Quality Factor
 
The quality factor (Q) applies to any resonant circuit component; most often the quality factor of the coil determines the overall Q of the circuit.
Inversely related to the fraction of the energy in an oscillating system lost in one oscillation cycle. Q is inversely related to the range of frequency over which the system will exhibit resonance.
In a parallel tuned circuit (such as used in a MR coil), the quality factor is defined as:
Q = vL/R
where L is the coil inductance, R is the circuit resistance, and v is the angular frequency. Increasing quality factor results in improving the signal to noise ratio SNR by a factor √Q and also produces a sharper frequency response (decreased band width). The Q of a coil will depend on the circumstances under which it is measured, e.g. whether it is 'unloaded' (no patient) or 'loaded' (patient).
spacer
 
• Related Searches:
    • Resonance
    • Circularly Polarized Coil
    • Transmitter Coil
    • Image Quality
    • Coil Loading
Searchterm 'Frequency' was also found in the following services: 
spacer
Radiology  (24) Open this link in a new windowUltrasound  (158) Open this link in a new window
Spatial Misregistration ArtifactInfoSheet: - Artifacts - 
Case Studies, 
Reduction Index, 
etc.MRI Resource Directory:
 - Artifacts -
 
An effect of chemical shift is that of spatial misregistration. Because the frequency displacement caused by chemical shift cannot be differentiated from intended spatial frequency encoding misregistration of the resultant signal may occur along the frequency-encoding direction. This artifact can be seen in a FFE or SE sequence as a bright or dark band at the edge of the anatomy.

See Chemical Shift Artifact.
spacer
MRI Resources 
Guidance - Quality Advice - MRI Physics - Cochlear Implant - Functional MRI - Patient Information
 
Specific Absorption Rate
 
(SAR) The Specific Absorption Rate is defined as the RF power absorbed per unit of mass of an object, and is measured in watts per kilogram (W/kg).
The SAR describes the potential for heating of the patient's tissue due to the application of the RF energy necessary to produce the MR signal. Inhomogeneity of the RF field leads to a local exposure where most of the absorbed energy is applied to one body region rather than the entire person, leading to the concept of a local SAR. Hot spots may occur in the exposed tissue, to avoid or at least minimize effects of such theoretical complications, the frequency and the power of the radio frequency irradiation should be kept at the lowest possible level. Averaging over the whole body leads to the global SAR.
It increases with field strength, radio frequency power and duty cycle, transmitter-coil type and body size. The doubling of the field strength from 1.5 Tesla (1.5T) to 3 Tesla (3T) leads to a quadrupling of SAR. In high and ultrahigh fields, some of the multiple echo, multiple-slice pulse sequences may create a higher SAR than recommended by the agencies. SAR can be reduced by lower flip angle and longer repetition times, which could potentially affect image contrast.
Normally no threatening increase in temperature could be shown. Even in high magnetic fields, the local temperature increases not more than 1°C. 2.1°C is the highest measured increase in skin temperature. Eddy currents may heat up implants and thus may cause local heating.

FDA SAR limits:
•
Whole body: 4W/kg/15-minute exposure averaged;
•
Head: 3W/kg/10-minute exposure averaged;
•
Head or torso: 8W/kg/5 minute exposure per gram of tissue;
•
Extremities: 12W/kg/5 minute exposure per gram of tissue.

IEC (International Electrotechnical Commission) SAR limits of some European countries:
All limits are averaged over 6 minutes.
•
Level 0 (normal operating mode): Whole body 2W/kg; Head 3.2W/kg; Head or Torso (local) 10W/kg; Extremities (local) 20W/kg;
•
Level I (first level controlled operating mode): Whole body 4W/kg; Head 3.2W/kg; Head or Torso (local) 10W/kg; Extremities (local) 20W/kg;
•
Level II (second level controlled operating mode): All values are over Level I values.
(For more details: IEC 60601-2-33 (2002))

In most countries standard MRI systems are limited to a maximum SAR of 4 W/kg, so most scanning in level II is impossible.
For Level I, in addition to routine monitoring, particular caution must be exercised for patients who are sensitive to temperature increases or to RF energy.
For Japan different SAR limits are valid.
spacer

• View the DATABASE results for 'Specific Absorption Rate' (8).Open this link in a new window


• View the NEWS results for 'Specific Absorption Rate' (1).Open this link in a new window.
 
Further Reading:
  Basics:
SED Guidance
Saturday, 1 January 2022   by www.mriphysics.scot.nhs.uk    
On the estimation of the worst-case implant-induced RF-heating in multi-channel MRI.
Thursday, 2 March 2017   by www.ncbi.nlm.nih.gov    
What MRI Sequences Produce the Highest Specific Absorption Rate (SAR), and Is There Something We Should Be Doing to Reduce the SAR During Standard Examinations?
Thursday, 16 April 2015   by www.ajronline.org    
Evaluation of Specific Absorption Rate as a Dosimeter of MRI-Related Implant Heating
2004   by www.imrser.org    
  News & More:
Specific Absorption Rate and Specific Energy Dose: Comparison of 1.5-T versus 3.0-T Fetal MRI
Tuesday, 7 April 2020   by pubs.rsna.org    
MRI in Patients with Implanted Devices: Current Controversies
Monday, 1 August 2016   by www.acc.org    
Commission delays electromagnetic fields legislation
Monday, 29 October 2007   by cordis.europa.eu:80    
Accounting for biological aggregation in heating and imaging of magnetic nanoparticles
Tuesday, 2 September 2014   by www.ecnmag.com    
Guidance for Industry and FDA Staff, Criteria for Significant Risk Investigations of Magnetic Resonance Diagnostic Devices
Monday, 14 July 2003   by www.fda.gov    
Searchterm 'Frequency' was also found in the following services: 
spacer
News  (11)  Resources  (6)  Forum  (11)  
 
Acquisition Matrix
 
The total number of independent data samples in the frequency and phase directions (number of pixels in the frequency encoding - and phase encoding direction).
spacer

• View the DATABASE results for 'Acquisition Matrix' (12).Open this link in a new window

Searchterm 'Frequency' was also found in the following services: 
spacer
Radiology  (24) Open this link in a new windowUltrasound  (158) Open this link in a new window
Adiabatic Fast Passage
 
(AFP) Adiabatic fast passage is a NMR technique of producing rotation of the macroscopic magnetization vector by shifting the frequency of RF energy pulses (or the strength of the magnetic field) through resonance (the Larmor frequency) in a time short compared to the relaxation times. Particularly used for inversion of the spins between high and low energy states with an excess of spins in the higher energy level. A continuous wave NMR technique used in e.g., MR spectroscopy.
spacer

• View the DATABASE results for 'Adiabatic Fast Passage' (3).Open this link in a new window

 
Further Reading:
  Basics:
Adiabatic theorem
   by en.wikipedia.org    
  News & More:
New theory of adiabaticity developed
Tuesday, 2 December 2008   by www.upi.com    
MRI Resources 
Databases - Claustrophobia - MRI Technician and Technologist Career - Used and Refurbished MRI Equipment - MRI Accidents - Open Directory Project
 
previous      51 - 55 (of 218)     next
Result Pages : [1 2 3 4 5]  [6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 ... ]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



New acceleration techniques will :
reduce scan times 
cause artifacts 
increase expenses 
be useful if you have a lot of experience 
doesn't do much 
never heard of 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 3 May 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]