Turbo Spin Echo Turbo Factor
 
(TSE TF) The turbo factor is the number of echoes acquired after each excitation. This is a measure of the scan time acceleration, e.g. at turbo factor 3 the scan time is 3 times faster as a SE sequence with comparable parameters. In combination with profile order and effective echo time the TSE turbo factor controls the echo spacing.

See also Scan Time and Echo Spacing.
spacer
 
• Related Searches:
    • Number of Echoes
    • Radio Frequency Pulse
    • Fast Spin Echo
    • Echo Train Length
    • Scan Time
 
Further Reading:
  News & More:
Comparison of Fast Spin-Echo Versus Conventional Spin-Echo MRI forEvaluating Meniscal Tears
June 2005   by www.ajronline.org    
Searchterm 'Spin' was also found in the following services: 
spacer
Radiology  (12) Open this link in a new windowUltrasound  (2) Open this link in a new window
Fast Relaxation Fast Spin EchoInfoSheet: - Sequences - 
Intro, 
Overview, 
Types of, 
etc.
 
(FRFSE, FR-FSE) The fast relaxation fast spin echo sequence provides high signal intensity of fluids even with short repetition times, and can be used with parallel imaging techniques for short breath hold imaging or respiratory gating for free-breathing, high isotropic resolution MR imaging. After signal decay at the end of the echo train, a negative 90° pulse align spins with long T2 from the transverse plane to the longitudinal plane, leading to a much faster recovery of tissues with long T2 time to the equilibrium and thus better contrast between tissues with long and short T2.
Fast relaxation FSE has advantages also for volumetric imaging as the TR can be substantially reduced and thus the scan time. The sequence can be post processed with maximum intensity projection, surface or volume rendering algorithms to visualize anatomical details in brain or spine MRI. Cerebro spinal fluid pulsation artifacts, often problematic in the cervical or thoracic spine may be reduced by radial sampling, in particular when combined with acquisitions of the PROPELLER type.

See also Fast spin echo, Driven Equilibrium.
 
Images, Movies, Sliders:
 Shoulder Sagittal T2 FatSat FRFSE  Open this link in a new window
    

Courtesy of  Robert R. Edelman
 Shoulder Axial T2 FatSat FRFSE  Open this link in a new window
 Shoulder Coronal T2 FatSat FRFSE  Open this link in a new window
    

Courtesy of  Robert R. Edelman
 
spacer
MRI Resources 
Hospitals - Examinations - Quality Advice - Intraoperative MRI - PACS - Spectroscopy
 
Continuous Arterial Spin LabelingInfoSheet: - Sequences - 
Intro, 
Overview, 
Types of, 
etc.
 
(CASL) In order to take spins in a different magnetic state to that of the static tissue a train of RF pulses repeatedly saturates blood water spins flowing through the neck. The saturated (or 'labeled') spins flow into the brain and, assuming water is a freely diffusible tracer, exchange completely with brain tissue water, thus reducing the overall tissue magnetization. A steady state progresses where the regional magnetization in the brain is directly related to cerebral blood flow.
spacer
 
Further Reading:
  Basics:
Measuring Cerebral Blood Flow Using Magnetic Resonance Imaging Techniques
1999   by www.stanford.edu    
  News & More:
Non-invasive MRI technique distinguishes between Alzheimer's and frontotemporal dementia
Saturday, 18 June 2005   by www.eurekalert.org    
Searchterm 'Spin' was also found in the following services: 
spacer
News  (64)  Resources  (27)  Forum  (47)  
 
Driven Equilibrium Fast Spin EchoInfoSheet: - Sequences - 
Intro, 
Overview, 
Types of, 
etc.
 
(DE FSE) A fast spin echo sequence with application of a pulse, which sensitizes the sequence to variations in T2.
 
Images, Movies, Sliders:
 MRI of the Skull Base  Open this link in a new window
    
SlidersSliders Overview

 
spacer
 
Further Reading:
  News & More:
Metal Artefact Reduction
Thursday, 9 June 2011   by www.revisemri.com    
Searchterm 'Spin' was also found in the following services: 
spacer
Radiology  (12) Open this link in a new windowUltrasound  (2) Open this link in a new window
Cerebro Spinal Fluid Pulsation ArtifactInfoSheet: - Artifacts - 
Case Studies, 
Reduction Index, 
etc.MRI Resource Directory:
 - Artifacts -
 
Quick Overview
Artifact Information
NAME
Cerebro spinal fluid pulsation
DESCRIPTION
Ghosting
REASON
Inconsistencies in phase and amplitude
Pulsatile cerebro spinal fluid flow produces ghost artifacts that are superimposed in the image.
mri safety guidance
Image Guidance
Flow compensation should be used to reduce these artifacts. This applies an additional gradient to eliminate phase differences for both stationary and moving spins at the echo time. At TE no phase differences is measured. If flow compensation is applied and there are still flow artifacts, cardiac triggering is an additional option to reduce these artifacts.
See also Motion Artifact.
spacer

• View the DATABASE results for 'Cerebro Spinal Fluid Pulsation Artifact' (3).Open this link in a new window

MRI Resources 
Supplies - Mobile MRI - Databases - Knee MRI - PACS - Hospitals
 
previous      41 - 45 (of 317)     next
Result Pages : [1 2 3 4 5 6 7 8 9 10]  [11 12 13 14 15 16 17 18 19 20 ... ]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



New acceleration techniques will :
reduce scan times 
cause artifacts 
increase expenses 
be useful if you have a lot of experience 
doesn't do much 
never heard of 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 3 May 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]