From GE Healthcare;
The Signa SP 0.5T™ is an open MRI magnet that is designed for use in interventional radiology and intra-operative imaging. The vertical gap configuration increases patient positioning options, improves patient observation, and allows continuous access to the patient during imaging.
The magnet enclosure also incorporates an intercom, patient observation video camera, laser patient alignment lights, and task lighting in the imaging volume.
Device Information and Specification CLINICAL APPLICATION Whole body Integrated transmit and receive body coil; optional rotational body coil, head; other coils optional; open architecture makes system compatible with a wide selection of coilsarray Standard: SE, IR, 2D/3D GRE and SPGR, 2D/3D TOF, 2D/3D FSE, 2D/3D FGRE and FSPGR, SSFP, FLAIR, EPI, optional: 2D/3D Fiesta, true chem sat, fat/water separation, single shot diffusion EPI IMAGING MODES Localizer, single slice, multislice, volume, fast, POMP, multi slab, cine, slice and frequency zip, extended dynamic range, tailored RF TR 1.3 to 12000 msec in increments of 1 msec TE 0.4 to 2000 msec in increments of 1 msec 2D: 1.4mm - 20mm 3D: 0.2mm - 20mm POWER REQUIREMENTS 200 - 480, 3-phase | | | | | Further Reading: | News & More:
|
|
| |
| | | | | |
| |
|
| | | | • View the DATABASE results for 'Signal Averaging' (6).
| | | | |
| | | | | |
| |
|
( SPIR) A specialized technique that selectively saturates fat protons prior to acquiring data as in standard sequences, so that they produce a negligible signal. The presaturation pulse is applied prior to each slice selection. This technique requires a very homogeneous magnetic field and very precise frequency calibration. | | | | | | • View the DATABASE results for 'Spectral Presaturation Inversion Recovery' (2).
| | | | Further Reading: | Basics:
|
|
| |
| | | Searchterm 'SPIR' was also found in the following services: | | | | |
| | |
| |
|
Controlling the timing or sequence of image data acquisition according to the phase of re spiratory or cardiac cycles. | | | | | |
| | | | | |
| |
|
Sorting and possibly adjusting image data acquired asynchronously with the cardiac or re spiratory cycle, according to the phase of the cycle at which it was acquired, so as to reconstruct a set of images corresponding to different phases of the cycle. | | | | | | | |
| | | | |
| |
| | | |
|
| |