Magnetic Resonance - Technology Information Portal Welcome to MRI Technology
Info
  Sheets

Out-
      side
 



 
 'Intera' 
SEARCH FOR    
 
  2 3 5 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Result : Searchterm 'Intera' found in 9 terms [] and 36 definitions []
previous     41 - 45 (of 45)     
Result Pages : [1 2]  [3 4 5 6 7 8 9]
Searchterm 'Intera' was also found in the following services: 
spacer
News  (9)  Resources  (22)  Forum  (10)  
 
T2 RelaxationForum -
related threads
 
The dephasing of the protons is named the T2, spin-spin or transverse relaxation. The T2 time constant is the time taken for spinning protons to lose phase coherence among the nuclei spinning perpendicular to the main field. This interaction between spins results in a reduction in the transverse magnetization. The value of T2 depends on the mobility of the protons. A large mobility results in an average magnetic field variation of zero, resulting in a long T2 period of this tissue.

See also T2 Time.
 
Images, Movies, Sliders:
 Anatomic MRI of the Neck  Open this link in a new window
    
SlidersSliders Overview

 Brain MRI Transversal T2 002  Open this link in a new window
    
 
spacer
 
• Related Searches:
    • Superparamagnetic Iron Oxide
    • Bloch Equations
    • Blood Oxygenation Level Dependent Contrast
    • Magnetization Transfer
    • Contrast Agents
 
Further Reading:
  Basics:
Musculoskeletal MRI at 3.0 T: Relaxation Times and Image Contrast
Sunday, 1 August 2004   by www.ajronline.org    
IMAGE CONTRAST IN MRI(.pdf)
   by www.assaftal.com    
  News & More:
Periodical assessment of four horns of knee meniscus using MR T2 mapping imaging in volunteers before and after amateur marathons
Friday, 15 July 2022   by www.nature.com    
MRI T2 Mapping of the Knee Providing Synthetic Morphologic Images: Comparison to Conventional Turbo Spin-Echo MRI
Tuesday, 1 October 2019   by pubs.rsna.org    
Iron Measurements with MRI Reveal Stroke's Impact on Brain
Tuesday, 12 March 2019   by www.rsna.or    
MRI Resources 
Sequences - Process Analysis - Pacemaker - Coils - Functional MRI - Devices
 
T2 TimeForum -
related threads
 
The T2 relaxation time (spin spin relaxation time or transverse relaxation time), is a biological parameter that is used in MRIs to distinguish between tissue types and is termed 'Time 2' or T2. It is a tissue-specific time constant for protons and is dependent on the exchanging of energy with near by nuclei. T2 weighted images rely upon local dephasing of spins following the application of the transverse energy pulse. T2 is the decay of magnetization perpendicular to the main magnetic field (in an ideal homogeneous field).
Due to interaction between the spins, they lose their phase coherence, which results in a loss of transverse magnetization and MRI signal. After time T2 transverse magnetization has lost 63% of its original value. This tissue parameter determines the contrast.
The T2 relaxation is temperature dependent. At a lower temperature molecular motion is reduced and the decay times are reduced.
Fat has a very efficient energy exchange and therefore it has a relatively short T2.
Water is less efficient than fat in the exchange of energy, and therefore it has a long T2 time.

See also T2 Weighted Image and Magnetic Resonance Imaging MRI.
 
Images, Movies, Sliders:
 Breast MRI Images T2 And T1  Open this link in a new window
      
 MRI of the Skull Base  Open this link in a new window
    
SlidersSliders Overview

 Knee MRI Transverse 002  Open this link in a new window
    
 
spacer

• View the DATABASE results for 'T2 Time' (16).Open this link in a new window

 
Further Reading:
  News & More:
MYELIN-SELECTIVE MRI: PULSE SEQUENCE DESIGN AND OPTIMIZATION
   by www.imaging.robarts.ca    
MRI Resources 
Directories - MRA - Sequences - Education - IR - Movies
 
T2*Forum -
related threads
 
T2* (also called T2 Star) is composed of molecular interactions (spin spin relaxation) and local magnetic field non-uniformities. Caused by this the protons precess at slightly different frequencies. The T2* effect cause a rapid loss in coherence and transverse magnetization. The T2* time is less than the T2 time.

See also T2* Time, T2 Star.
spacer

• View the DATABASE results for 'T2*' (42).Open this link in a new window

 
Further Reading:
  Basics:
IMAGE CONTRAST IN MRI(.pdf)
   by www.assaftal.com    
T2* cardiac MRI allows prediction of severe reperfusion injury after STEMI
Tuesday, 9 November 2010   by www.medwire-news.md    
Introduction to MRI Physics, Page 9
   by www.simplyphysics.com    
  News & More:
Scientists create imaging 'toolkit' to help identify new brain tumor drug targets
Tuesday, 2 February 2016   by www.eurekalert.org    
Resonance Health Limited (RHT.AX) Receives FDA Approval for MRI-Q Cardiac Iron T2* Test
Tuesday, 16 August 2011   by www.biospace.com    
MRI effectively measures hemochromatosis iron burden
Saturday, 3 October 2015   by medicalxpress.com    
Principles, Techniques, and Applications of T2*- based MR Imaging and Its Special Applications1
September 2009   by pubs.rsna.org    
Searchterm 'Intera' was also found in the following services: 
spacer
News  (9)  Resources  (22)  Forum  (10)  
 
Transverse Relaxation Time
 
The T2 time constant, which determines the rate at which excited protons reach equilibrium, or go out of phase with each other. A measure of the time taken for spinning protons to lose phase coherence among the nuclei spinning perpendicular to the main field due to interaction between spins, resulting in a reduction in the transverse magnetization. The transverse magnetization value will drop from maximum to a value of about 37% of its original value in a time of T2.
 
Images, Movies, Sliders:
 Brain MRI Images Axial T2  Open this link in a new window
      

 Breast MRI 2 Transverse T2 001  Open this link in a new window
 
spacer

• View the DATABASE results for 'Transverse Relaxation Time' (4).Open this link in a new window

MRI Resources 
Absorption and Emission - RIS - MRI Technician and Technologist Jobs - Breast MRI - Devices - Pacemaker
 
Volume ShimForum -
related threads
 
Shimming corrects local magnetic field inhomogeneities by adjusting the static gradients. A volume shim enables the shim volume to be limited. This local 3D shim provides a more precise result and therefore a better fat saturation. For spectroscopy, it provides a better starting value for an interactive shim.
spacer

• View the DATABASE results for 'Volume Shim' (2).Open this link in a new window

 
Further Reading:
  Basics:
Improved shim method based on the minimization of the maximum off-resonance frequency for balanced SSFP
Monday, 1 June 2009   by www.ncbi.nlm.nih.gov    
  News & More:
Implementation of Dual-Source RF Excitation in 3 T MR-Scanners Allows for Nearly Identical ADC Values Compared to 1.5 T MR Scanners in the Abdomen
Wednesday, 29 February 2012   by www.plosone.org    
MRI Resources 
Absorption and Emission - Implant and Prosthesis pool - Stimulator pool - Lung Imaging - Diffusion Weighted Imaging - Abdominal Imaging
 
previous      41 - 45 (of 45)     
Result Pages : [1 2]  [3 4 5 6 7 8 9]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



MRI is trending to low field magnets :
reduced costs will lead to this change 
AI will close the gap to high field 
only in remote areas 
is only temporary 
never 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 27 April 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]