Magnetic Resonance - Technology Information Portal Welcome to MRI Technology
Info
  Sheets


Out-
      side
 



 
 'Device Information' 
SEARCH FOR    
 
  2 3 5 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Result : Searchterm 'Device Information' found in 0 term [] and 70 definitions []
previous     61 - 65 (of 70)     next
Result Pages : [1 2 3 4 5 6 7 8 9 10 11 12 13 14]
Searchterm 'Device Information' was also found in the following services: 
spacer
News  (2)  Resources  (4)  
 
Signa OpenSpeed™InfoSheet: - Devices -
Intro, 
Types of Magnets, 
Overview, 
etc.MRI Resource Directory:
 - Devices -
 
From GE Healthcare;
www.gehealthcare.com/usen/mr/open_speed/index.html a friendly and less confining appearance targets the 7% of individuals who refuse to have an MRI because of claustrophobia. This open MRI system is also up to three times faster than other scanners, therefore the Signa OpenSpeed™ reducing exam time and scheduling issues. In addition, a swing table provides better access and supports up to 500 pounds.

Device Information and Specification
CLINICAL APPLICATION Whole body
CONFIGURATION Open MRI
SURFACE COILS Integrated transmit and receive body coil;; 4 channel head array, 8 channel CTL array, 2 channel shoulder array, 3 channel large extremity array, 3 channel small extremity array, 4 channel foot array, 3 channel wrist array, 4 channel breast array
SPECTROSCOPY No
SYNCHRONIZATION Standard cardiac gating, ECG/peripheral, respiratory gating
PULSE SEQUENCES Standard: SE, IR, 2D/3D GRE and SPGR, Angiography: 2D/3D TOF, 2D/3D Phase Contrast;; 2D/3D FSE, 2D/3D FGRE and FSPGR, SSFP, FLAIR, EPI, optional: 2D/3D Fiesta, FGRET, Spiral, Tensor
IMAGING MODES Localizer, single slice, multislice, volume, fast, POMP, multi slab, cine
TR 1.3 to 12000 msec in increments of 1 msec
TE 0.4 to 2000 msec in increments of 1 msec
SINGLE/MULTI SLICE Simultaneous scan and reconstruction;; 100 images/second with Reflex 100
FOV 1cm to 40 cm continuous
SLICE THICKNESS 2D: 0.8mm - 20mm 3D: 0.1mm - 20mm
DISPLAY MATRIX 1280 x 1024
MEASURING MATRIX 128x512 steps 32 phase//freq.
PIXEL INTENSITY 256 gray levels
SPATIAL RESOLUTION 0.08 mm; 0.02 mm optional
MAGNET TYPE Superconducting
BORE DIAMETER
or W x H
175 x 85 x 447 cm
MAGNET WEIGHT 8256 kg
H*W*D 530 x 175 x 250 cm
POWER REQUIREMENTS 200 - 480, 3-phase
COOLING SYSTEM TYPE Liquid helium
CRYOGEN USE 0.03 L/hr, holds 300 L
FIELD STRENGTH 0.7 T
STRENGTH 25 mT/m
5-GAUSS FRINGE FIELD 4.7 m/ 3.8 m
SHIMMING Computerized passive shimming during magnet setup, autoshim per series with automatic table motion to magnet isocenter for each prescription
spacer
 
Further Reading:
  News & More:
MR Surgical Suite, Improving surgical procedure quality (.pdf)
   by www3.gehealthcare.com    
MRI Resources 
Shielding - Portals - Breast Implant - Hospitals - Devices - Corporations
 
Signa Ovation™InfoSheet: - Devices -
Intro, 
Types of Magnets, 
Overview, 
etc.MRI Resource Directory:
 - Devices -
 
From GE Healthcare;
www.gehealthcare.com/usen/mr/ovation/index.html the Signa Ovation™ is a patient-friendly open MRI scanner designed not only to handle a typical patient mix, but to accommodate larger patients, patients who are claustrophobic, and others who have difficulty tolerating the close quarters of conventional MR machines.
Device Information and Specification
CLINICAL APPLICATION Whole body
CONFIGURATION Open MRI
SURFACE COILS Integrated transmit and receive body coil;; head coil, 4 channel neurovascular array, 8 channel CTL array, 2 channel shoulder array, 3 channel large extremity array, 3 channel small extremity array, 4 channel foot array, 3 channel wrist array
SPECTROSCOPY No
SYNCHRONIZATION Standard cardiac gating, ECG/peripheral, respiratory gating
PULSE SEQUENCES Standard: SE, IR, 2D/3D GRE and SPGR, 2D/3D TOF, 2D/3D FSE, 2D/3D FGRE and FSPGR, SSFP, FLAIR, EPI, optional: 2D/3D Fiesta, true chem sat, fat/water separation, single shot diffusion EPI, line scan diffusion
IMAGING MODES Localizer, single slice, multislice, volume, fast, POMP, multi slab, cine, slice and frequency zip, extended dynamic range, tailored RF
TR 1.3 to 12000 msec in increments of 1 msec
TE 0.4 to 2000 msec in increments of 1 msec
SINGLE/MULTI SLICE Simultaneous scan and reconstruction;; 80 images/second reconstruction
FOV 3cm to 40 cm continuous
SLICE THICKNESS 2D: 1.4mm - 20mm 3D: 0.2mm - 20mm
DISPLAY MATRIX 1280 x 1024
MEASURING MATRIX 128x512 steps 32 phase//freq.
PIXEL INTENSITY 256 gray levels
SPATIAL RESOLUTION 0.08 mm; 0.02 mm optional
MAGNET TYPE Permanent
BORE DIAMETER
or W x H
175 x 85 x 447 cm
MAGNET WEIGHT 19200 kg
H*W*D 530 x 175 x 250 cm
POWER REQUIREMENTS 200 - 480, 3-phase
GRADIENT COOLING None
FIELD STRENGTH 0.35 T
MAX. GRADIENT AMPLITUDE 19 mT/m
5-GAUSS FRINGE FIELD 2.5 m/2.5 m
SHIMMING Computerized passive shimming during magnet setup, autoshim per series with automatic table motion to magnet isocenter for each prescription
spacer

• View the DATABASE results for 'Signa Ovation™' (2).Open this link in a new window

MRI Resources 
Devices - Education - Fluorescence - Societies - Collections - MRA
 
Signa Profile™InfoSheet: - Devices -
Intro, 
Types of Magnets, 
Overview, 
etc.MRI Resource Directory:
 - Devices -
 
From GE Healthcare;
www.gehealthcare.com/usen/mr/profilei/index.html the New Signa Profile/i is a patient friendly open MRI system that virtually eliminates patient anxiety and claustrophobia, without compromising diagnostic utility.
Device Information and Specification
CLINICAL APPLICATION Whole body
CONFIGURATION Open MRI
SURFACE COILS Integrated transmit body coil, body flex sizes: M, L, XL, quadrature, head coil quadrature, 4 channel neurovascular array, 8 channel CTL array, quad. c-spine, 2 channel shoulder array, extremity coil, 3 channel wrist array, 4 channel breast array, 6, 9, 11 inch general purpose loop coils
SPECTROSCOPY No
SYNCHRONIZATION Standard cardiac gating, ECG/peripheral, respiratory gating
PULSE SEQUENCES Standard: SE, IR, 2D/3D GRE and SPGR, Angiography: 2D/3D TOF, 2D/3D phase contrast;; 2D/3D FSE, 2D/3D FRFSE, FGRE and FSPGR, SSFP, FLAIR, EPI, optional: 2D/3D Fiesta, fat/water separation, T1 FLAIR
IMAGING MODES Localizer, single slice, multislice, volume, fast, POMP, multi slab, cine, slice and frequency zip, extended dynamic range, tailored RF
TR 6 to 12000 msec in increments of 1 msec
TE 1.3 to 2000 msec in increments of 1 msec
SINGLE/MULTI SLICE Simultaneous scan and reconstruction;; 80 images/second reconstruction
FOV 3cm to 40 cm continuous
SLICE THICKNESS 2D: 2.7mm - 20mm 3D: 0.2mm - 5mm
DISPLAY MATRIX 1280 x 1024
MEASURING MATRIX 128x512 steps 32 phase//freq.
PIXEL INTENSITY 256 gray levels
SPATIAL RESOLUTION 0.08 mm; 0.02 mm optional
MAGNET TYPE Permanent
BORE DIAMETER
or W x H
120 x 44 cm
MAGNET WEIGHT 10,000 kg w/gradient enclosure
H*W*D 147 x 214 x 193 cm
POWER REQUIREMENTS 200 - 480, 3-phase
COOLING SYSTEM TYPE None required
CRYOGEN USE
FIELD STRENGTH 0.2 T
STRENGTH 15 mT/m
5-GAUSS FRINGE FIELD 1.7 m/1.7 m
spacer

• View the DATABASE results for 'Signa Profile™' (2).Open this link in a new window

Searchterm 'Device Information' was also found in the following services: 
spacer
News  (2)  Resources  (4)  
 
Signa SP 0.5T™ Open ConfigurationInfoSheet: - Devices -
Intro, 
Types of Magnets, 
Overview, 
etc.MRI Resource Directory:
 - Devices -
 
From GE Healthcare;
www.gehealthcare.com/usen/mr/index.html The Signa SP 0.5T™ is an open MRI magnet that is designed for use in interventional radiology and intra-operative imaging. The vertical gap configuration increases patient positioning options, improves patient observation, and allows continuous access to the patient during imaging. The magnet enclosure also incorporates an intercom, patient observation video camera, laser patient alignment lights, and task lighting in the imaging volume.

Device Information and Specification
CLINICAL APPLICATION Whole body
CONFIGURATION Open
SURFACE COILS Integrated transmit and receive body coil;; optional rotational body coil, head;; other coils optional; open architecture makes system compatible with a wide selection of coilsarray
SPECTROSCOPY No
SYNCHRONIZATION Standard cardiac gating, ECG/peripheral, respiratory gating
PULSE SEQUENCES Standard: SE, IR, 2D/3D GRE and SPGR, 2D/3D TOF, 2D/3D FSE, 2D/3D FGRE and FSPGR, SSFP, FLAIR, EPI, optional: 2D/3D Fiesta, true chem sat, fat/water separation, single shot diffusion EPI
IMAGING MODES Localizer, single slice, multislice, volume, fast, POMP, multi slab, cine, slice and frequency zip, extended dynamic range, tailored RF
TR 1.3 to 12000 msec in increments of 1 msec
TE 0.4 to 2000 msec in increments of 1 msec
FOV 3cm to 40 cm continuous
SLICE THICKNESS 2D: 1.4mm - 20mm 3D: 0.2mm - 20mm
DISPLAY MATRIX 1280 x 1024
MEASURING MATRIX 128x512 steps 32 phase//freq.
PIXEL INTENSITY 256 gray levels
MAGNET TYPE Superconducting
BORE DIAMETER
or W x H
60 x 58 cm
POWER REQUIREMENTS 200 - 480, 3-phase
COOLING SYSTEM TYPE Liquid helium
CRYOGEN USE 0.03 L/hr, holds 300 L
FIELD STRENGTH 0.5 T
STRENGTH 12 mT/m
SHIMMING Active
spacer

• View the DATABASE results for 'Signa SP 0.5T™ Open Configuration' (2).Open this link in a new window

 
Further Reading:
  News & More:
MR Surgical Suite, Improving surgical procedure quality (.pdf)
   by www3.gehealthcare.com    
MRI Resources 
Education - Chemistry - Safety Products - Societies - Artifacts - Implant and Prosthesis
 
Ultra™InfoSheet: - Devices -
Intro, 
Types of Magnets, 
Overview, 
etc.MRI Resource Directory:
 - Devices -
 
medical.toshiba.com/clinical/radiology/ultra.htm From Toshiba America Medical Systems Inc.;
the Ultra™ system was developed to help healthcare providers be more competitive by delivering greater patient comfort and a broad range of clinical capabilities, says Anita Bowler, product manager, MRI Business Unit, Toshiba America Medical Systems Inc With its unique, powerful gradient technology, the Ultra™ performs advanced clinical studies and consistently provides high-resolution images that are typically associated with high field MRI systems. At the same time, the Ultra™ offers a truly open feeling that makes patients more relaxed, especially those with claustrophobic tendencies.

Device Information and Specification
CLINICAL APPLICATION Whole Body
CONFIGURATION Open MRI
SURFACE COILS Quadrature, solenoid and multi-channel configurations
PULSE SEQUENCES SE, FE, IR, FastSE, FastIR, FastFLAIR, Fast STIR, FastFE, FASE, Hybrid EPI, Multi Shot EPI, Single shot EPI diffusion, True SSFP, SuperFASE; Angiography: 2D(gate/non-gate)/3D TOF, SORS-STC, Black Blood MRA
MAGNET TYPE Superconducting
POWER REQUIREMENTS 380/400/415/440/480 V
COOLING SYSTEM TYPE Cryogenless
FIELD STRENGTH 0.35 T
STRENGTH 25 mT/m
SHIMMING Passive, active
spacer
MRI Resources 
Functional MRI - Breast Implant - Stimulator pool - Jobs - DICOM - MRI Centers
 
previous      61 - 65 (of 70)     next
Result Pages : [1 2 3 4 5 6 7 8 9 10 11 12 13 14]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?  



In 2020 your scanner will probably work with a field strength of :
lower 
1T 
1.5T 
2T 
3T 
7T 
higher 

Look
      Ups





Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • US-TIP • The-Medical-Market
Copyright © 2003 - 2016 SoftWays. All rights reserved. [ 22 January 2017]
Terms of Use | Privacy Policy | Advertising
 [last update: 2017-01-13 03:47:00]