ContrastForum -
related threads
 
Contrast is the relative difference of signal intensities in two adjacent regions of an image.
Due to the T1 and T2 relaxation properties in magnetic resonance imaging, differentiation between various tissues in the body is possible. Tissue contrast is affected by not only the T1 and T2 values of specific tissues, but also the differences in the magnetic field strength, temperature changes, and many other factors. Good tissue contrast relies on optimal selection of appropriate pulse sequences (spin echo, inversion recovery, gradient echo, turbo sequences and slice profile).
Important pulse sequence parameters are TR (repetition time), TE (time to echo or echo time), TI (time for inversion or inversion time) and flip angle. They are associated with such parameters as proton density and T1 or T2 relaxation times. The values of these parameters are influenced differently by different tissues and by healthy and diseased sections of the same tissue.
For the T1 weighting it is important to select a correct TR or TI. T2 weighted images depend on a correct choice of the TE. Tissues vary in their T1 and T2 times, which are manipulated in MRI by selection of TR, TI, and TE, respectively. Flip angles mainly affect the strength of the signal measured, but also affect the TR/TI/TE parameters.
Conditions necessary to produce different weighted images:
T1 Weighted Image: TR value equal or less than the tissue specific T1 time - TE value less than the tissue specific T2 time.
T2 Weighted Image: TR value much greater than the tissue specific T1 time - TE value greater or equal than the tissue specific T2 time.
Proton Density Weighted Image: TR value much greater than the tissue specific T1 time - TE value less than the tissue specific T2 time.

See also Image Contrast Characteristics, Contrast Reversal, Contrast Resolution, and Contrast to Noise Ratio.
 
Images, Movies, Sliders:
 Fetus (Brain) and Dermoid in Mother  Open this link in a new window
      

Courtesy of  Robert R. Edelman

 Circle of Willis, Time of Flight, MIP  Open this link in a new window
    
SlidersSliders Overview

 Anatomic MRI of the Knee 1  Open this link in a new window
    
SlidersSliders Overview

 Anatomic Imaging of the Liver  Open this link in a new window
      

 Brain MRI Inversion Recovery  Open this link in a new window
    
 
spacer
 
• Related Searches:
    • Brain MRI
    • Contrast Medium
    • Signal Intensity
    • Breast MRI
    • Inversion Time
 
Further Reading:
  Basics:
Magnetic resonance imaging
   by www.scholarpedia.org    
MRI's inside story
Thursday, 4 December 2003   by www.economist.com    
Image Characteristics and Quality
   by www.sprawls.org    
  News & More:
A natural boost for MRI scans
Monday, 21 October 2013   by www.eurekalert.org    
A groundbreaking new graphene-based MRI contrast agent
Friday, 8 June 2012   by www.nanowerk.com    
New MRI Chemical Offers Amazing Contrast
Friday, 22 January 2010   by news.softpedia.com    
Searchterm 'Resonance' was also found in the following services: 
spacer
Radiology  (15) Open this link in a new windowUltrasound  (32) Open this link in a new window
Contrast Enhanced MR VenographyInfoSheet: - Sequences - 
Intro, 
Overview, 
Types of, 
etc.MRI Resource Directory:
 - MRA -
 
(CEMRV) A 3D dynamic contrast enhanced magnetic resonance venogram with acquisition timing to account for the later arrival of the contrast agent in the venous system. The pulse sequence used, is an enhanced 3D fast gradient echo sequence, the same sequence that is used for MR angiography.

For Ultrasound Imaging (USI) see Venous Ultrasound at Medical-Ultrasound-Imaging.com.
 
Images, Movies, Sliders:
 CE-MRA of the Carotid Arteries Colored MIP  Open this link in a new window
    
SlidersSliders Overview

 PCA-MRA 3D Brain Venography Colored MIP  Open this link in a new window
    

 
spacer

• View the DATABASE results for 'Contrast Enhanced MR Venography' (3).Open this link in a new window

MRI Resources 
Guidance - Spectroscopy - Examinations - Case Studies - Software - Directories
 
Contrast to Noise Ratio
 
(CNR) In Magnetic Resonance Imaging MRI, Contrast to noise ratio is the relationship of signal intensity differences between two regions, scaled to image noise. Improving CNR increases perception of the distinct differences between two clinical areas of interest. A contrast to noise ratio is a summary of SNR and contrast. It is the difference in SNR between two relevant tissue types.
(A and B): CNR = SNRA - SNRB

See also Signal Intensity, Signal to Noise Ratio and Medical Imaging.
spacer

• View the DATABASE results for 'Contrast to Noise Ratio' (2).Open this link in a new window


• View the NEWS results for 'Contrast to Noise Ratio' (1).Open this link in a new window.
 
Further Reading:
  Basics:
Vascular Filters of Functional MRI: Spatial Localization Using BOLD and CBV Contrast
Contrast mechanisms in magnetic resonance imaging
2004   by www.iop.org    
Optimal k-Space Sampling for Dynamic Contrast-Enhanced MRI with an Application to MR Renography
Thursday, 5 November 2009   by www.ncbi.nlm.nih.gov    
Searchterm 'Resonance' was also found in the following services: 
spacer
News  (791)  Resources  (184)  Forum  (1)  
 
Correlation Time
 
The characteristic time between significant fluctuations in the local magnetic field experienced by a spin due to molecular motions. For values of the correlation time such that the magnetic field as a function of time has large Fourier components near the resonance frequency, the T1 relaxation time will be shortened.
spacer

• View the DATABASE results for 'Correlation Time' (2).Open this link in a new window

Searchterm 'Resonance' was also found in the following services: 
spacer
Radiology  (15) Open this link in a new windowUltrasound  (32) Open this link in a new window
DecouplingInfoSheet: - Artifacts - 
Case Studies, 
Reduction Index, 
etc.
 
1) The specific irradiation designed to remove the multiple structure in a particular resonance due to spin spin coupling with other nuclei;
2) The preventing of the interaction by mutual inductive coupling of two (or more) resonant RF coils, e.g. by detuning coils not in use at a particular point in time. Decoupling can take the form of active decoupling where an externally controlled switching circuit is used to detune the non-selected coils or passive decoupling where RF energy from the transmitter pulse is used to switch diodes to detune the appropriate coil.
spacer

• View the DATABASE results for 'Decoupling' (3).Open this link in a new window

 
Further Reading:
  Basics:
A Half-Volume Coil for Efficient Proton Decoupling in Humans at 4 Tesla
1997   by www.cmrr.umn.edu    
MRI Resources 
Services and Supplies - Crystallography - Nerve Stimulator - Spectroscopy - MRI Reimbursement - MRI Centers
 
previous      81 - 85 (of 169)     next
Result Pages : [1 2 3 4 5 6]  [7 8 9 10 11 12 13 14 15 16 17 18 19 20 ... ]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



New acceleration techniques will :
reduce scan times 
cause artifacts 
increase expenses 
be useful if you have a lot of experience 
doesn't do much 
never heard of 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 29 April 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]