Magnetic Resonance - Technology Information Portal Welcome to MRI Technology
Info
  Sheets

Out-
      side
 



 
 'Precess' 
SEARCH FOR    
 
  2 3 5 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Result : Searchterm 'Precess' found in 9 terms [] and 43 definitions []
previous     36 - 40 (of 52)     next
Result Pages : [1 2]  [3 4 5 6 7 8 9 10 11]
Searchterm 'Precess' was also found in the following services: 
spacer
News  (3)  Forum  (5)  
 
Fat SuppressionForum -
related threads
 
Fat suppression is the process of utilizing specific MRI parameters to remove the deleterious effects of fat from the resulting images , e.g. with STIR, FAT SAT sequences, water selective (PROSET WATS - water only selection, also FATS - fat only selection possible) excitation techniques, or pulse sequences based on the Dixon method.
Spin magnetization can be modulated by using special RF pulses. CHESS or its variations like SPIR, SPAIR (Spectral Selection Attenuated Inversion Recovery) and FAT SAT use frequency selective excitation pulses, which produce fat saturation.
Fat suppression techniques are nearly used in all body parts and belong to every standard MRI protocol of joints like knee, shoulder, hips, etc.
mri safety guidance
Image Guidance
Imaging of, e.g. the foot can induce bad fat suppression with SPIR/FAT SAT due to the asymmetric volume of this body part. The volume of the foot alters the magnetic field to a different degree than the smaller volume of the lower leg affecting the protons there. There is only a small band of tissue where the fat protons are precessing at the frequency expected, resulting in frequency selective fat saturation working only in that area. This can be corrected by volume shimming or creating a more symmetrical volume being imaged with water bags.
Even with their longer scan time and motion sensitivity, STIR (short T1/tau inversion recovery) sequences are often the better choice to suppress fat. STIR images are also preferred because of the decreased sensitivity to field inhomogeneities, permitting larger fields of views when compared to fat suppressed images and the ability to image away from the isocenter.
See also Knee MRI.
Sequences based on Dixon turbo spin echo (fast spin echo) can deliver a significant better fat suppression than conventional TSE/FSE imaging.
 
Images, Movies, Sliders:
 Shoulder Axial T2 FatSat FRFSE  Open this link in a new window
    

Courtesy of  Robert R. Edelman
 MRI Orbita T2 FatSat  Open this link in a new window
    
 Knee MRI Sagittal STIR 001  Open this link in a new window
 MRI - Anatomic Imaging of the Ankle 3  Open this link in a new window
    
SlidersSliders Overview

 
spacer
 
• Related Searches:
    • Fat Saturation
    • Shoulder MRI
    • Water Fat Shift
    • Spectral Presaturation Inversion Recovery
    • Short T1 Inversion Recovery
 
Further Reading:
  Basics:
Techniques of Fat Suppression(.pdf)
   by cds.ismrm.org    
  News & More:
Enhanced Fast GRadient Echo 3-Dimensional (efgre3D) or THRIVE
   by www.mri.tju.edu    
Ultrashort echo time (UTE) MRI of the spine in thalassaemia
February 2004   by bjr.birjournals.org    
MRI Resources 
Sequences - Shielding - Shoulder MRI - Jobs - Breast Implant - Jobs pool
 
Inversion Recovery Fast Gradient Recalled Acquisition in the Steady StateInfoSheet: - Sequences - 
Intro, 
Overview, 
Types of, 
etc.MRI Resource Directory:
 - Sequences -
 
spacer
MRI Resources 
Jobs pool - Databases - PACS - Artifacts - Service and Support - MRI Technician and Technologist Career
 
Isochromat
 
A microscopic group of spins, which resonate at the same frequency. The spin precesses around a circle in the xy-plane and the net magnetization is the length, amplitude or magnitude of the magnetization vector Mxy: the quantity normally represented on a pixel-by-pixel basis in a MR image (thus amplitude or magnitude image).
spacer

• View the DATABASE results for 'Isochromat' (4).Open this link in a new window

Searchterm 'Precess' was also found in the following services: 
spacer
News  (3)  Forum  (5)  
 
Larmor Equation
 
The Larmor equation is important because it is the frequency at which the nucleus will absorb energy. The absorption of that energy will cause the proton to alter its alignment and ranges from 1-100 MHz in MRI. The equation states that the frequency of precession of the nuclear magnetic moment is directly proportional to the product of the magnetic field strength (B0) and the gyromagnetic ratio (g). This is stated mathematically as w = g B0.
spacer

• View the DATABASE results for 'Larmor Equation' (6).Open this link in a new window

 
Further Reading:
  News & More:
Electron and proton gyromagnetic ratios
   by www.phys.au.dk    
MRI Resources 
Collections - Resources - Sequences - Mobile MRI - Homepages - RIS
 
MRIForum -
related threads
 
 
Images, Movies, Sliders:
 Sagittal Knee MRI Images STIR  Open this link in a new window
      

 Cardiac Infarct Short Axis Cine Overview  Open this link in a new window
 Breast MRI Images T2 And T1  Open this link in a new window
 TOF-MRA Circle of Willis Inverted MIP  Open this link in a new window
    

 
spacer

• View the DATABASE results for 'MRI' (561).Open this link in a new window


• View the NEWS results for 'MRI' (418).Open this link in a new window.
 
Further Reading:
  Basics:
A Short History of the Magnetic Resonance Imaging (MRI)
   by www.teslasociety.com    
  News & More:
MRI for Patients with Cardiac Device, Covered
Thursday, 3 October 2019   by www.aapc.com    
Bringing More Value to Imaging Departments With MRI
Friday, 4 October 2019   by www.itnonline.com    
The world's strongest MRI machines are pushing human imaging to new limits
Wednesday, 31 October 2018   by www.nature.com    
MRI Resources 
Distributors - General - Pathology - MRI Reimbursement - DICOM - Cardiovascular Imaging
 
previous      36 - 40 (of 52)     next
Result Pages : [1 2]  [3 4 5 6 7 8 9 10 11]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



MRI is trending to low field magnets :
reduced costs will lead to this change 
AI will close the gap to high field 
only in remote areas 
is only temporary 
never 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 5 May 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]