Magnetic Resonance - Technology Information Portal Welcome to MRI Technology
Info
  Sheets

Out-
      side
 



 
 'Enhancement' 
SEARCH FOR    
 
  2 3 5 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Result : Searchterm 'Enhancement' found in 3 terms [] and 73 definitions []
previous     56 - 60 (of 76)     next
Result Pages : [1]  [2 3 4 5 6 7 8 9 10 11 12 13 14 15 16]
Searchterm 'Enhancement' was also found in the following services: 
spacer
News  (15)  Forum  (6)  
 
Magnevist® EnteralInfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
Magnevist® enteral (Gadopentetate) is a Gd-DTPA solution for use as a gastrointestinal contrast agent to visualize the bowel in MRI scans.

See also Positive Oral Contrast Agents and Gadopentetate Gastrointestinal.
Drug Information and Specification
CENTRAL MOIETY
Gd3+
CONTRAST EFFECT
T1, Predominantly positive enhancement
Paramagnetic
PHARMACOKINETIC
Gastrointestinal
CONCENTRATION
0.001 mol/L
DOSAGE
100 ml oral
PREPARATION
Finished product
INDICATION
Bowel marking
DEVELOPMENT STAGE
For sale
DISTRIBUTOR
See below
PRESENTATION
Vial of 100 mL
DO NOT RELY ON THE INFORMATION PROVIDED HERE, THEY ARE
NOT A SUBSTITUTE FOR THE ACCOMPANYING PACKAGE INSERT!
Distribution Information
TERRITORY
TRADE NAME
DEVELOPMENT
STAGE
DISTRIBUTOR
USA
Magnevist® enteral
for sale
EU
Magnevist® enteral
for sale
spacer
MRI Resources 
Developers - Distributors - Crystallography - Artifacts - Chemistry - Spectroscopy
 
Mangafodipir TrisodiumInfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
Short name: Mn-DPDP
This MRI contrast agent is a chelate complex of the paramagnetic metal ion manganese (Mn) and fodipir. Mn-DPDP (Teslascan) shortens the longitudinal relaxation time and is used for the T1 weighted enhancement of MR images. Mangafodipir trisodium accumulates after intravenous injection in the healthy tissue of the liver and improves the detection, localization, characterization, and evaluation of lesions of the liver, pancreas, but can also be used in cardiac MRI.
See also Hepatobiliary Chelates and Teslascan®.
The United States Food and Drug Administration (FDA) has granted marketing clearance 1997, to Nycomed Amersham's MRI contrast medium. Nycomed/Amersham, now GE Healthcare markets the product under the trade name Teslascan®.
spacer

• View the DATABASE results for 'Mangafodipir Trisodium' (6).Open this link in a new window


• View the NEWS results for 'Mangafodipir Trisodium' (1).Open this link in a new window.
 
Further Reading:
  Basics:
Teslascan Pharmacology, Pharmacokinetics, Studies, Metabolism - Mangafodipir - RxList Monograph
   by www.rxlist.com    
Mangafodipir (Systemic)
2003   by www.drugs.com    
  News & More:
Diagnosis and staging of pancreatic cancer: comparison of mangafodipir trisodium-enhanced MR imaging and contrast-enhanced helical hydro-CT.
2002
MRI Resources 
Veterinary MRI - Collections - Health - MR Myelography - Breast MRI - Pacemaker
 
MetalloporphyrinsInfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.
 
Porphyrins occur naturally in plants and animals. All porphyrin molecules feature an aromatic macrocycle ring with a central binding site. This site accommodates transition metals, which are held in place by inward-facing nitrogen atoms. Metalloporphyrins have usually a low toxicity and a potential of a selective uptake in tumors or necrosis. These properties are advantageous for a use as MRI tumor specific agents with positive enhancement. These contrast agents enhance tumors on T1 weighted sequences, which are isointense to surrounding tissues. Porphyrin-based compounds have also necrosis avid properties; they can depict the extent of myocardial infarction as defined by histopathology.
Metalloporphyrins are also used in photodynamic therapy of tumors. The compounds contain a 'lone star' metal atom at the center of the ring and are 'bigger than the average porphyrin'. They contain five N atoms in the central chelating core and this allows them to form complexes with large trivalent lanthanide metals, which have useful cancer therapy properties.

See also Classifications, Characteristics, etc., Gadophrin, MnIIITPPS4, Necrosis Avid Contrast Agent.
spacer

• View the DATABASE results for 'Metalloporphyrins' (6).Open this link in a new window

 
Further Reading:
  Basics:
Relaxometric Investigation of Functional Group Placement on MnTPP Derivatives Supports the Role of the Molecular Electrostatic Potential Maps as a Tool to Design New Metalloporphyrins with Larger Relaxivities(.pdf)
   by www.mdpi.org    
Noninvasive Measurements of Infarct Size After Thrombolysis With a Necrosis-Avid MRI Contrast Agent
1999   by circ.ahajournals.org    
Searchterm 'Enhancement' was also found in the following services: 
spacer
News  (15)  Forum  (6)  
 
Motion Probing Gradient
 
Many MR imaging techniques using Motion Probing Gradients (MPG's) such as Spin Echo (SE), Stimulated Echo (STE), Rapid Acquisition with Relaxation Enhancement (RARE), Turbo-SE, and SE-EPI (Echo Planar Imaging for Spin echo acquisition), Spiral imaging, and Projection reconstruction including PROPELLER are applicable to DWI. In diffusion weighted imaging, 2 MPG's are required. The MPG's are put symmetrically into both sides of a 180° or 90° RF pulse to change the direction of the magnetized spin in the X-Y plane for spin echo or stimulated echo acquisition.
spacer

• View the DATABASE results for 'Motion Probing Gradient' (2).Open this link in a new window

 
Further Reading:
  Basics:
Diffusion Imaging: From Basic Physics to Practical Imaging
1999   by ej.rsna.org    
  News & More:
Motion Compensation in MR Imaging
   by ccn.ucla.edu    
MRI Resources 
Safety Products - MRI Centers - Crystallography - Movies - Used and Refurbished MRI Equipment - Supplies
 
MultiHance®InfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
MultiHance® is a paramagnetic contrast agent for use in diagnostic magnetic resonance imaging (MRI) of the liver and central nervous system. MultiHance® is a small molecular weight chelate, which tightly binds the Gd atom. The substance is excreted partly by the kidneys, partly by the biliary system, which is especially unique.
MultiHance® is indicated, for the detection of focal liver lesions in patients with known or suspected primary liver cancer (e.g. hepatocellular carcinoma) or metastatic disease.
MultiHance® is also indicated in brain MRI and spine MRI where it improves the detection of lesions and provides diagnostic information additional to that obtained with unenhanced MRI.
Gd-BOPTA-enhanced MRA can provide superior vascular signal intensity and SNR, as compared with Gd-DTPA, due to its higher relaxivity, even at lower doses.
1 ml of solution MultiHance® contains: (0.5M) gadobenate dimeglumine 529 mg = gadobenic acid 334 mg + meglumine 195 mg. Viscosity at 37°C: 5.3 mPa

WARNING: NEPHROGENIC SYSTEMIC FIBROSIS Gadolinium-based contrast agents increase the risk for nephrogenic systemic fibrosis (NSF) in patients with acute or chronic severe renal insufficiency (glomerular filtration rate less than 30 mL/min/1.73m2), or acute renal insufficiency of any severity due to the hepato-renal syndrome or in the perioperative liver transplantation period.
Drug Information and Specification
NAME OF COMPOUND
Gadobenate dimeglumine, Gd-BOPTA, E7155
DEVELOPER
CENTRAL MOIETY
Gd2+
CONTRAST EFFECT
T1, predominantly positive enhancement
r1=9.7, r2=12.5, B0=0.5 T
PHARMACOKINETIC
Extracellular, hepatobiliary
1970 mosm/kg
CONCENTRATION
334 mg/ml
DOSAGE
0.05 mmol/kg for Liver MRI
0.1 mmol/kg for CNS MRI
PREPARATION
Solution for injection
INDICATION
CNS, Liver MRI
DEVELOPMENT STAGE
For sale
DISTRIBUTOR
See below
PRESENTATION
Vials of 5, 10, 15 and 20 mL, 50 and 100 mL Multipacks (Pharmacy Bulk Package)
DO NOT RELY ON THE INFORMATION PROVIDED HERE, THEY ARE
NOT A SUBSTITUTE FOR THE ACCOMPANYING PACKAGE INSERT!
Distribution Information
TERRITORY
TRADE NAME
DEVELOPMENT
STAGE
DISTRIBUTOR
EU
MultiHance®
for sale
USA
MultiHance®
for sale
Australia
MultiHance®
for sale
spacer

• View the DATABASE results for 'MultiHance®' (9).Open this link in a new window


• View the NEWS results for 'MultiHance®' (1).Open this link in a new window.
 
Further Reading:
  Basics:
Important Drug Warning for Gadolinium-Based Contrast Agents
Wednesday, 12 September 2007   by www.ismrm.org    
MultiHance Package Insert(.pdf)
   by www.fda.gov    
  News & More:
FDA Expands Pediatric Age Range for MultiHance Contrast Agent
Tuesday, 30 January 2018   by www.empr.com    
MAGNETIC RESONANCE IMAGING OF FOCAL LIVER LESIONS(.pdf)
2002
BRACCO DIAGNOSTICS' MULTIHANCE EARNS FDA APPROVAL
Wednesday, 24 November 2004   by salesandmarketingnetwork.com    
MRI Resources 
Libraries - Societies - MRI Accidents - Directories - Jobs pool - Knee MRI
 
previous      56 - 60 (of 76)     next
Result Pages : [1]  [2 3 4 5 6 7 8 9 10 11 12 13 14 15 16]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



MRI is trending to low field magnets :
reduced costs will lead to this change 
AI will close the gap to high field 
only in remote areas 
is only temporary 
never 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 2 May 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]