Magnetic Resonance - Technology Information Portal Welcome to MRI Technology
Info
  Sheets


Out-
      side
 



 
 'Device Information' 
SEARCH FOR    
 
  2 3 5 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Result : Searchterm 'Device Information' found in 0 term [] and 70 definitions []
previous     26 - 30 (of 70)     next
Result Pages : [1 2 3 4 5 6 7 8 9 10 11 12 13 14]
Searchterm 'Device Information' was also found in the following services: 
spacer
News  (2)  Resources  (4)  
 
MAGNETOM Avanto™InfoSheet: - Devices -
Intro, 
Types of Magnets, 
Overview, 
etc.MRI Resource Directory:
 - Devices -
 
From Siemens Medical Systems;
test.med.siemens.com/magnetom/rsna_chicago_2003/tim/avanto/index.php MAGNETOM Avanto with Tim – Total imaging matrix technology. For true whole-body anatomical coverage. For ultra-fast image acquisition. Aids the physician in fast and precise evaluation of systemic diseases like colon cancer, metastasis imaging, vessel diseases, and preventional exams. For claustrophobic patients, MAGNETOM Avanto enables feetfirst exams for nearly all MR procedures. For obese patients, MAGNETOM Avanto supports up to 200 kg (400 lbs), without table movement restrictions. The AudioComfort technology enables up to a 30 dB(A) acoustic noise reduction, that means nearly all clinical routine sequences are running under 99 dB(A).

Device Information and Specification
CLINICAL APPLICATION Whole body
CONFIGURATION Compact short bore
SURFACE COILS Body, Tim [32 x 8], Tim [76 x18], Tim [76 coil elements with up to 32 RF channels]
SPECTROSCOPY Yes/SVS or CSI opt.
SYNCHRONIZATION ECG/peripheral, respiratory gating
PULSE SEQUENCES GRE, IR, FIR, STIR, TrueIR/FISP, FSE, FLAIR, MT, SS-FSE, MT-SE, MTC, MSE, EPI, 3D DESS//CISS/PSIF, GMR
IMAGING MODES Single, multislice, volume study, multi angle, multi oblique
FOV 0.5 cm - 50 cm
SLICE THICKNESS Min 2D/3D: 0.1/0.05 mm
DISPLAY MATRIX 1024 x 1024 full screen display
MEASURING MATRIX 64 x 64 to 1024 x 1024
SPATIAL RESOLUTION 10 micrometer in plane
MAGNET TYPE Superconducting
BORE DIAMETER
or W x H
60 cm
POWER REQUIREMENTS 380/400/420/440/480 V
FIELD STRENGTH 1.5 T
STRENGTH up to 45 mT/m
5-GAUSS FRINGE FIELD 2.5 m / 4.0 m
SHIMMING Passive, act.; 1st order std./2nd opt.
spacer
 
• Related Searches:
    • MRI Equipment
    • Device
    • Hardware
    • High Field MRI
    • Low Field MRI
 
Further Reading:
  Basics:
12 510(k) MAGNETOM Avanto System(.pdf)
   by www.accessdata.fda.gov    
  News & More:
Obesity May Influence Imaging Diagnosis
Wednesday, 22 December 2004   by www.hospimedica.com    
MRI Resources 
Safety Training - Education pool - Process Analysis - Non-English - Distributors - Jobs
 
MAGNETOM Concerto™InfoSheet: - Devices -
Intro, 
Types of Magnets, 
Overview, 
etc.MRI Resource Directory:
 - Devices -
 
From Siemens Medical Systems;
www.med.siemens.com/med/d/gg/mr/products/concerto.htm the MAGNETOM Concerto is easy to site and has low life cycle costs due to the permanent magnet. The powerful gradient system with 20 mT/m and a slew rate of 40 T/m/s permits high field applications on a low field open MRI system. The three-sided fully open magnet results in maximum acceptance of claustrophobic or anxious patients and patient access.
Device Information and Specification
CLINICAL APPLICATION Whole body
CONFIGURATION Open MRI
SURFACE COILS Body coil, head brain, spine, knee, neck, TMJ, extremity, shoulder, others
SPECTROSCOPY No
PULSE SEQUENCES GRE, IR, FIR, STIR, TrueIR/FISP, FSE, MT, SS-FSE, MT-SE, MTC, MSE, GMR, fat/water sat./exc.
IMAGING MODES Single, multislice, volume study, multi angle
SLICE THICKNESS Min 2D/3D: 0.1/0.05 mm
DISPLAY MATRIX 512 x 512 full screen display
MEASURING MATRIX 64 x 64 to 512 x 512
SPATIAL RESOLUTION 22 micrometer
MAGNET TYPE Permanent
MAGNET WEIGHT 11 000 kg
POWER REQUIREMENTS 380/400/420/440/480 V
FIELD STRENGTH 0.2 T
STRENGTH 20 mT/m
SHIMMING Passive, active
spacer

• View the DATABASE results for 'MAGNETOM Concerto™' (2).Open this link in a new window

MRI Resources 
MRI Technician and Technologist Jobs - Case Studies - Claustrophobia - Spine MRI - Safety Products - Breast MRI
 
MAGNETOM C™InfoSheet: - Devices -
Intro, 
Types of Magnets, 
Overview, 
etc.MRI Resource Directory:
 - Devices -
 
From Siemens Medical Systems;
www.medical.siemens.com A new, powerful, compact player in MRI. For both, patients and health care professionals, the mid-field has realized a giant step to cost efficient quality care. Obese patients and people with claustrophobia appreciate the comfortable side loading. The smallest pole diameter – 137 cm (54 inches) allows for optimal patient comfort.

Device Information and Specification
CLINICAL APPLICATION Whole body
CONFIGURATION C-shaped open MRI
SURFACE COILS Multi channel imaging, CP Head//Neck Array Coil, Body/Spine Array Coil, large, Transmit Coil
SYNCHRONIZATION ECG/peripheral: Optional/yes, respiratory gating
PULSE SEQUENCES SE, FLASH, FISP, IR, FIR, STIR, TrueIR/FISP, FSE, MT, SS-FSE, MT-SE, MTC, MSE, EPI, PSIF,
IMAGING MODES Single, multislice, volume study, multi angle, multi oblique
TR Min. TR 2.81 ms
TE Min. TE 0.98 ms
DISPLAY MATRIX 512 x 512 full screen display
MEASURING MATRIX 64 x 64 to 512 x 512
FOV 0.5 - 40 cm
MAGNET TYPE Permanent
BORE DIAMETER
or W x H
41 cm vertical gap distance
MAGNET WEIGHT 16000 kg
H*W*D 233 x 206 x 160 cm
FIELD STRENGTH 0.35 T
STRENGTH 24 mT/m
5-GAUSS FRINGE FIELD 2.2 m / 2.2 m
SHIMMING Passive and active
spacer

• View the DATABASE results for 'MAGNETOM C™' (2).Open this link in a new window

 
Further Reading:
  Basics:
Section 2: 510(k) Summary, MAGNETOM C! System Classification Name: Magnetic Resonance Diagnostic(.pdf)
   by www.accessdata.fda.gov    
Searchterm 'Device Information' was also found in the following services: 
spacer
News  (2)  Resources  (4)  
 
MAGNETOM ESSENZA
 
From Siemens Medical Systems;
www.healthcare.siemens.com/magnetic-resonance-imaging/0-35-to-1-5t-mri-scanner/magnetom-essenza/ Received FDA clearance in 2007.
The MAGNETOM Essenza is designed to combine high system performance with simple installation and power requirements to provide optimal operating costs for limited budgets. The standard system has up to 25 integrated coil elements and 8 independent radio frequency channels. Tim allows the combination of up to 4 different coils that reduce patient and coil repositioning.
The 1.5 Tesla system is designated for a complete range of clinical applications, including neurology, orthopedics, body imaging, angiography, cardiology, breast imaging, oncology and pediatric MRI.


Device Information and Specification
CLINICAL APPLICATION Whole Body
CONFIGURATION Ultra-short bore
FIELD STRENGTH 1.5 Tesla
SURFACE COILS Head, spine, torso/ body coil, neurovascular, cardiac, neck, and multi-purpose flex coils. Peripheral vascular, breast, shoulder, knee, wrist, foot//ankle, TMJ optional.
CHANNELS (min. / max. configuration) 8, 16
SPECTROSCOPY Chemical shift imaging and single volume spectroscopy
IMAGING TECHNIQUES iPAT, mSENSE and GRAPPA (image, k-space), noncontrast angiography, radial motion compensation
MINIMUM TR 3-D GRE: 1.58 (256 matrix)
MINIMUM TE 3-D GRE: 0.5 (256 matrix)
FOV 0.5 - 45 cm
BORE DIAMETER
At isocenter: 60 cm
TABLE CAPACITY 200 kg
MAGNET WEIGHT (gantry included) 4350 kg in operation
DIMENSION H*W*D (gantry included) 145 x 226 x 216 cm
5-GAUSS FRINGE FIELD 2.5 m / 4.0 m
MAGNET TYPE Superconducting
CRYOGEN USE Zero boil off rate, approx. 10 years
COOLING SYSTEM Water; single cryogen, 2 stage refrigeration
SLEW RATE up to 100 T/m/s
MAX. AMPLITUDE, RISE TIME 30 mT/m, 300 msec to 10 mT/m
SHIMMING Passive, active; first order standard second order optional
POWER REQUIREMENTS 380 / 400 / 420 / 440 / 460 / 480 V, 3-phase + ground; 45 kVA
spacer
 
Further Reading:
  Basics:
Magnetom Essenza - Typical Room Plan
   by ftp.siemensmedical.com    
MRI Resources 
Devices - Manufacturers - Homepages - Spectroscopy - Stent - Shoulder MRI
 
MAGNETOM Espree™InfoSheet: - Devices -
Intro, 
Types of Magnets, 
Overview, 
etc.MRI Resource Directory:
 - Devices -
 
www.medical.siemens.com From Siemens Medical Systems;
70 cm + 125 cm + 1.5T and Tim – a combination never seen before in MRI ... MAGNETOM Espree™’s unique open bore design can accommodate more types of patients than other 1.5T systems on the market today, in particular the growing population of obese patients. The power of 1.5T combined with Tim technology boosts signal to noise, which is necessary to adequately image obese patients.

Device Information and Specification
CLINICAL APPLICATION Whole body
CONFIGURATION Open bore
SURFACE COILS Body, Tim [32 x 8], Tim [76 coil elements with up to 18 RF channels])
SYNCHRONIZATION ECG/peripheral: Optional/yes, respiratory gating
PULSE SEQUENCES GRE, IR, FIR, STIR, TrueIR/FISP, FSE, FLAIR, MT, SS-FSE, MT-SE, MTC, MSE, EPI, 3D DESS//CISS/PSIF, GMR
IMAGING MODES Single, multislice, volume study, multi angle, multi oblique
SINGLE/MULTI SLICE Image Processor reconstructing up to 3226 images per second (256 x 256, 25% recFoV)
FOV 35 cm coronal//sagittal, 45 cm axial
SLICE THICKNESS Min 2D/3D: 0.1/0.05 mm
DISPLAY MATRIX 1024 x 1024 full screen display
MEASURING MATRIX 64 x 64 to 1024 x 1024
MAGNET TYPE Superconducting
BORE DIAMETER
or W x H
70 cm diameter
MAGNET WEIGHT 3800 kg
H*W*D ? x ? x 125 cm
FIELD STRENGTH 1.5 T
STRENGTH 33 mT/m
5-GAUSS FRINGE FIELD 2.5 m / 3.8 m
SHIMMING Passive and active
spacer

• View the DATABASE results for 'MAGNETOM Espree™' (2).Open this link in a new window

 
Further Reading:
  News & More:
First 1.5 Tesla Open Bore MRI Introduced
Tuesday, 10 August 2004   by www.hospimedica.com    
Obesity May Influence Imaging Diagnosis
Wednesday, 22 December 2004   by www.hospimedica.com    
MRI Resources 
Nerve Stimulator - Mobile MRI - Research Labs - Knee MRI - Jobs pool - Abdominal Imaging
 
previous      26 - 30 (of 70)     next
Result Pages : [1 2 3 4 5 6 7 8 9 10 11 12 13 14]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?  



In 2075 (after about 100 years of ...) the MRI scan will be :
obsolete 
done with handheld probe 
done at home (app, ...) 
a 3 second walk through 
daily done 
replaced by something much ... 

Look
      Ups





Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • US-TIP • The-Medical-Market
Copyright © 2003 - 2016 SoftWays. All rights reserved. [ 21 January 2017]
Terms of Use | Privacy Policy | Advertising
 [last update: 2017-01-13 03:47:00]