Magnetic Resonance - Technology Information Portal Welcome to MRI Technology
Info
  Sheets


Out-
      side
 



 
 '3D SPGR' 
SEARCH FOR    
 
  2 3 5 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Result : Searchterm '3D SPGR' found in 0 term [] and 0 definition [], (+ 13 Boolean[] results
1 - 5 (of 13)     next
Result Pages : [1 2 3]
MRI Resources 
Image Quality - Sequences - Open Directory Project - Mobile MRI - Absorption and Emission - Cardiovascular Imaging
 
Fast Acquisition with Multiphase EFGRE3DInfoSheet: - Sequences - 
Intro, 
Overview, 
Types of, 
etc.
 
(FAME) The FAME MRI technique uses a 3dimensional fast SPGR pulse sequence to acquire high resolution images. With its short scan time, FAME is useful for dynamic liver imaging with multiple phases.
spacer
 
• Share the entry 'Fast Acquisition with Multiphase EFGRE3D':  Facebook  Twitter  LinkedIn  
MRI Resources 
Corporations - Universities - Used and Refurbished MRI Equipment - Cardiovascular Imaging - Collections - Hospitals
 
Fast Spoiled Grass Sequence with IR PreparationInfoSheet: - Sequences - 
Intro, 
Overview, 
Types of, 
etc.
 
(IR-FSPGR) This sequence uses an inversion pulse followed by a spoiled low flip angle and short TR gradient echo train to collect all partition data. The 3D-IR-FSPGR uses centric ordering of Gz. The selected TI is also the effective TI. The centric reordering strategy can lead to image blurring if a steady state is not achieved quickly with low flip angles (less than 20°).
spacer
MRI Resources 
Breast MRI - MRI Technician and Technologist Schools - Cochlear Implant - Equipment - Software - Libraries
 
Signa Infinity 1.5T™ with ExciteInfoSheet: - Devices -
Intro, 
Types of Magnets, 
Overview, 
etc.MRI Resource Directory:
 - Devices -
 
From GE Healthcare;
www.gehealthcare.com/usen/mr/s_excite15/index.html 'EXCITE technology has the potential to open the door to new imaging techniques and clinical applications, leaping beyond conventional two and three-dimensional MRI to true 4D imaging that will improve the diagnosis of disease throughout the human body from head to foot.' Robert R. Edelman, M.D., Professor of Radiology at Northwestern University Medical School and Chairman, Department of Radiology, at Evanston Northwestern Healthcare.

Device Information and Specification
CLINICAL APPLICATION Whole body
CONFIGURATION Short bore
SURFACE COILS Head and body coil standard; all other coils optional; open architecture makes system compatible with a wide selection of coils
SPECTROSCOPY Optional 2D/3D brain and prostate
SYNCHRONIZATION ECG/peripheral, respiratory gating, (SmartPrep, SmartStep)
PULSE SEQUENCES Standard: SE, IR, 2D/3D GRE and SPGR, Angiography: 2D/3D TOF, 2D/3D Phase Contrast;; 2D/3D FSE, 2D/3D FGRE and FSPGR, SSFP, FLAIR, EPI, optional: 2D/3D Fiesta, FGRET, Spiral, Tensor
IMAGING MODES Localizer, single slice, multislice, volume, fast, POMP, multi slab, cine
TR 1.3 to 12000 msec in increments of 1 msec
TE 0.4 to 2000 msec in increments of 1 msec
SINGLE/MULTI SLICE Simultaneous scan and reconstruction;; up to 200 or 400 images per second
FOV 1 cm to 48 cm continuous
SLICE THICKNESS 2D 0.7 mm to 20 mm; 3D 0.1 mm to 5 mm
DISPLAY MATRIX 1028 x 1024
MEASURING MATRIX 128x512 steps 32 phase encode
PIXEL INTENSITY 256 gray levels
SPATIAL RESOLUTION 0.08 mm; 0.02 mm optional
MAGNET TYPE Superconducting
BORE DIAMETER 60 cm
MAGNET WEIGHT 3863 kg
H*W*D 172 x 208 x 216 cm
POWER REQUIREMENTS 480 or 380/415
COOLING SYSTEM TYPE Closed-loop water-cooled gradient
CRYOGEN USE, L/hr less than 0.03 L/hr liquid helium
FIELD STRENGTH 1.5 T
STRENGTH SmartSpeed 23 mT/m, HiSpeed Plus 33 mT/m, EchoSpeed Plus 33 mT/m
5-GAUSS FRINGE FIELD 4.0 m x 2.8 m axial x radial
SHIMMING Active
spacer

• View the DATABASE results for 'Signa Infinity 1.5T™ with Excite' (2).Open this link in a new window

MRI Resources 
Shielding - Breast Implant - RIS - MRI Technician and Technologist Schools - Libraries - Brain MRI
 
Signa Profile™InfoSheet: - Devices -
Intro, 
Types of Magnets, 
Overview, 
etc.MRI Resource Directory:
 - Devices -
 
From GE Healthcare;
www.gehealthcare.com/usen/mr/profilei/index.html the New Signa Profile/i is a patient friendly open MRI system that virtually eliminates patient anxiety and claustrophobia, without compromising diagnostic utility.
Device Information and Specification
CLINICAL APPLICATION Whole body
CONFIGURATION Open MRI
SURFACE COILS Integrated transmit body coil, body flex sizes: M, L, XL, quadrature, head coil quadrature, 4 channel neurovascular array, 8 channel CTL array, quad. c-spine, 2 channel shoulder array, extremity coil, 3 channel wrist array, 4 channel breast array, 6, 9, 11 inch general purpose loop coils
SPECTROSCOPY No
SYNCHRONIZATION Standard cardiac gating, ECG/peripheral, respiratory gating
PULSE SEQUENCES Standard: SE, IR, 2D/3D GRE and SPGR, Angiography: 2D/3D TOF, 2D/3D phase contrast;; 2D/3D FSE, 2D/3D FRFSE, FGRE and FSPGR, SSFP, FLAIR, EPI, optional: 2D/3D Fiesta, fat/water separation, T1 FLAIR
IMAGING MODES Localizer, single slice, multislice, volume, fast, POMP, multi slab, cine, slice and frequency zip, extended dynamic range, tailored RF
TR 6 to 12000 msec in increments of 1 msec
TE 1.3 to 2000 msec in increments of 1 msec
SINGLE/MULTI SLICE Simultaneous scan and reconstruction;; 80 images/second reconstruction
FOV 3cm to 40 cm continuous
SLICE THICKNESS 2D: 2.7mm - 20mm 3D: 0.2mm - 5mm
DISPLAY MATRIX 1280 x 1024
MEASURING MATRIX 128x512 steps 32 phase//freq.
PIXEL INTENSITY 256 gray levels
SPATIAL RESOLUTION 0.08 mm; 0.02 mm optional
MAGNET TYPE Permanent
BORE DIAMETER
or W x H
120 x 44 cm
MAGNET WEIGHT 10,000 kg w/gradient enclosure
H*W*D 147 x 214 x 193 cm
POWER REQUIREMENTS 200 - 480, 3-phase
COOLING SYSTEM TYPE None required
CRYOGEN USE
FIELD STRENGTH 0.2 T
STRENGTH 15 mT/m
5-GAUSS FRINGE FIELD 1.7 m/1.7 m
spacer

• View the DATABASE results for 'Signa Profile™' (2).Open this link in a new window

MRI Resources 
Breast Implant - Spectroscopy pool - NMR - Societies - IR - Claustrophobia
 
Signa Ovation™InfoSheet: - Devices -
Intro, 
Types of Magnets, 
Overview, 
etc.MRI Resource Directory:
 - Devices -
 
From GE Healthcare;
www.gehealthcare.com/usen/mr/ovation/index.html the Signa Ovation™ is a patient-friendly open MRI scanner designed not only to handle a typical patient mix, but to accommodate larger patients, patients who are claustrophobic, and others who have difficulty tolerating the close quarters of conventional MR machines.
Device Information and Specification
CLINICAL APPLICATION Whole body
CONFIGURATION Open MRI
SURFACE COILS Integrated transmit and receive body coil;; head coil, 4 channel neurovascular array, 8 channel CTL array, 2 channel shoulder array, 3 channel large extremity array, 3 channel small extremity array, 4 channel foot array, 3 channel wrist array
SPECTROSCOPY No
SYNCHRONIZATION Standard cardiac gating, ECG/peripheral, respiratory gating
PULSE SEQUENCES Standard: SE, IR, 2D/3D GRE and SPGR, 2D/3D TOF, 2D/3D FSE, 2D/3D FGRE and FSPGR, SSFP, FLAIR, EPI, optional: 2D/3D Fiesta, true chem sat, fat/water separation, single shot diffusion EPI, line scan diffusion
IMAGING MODES Localizer, single slice, multislice, volume, fast, POMP, multi slab, cine, slice and frequency zip, extended dynamic range, tailored RF
TR 1.3 to 12000 msec in increments of 1 msec
TE 0.4 to 2000 msec in increments of 1 msec
SINGLE/MULTI SLICE Simultaneous scan and reconstruction;; 80 images/second reconstruction
FOV 3cm to 40 cm continuous
SLICE THICKNESS 2D: 1.4mm - 20mm 3D: 0.2mm - 20mm
DISPLAY MATRIX 1280 x 1024
MEASURING MATRIX 128x512 steps 32 phase//freq.
PIXEL INTENSITY 256 gray levels
SPATIAL RESOLUTION 0.08 mm; 0.02 mm optional
MAGNET TYPE Permanent
BORE DIAMETER
or W x H
175 x 85 x 447 cm
MAGNET WEIGHT 19200 kg
H*W*D 530 x 175 x 250 cm
POWER REQUIREMENTS 200 - 480, 3-phase
GRADIENT COOLING None
FIELD STRENGTH 0.35 T
MAX. GRADIENT AMPLITUDE 19 mT/m
5-GAUSS FRINGE FIELD 2.5 m/2.5 m
SHIMMING Computerized passive shimming during magnet setup, autoshim per series with automatic table motion to magnet isocenter for each prescription
spacer

• View the DATABASE results for 'Signa Ovation™' (2).Open this link in a new window

MRI Resources 
Diffusion Weighted Imaging - Services and Supplies - MRI Technician and Technologist Jobs - Health - Jobs pool - NMR
 
     1 - 5 (of 13)     next
Result Pages : [1 2 3]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?  



PET-MRI is :
a valuable new tool 
worth to develop more 
unnecessary 
too expensive 
only for research 
the replacement for PET-CT 
for vets only 

Look
      Ups





Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • US-TIP • The-Medical-Market
Copyright © 2003 - 2014 SoftWays. All rights reserved. [ 26 November 2014]
Terms of Use | Privacy Policy | Advertising