLICE RapidView Recon. greater than 500 @ 256 Matrix
FOV Max. 53 cm
SLICE THICKNESS 0.1 mm(Omni), 0.05 mm (Pwr/Mstr/Expl)
DISPLAY MATRIX 128 x 128, 256 x 256,512 x 512,1024 x 1024 (64 for BOLD img.)
MEASURING MATRIX Variable in 1% increments
PIXEL INTENSITY Lum.: 120 cd/m2; contrast: 150:1
SPATIAL RESOLUTION Variable (op. param. depend.)
MAGNET TYPE Superconducting
BORE DIAMETER
or W x H
60 cm diameter (patient)
MAGNET WEIGHT 2900 kg
H*W*D 240 x 188 x 157 cm
POWER REQUIREMENTS 380/400 V
COOLING SYSTEM TYPE
CRYOGEN USE 0.03 L/hr helium
FIELD STRENGTH 1.5 T
STRENGTH 30 mT/m
5-GAUSS FRINGE FIELD 2.4 m / 3.8 m
SHIMMING Passive and dynamic
spacer

• View the DATABASE results for 'Intera 1.5T™' (2).Open this link in a new window

Searchterm 'Device Information' was also found in the following services: 
spacer
News  (2)  Resources  (4)  
 
Intera 3.0T™InfoSheet: - Devices -
Intro, 
Types of Magnets, 
Overview, 
etc.MRI Resource Directory:
 - Devices -
 
From Philips Medical Systems;
www.medical.philips.com/de/products/mri/products/ the Intera 3 T high field system, the first with a compact magnet, which is built on the same platform as the 1.5 T, is targeted to high-end neurological, orthopedic and cardiovascular imaging applications with maximum patient comfort and acceptance without compromising image quality and clinical performance. Useable for clinical routine and research. The Intera systems offer diffusion tensor imaging (DTI) fiber tracking that measures movement of water in the brain and can therefore detect areas of the brain where normal movement of water is disrupted.

Device Information and Specification
CLINICAL APPLICATION Whole body
CONFIGURATION Short bore compact
SURFACE COILS Standard: head, body, C1, C3; Optional: Small joint, flex-E, flex-R, endocavitary (L and S), dual TMJ, knee, neck, T/L spine, breast; Optional phased array: spine;; Optional SENSE coils: Flex body, flex cardiac, neuro-vascular, head
SPECTROSCOPY Optional
SYNCHRONIZATION ECG/peripheral: Optional/yes, respiratory gating
PULSE SEQUENCES SE, Modified-SE, IR (T1, T2, PD), STIR, FLAIR, SPIR, FFE, T1-FFE, T2-FFE, Balanced FFE, TFE, Balanced TFE, Dynamic, Keyhole, 3D, Multi Chunk 3D, Multi Stack 3D, K Space Shutter, MTC, TSE, Dual IR, DRIVE, EPI, Cine, 2DMSS, DAVE, Mixed Mode; Angiography: Inflow MRA, TONE, PCA, CE MRA
IMAGING MODES Single Slice 2D , Multi Single Slice 2D, Multi Slice 2D, 3D, Multi Chunk 3D, Multi Stack 3D
TR Min. 1.6 (Master) msec
TE Min. 0.5 (Master) msec
SINGLE/MULTI SLICE RapidView Recon. greater than 500 @ 256 Matrix
FOV Max. 53 cm
SLICE THICKNESS 0.1 mm (Omni), 0.05 mm (Power)
DISPLAY MATRIX 128 x 128, 256 x 256,512 x 512,1024 x 1024 (64 for Bold img)
MEASURING MATRIX Variable in 1% increments
PIXEL INTENSITY Lum.: 120 cd/m2; contrast: 150:1
SPATIAL RESOLUTION Variable (op. param. depend.)
MAGNET TYPE Superconducting
BORE DIAMETER
or W x H
60 x 60 cm
MAGNET WEIGHT 5500 kg
H*W*D 240 x 188 x 157 cm
POWER REQUIREMENTS 380/400 V
COOLING SYSTEM TYPE
CRYOGEN USE 0.07 L/hr helium
FIELD STRENGTH 3 T
STRENGTH 30 (Master) mT/m
5-GAUSS FRINGE FIELD 3.0 m / 5.2 m
SHIMMING Passive and dynamic
spacer

• View the DATABASE results for 'Intera 3.0T™' (2).Open this link in a new window

MRI Resources 
Patient Information - Image Quality - Knee MRI - Colonography - Pediatric and Fetal MRI - MR Myelography
 
Intera Achieva 1.5T™InfoSheet: - Devices -
Intro, 
Types of Magnets, 
Overview, 
etc.MRI Resource Directory:
 - Devices -
 
From Philips Medical Systems;
www.medical.philips.com/main/products/mri/products/intera_achieva/ The clinical capabilities of MR will further expand. Inside and out, the Achieva is a friendly, open system designed for optimal patient comfort and maximized workflow with high functionality. The Achieva 1.5T can be upgraded to Achieva I/T, with three configurations optimized for MR guided interventions and therapy:
Achieva I/T
Achieva I/T Neurosurgery
Achieva I/T Cardiovascular (or XMR - combining an Achieva 1.5T CV system and an X-Ray system)


Device Information and Specification
CLINICAL APPLICATION Whole body
CONFIGURATION Short bore compact
SURFACE COILS Standard: Head, body, C1, C3; Optional: Small joint, flex-E, flex-R, endocavitary (L and S), dual TMJ, knee, neck, T/L spine, breast; optional phased array: Spine, pediatric, 3rd party connector; Optional SENSE™ coils for all applications
SPECTROSCOPY Optional
SYNCHRONIZATION ECG/peripheral: Optional/yes, respiratory gating
PULSE SEQUENCES SE, Modified-SE, IR (T1, T2, PD), STIR, FLAIR, SPIR, FFE, T1-FFE, T2-FFE, Balanced FFE, TFE, Balanced TFE, Dynamic, Keyhole, 3D, Multi Chunk 3D, Multi Stack 3D, K Space Shutter, MTC, TSE, Dual IR, DRIVE, EPI, Cine, 2DMSS, DAVE, Mixed Mode; Angiography: Inflow MRA, TONE, PCA, CE MRA
IMAGING MODES Single Slice 2D , Multi Single Slice 2D, Multi Slice 2D, 3D, Multi Chunk 3D, Multi Stack 3D
FOV Over 40 cm
SLICE THICKNESS 0.05 mm
DISPLAY MATRIX 128 x 128, 256 x 256,512 x 512,1024 x 1024 (64 for Bold img)
MEASURING MATRIX Variable in 1% increments
PIXEL INTENSITY Lum.: 120 cd/m2; contrast: 150:1
SPATIAL RESOLUTION Variable (op. param. depend.)
MAGNET TYPE Superconducting
BORE DIAMETER
or W x H
60 x 60 cm
POWER REQUIREMENTS 380/400 V
CRYOGEN USE 0.03 L/hr helium
FIELD STRENGTH 1.5 T
STRENGTH up to 66 mT/m
5-GAUSS FRINGE FIELD 2.4 m / 3.8 m
SHIMMING Passive and dynamic
spacer

• View the DATABASE results for 'Intera Achieva 1.5T™' (2).Open this link in a new window

MRI Resources 
Developers - MRI Training Courses - Coils - MRI Technician and Technologist Jobs - Stent - Movies
 
previous      16 - 20 (of 70)     next
Result Pages : [1 2 3 4 5 6 7 8 9 10 11 12 13 14]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?  



In 2075 (after about 100 years of ...) the MRI scan will be :
obsolete 
done with handheld probe 
done at home (app, ...) 
a 3 second walk through 
daily done 
replaced by something much ... 

Look
      Ups





Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • US-TIP • The-Medical-Market
Copyright © 2003 - 2016 SoftWays. All rights reserved. [ 21 January 2017]
Terms of Use | Privacy Policy | Advertising
 [last update: 2017-01-13 03:47:00]