Magnetic Resonance - Technology Information Portal Welcome to MRI Technology
Info
  Sheets

Out-
      side
 



 
 'MR System' 
SEARCH FOR    
 
  2 3 5 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Result : Searchterm 'MR System' found in 0 term [] and 24 definitions []
previous     16 - 20 (of 24)     next
Result Pages : [1 2 3 4 5]
Searchterm 'MR System' was also found in the following services: 
spacer
News  (345)  Resources  (74)  Forum  (2)  
 
ONI Medical Systems, Inc.MRI Resource Directory:
 - Manufacturers -
 
www.onicorp.com Founded in June 1997, ONI was a privately held company headquartered in Wilmington, Massachusetts. ONI was focused on addressing the new healthcare economics by delivering the next generation of MRI machines: high field, low cost dedicated purpose systems. The company's first offering was the OrthOne™. Further developments lead to the MSK Extreme™, a 1.0 Tesla dedicated purpose MR system with v-SPEC™ Technology and DICOM Conformance for extremity applications.
In October 2009 GE Healthcare bought ONI Medical Systems for US$ 17 Billion.

MRI Scanners:

1.0T:
spacer

• View the NEWS results for 'ONI Medical Systems, Inc.' (4).Open this link in a new window.
MRI Resources 
Jobs pool - Mobile MRI Rental - Liver Imaging - Brain MRI - Portals - Contrast Agents
 
OPART™InfoSheet: - Devices -
Intro, 
Types of Magnets, 
Overview, 
etc.MRI Resource Directory:
 - Devices -
 
www3.toshiba.co.jp/medical/products/mr/opart/index.htm From Toshiba America Medical Systems Inc.;
OPART™ is a 0.35 T superconducting open MR system featuring cryogenless operation. Superconducting speed and performance are combined with the patient access advantages of open MRI design for unmatched clinical versatility. OPART™ features innovative technologies such as digital RF, high speed gradients and optimized RF coils, which support advanced MRI applications.
Device Information and Specification
CLINICAL APPLICATION
Whole body
CONFIGURATION
Quadrature, solenoid and multi-channel configurations
SYNCHRONIZATION
ECG/peripheral optional, respiratory gating
PULSE SEQUENCES
SE, FE, IR, FastSE, FastIR, FastFLAIR, Fast STIR, FastFE, FASE, Hybrid EPI, Multi Shot EPI; Angiography: 2D(gate/non-gate)/3D TOF, SORS-STC
IMAGING MODES
Single, multislice, volume study
55 cm, vertical opening
POWER REQUIREMENTS
380/400/415/440/480 V
COOLING SYSTEM TYPE
Cryogenless
STRENGTH
25 mT/m
Passive, active
spacer

• View the DATABASE results for 'OPART™' (2).Open this link in a new window

MRI Resources 
Artifacts - Mobile MRI Rental - NMR - Developers - Spectroscopy - Distributors
 
Penetration Panel
 
This is the point of penetration by the MR system cables into the RF room. This panel contains filters and other connections required to provide communication between the scan room and the rest of the system without allowing interference to pass.
spacer
Searchterm 'MR System' was also found in the following services: 
spacer
News  (345)  Resources  (74)  Forum  (2)  
 
Philips Medical SystemsMRI Resource Directory:
 - Manufacturers -
 
www.medical.philips.com/main/products/mri/index.wpd Philips Medical System is the diagnostics business of Royal Philips Electronics of the Netherlands, one of the world's biggest electronics companies and Europe's largest. Philips is quoted on the NYSE (symbol: PHG), London, Frankfurt, Amsterdam and other stock exchanges. On October 19, 2001, Philips Medical Systems completed a 3-year acquisition strategy through its purchase of Marconi Medical Systems. Marconi Medical Systems offered leading multislice CT, MRI, and Nuclear Gamma Camera systems to medical institutions around the world. As well as new 3.0T developments, Philips is also in collaboration with researchers at the University of Nottingham, with the intention of developing an ultrahigh field strength clinical 7.0T whole body MR system.

MRI Scanners:

Contact Information
MAIL
Philips Medical Systems
3000 Minuteman Road
Andover, MA 01810-1099
USA
PHONE
+1-978-687-1501
E-MAIL ASIA PACIFIC
spacer

• View the DATABASE results for 'Philips Medical Systems' (14).Open this link in a new window


• View the NEWS results for 'Philips Medical Systems' (12).Open this link in a new window.
 
Further Reading:
  News & More:
RSNA update on new MRI technology(.pdf)
February 2006   by www.magnet-mri.org    
MRI Resources 
Corporations - Non-English - Shoulder MRI - Research Labs - MRI Physics - Chemistry
 
Preamplifier
 
A device that amplifies very low-level signals. A preamplifier is generally placed close to its signal source and has a very low noise figure as it is the principal determinant of electronic noise within the system. Preamplifiers used in NMR systems usually have a 50 ohm input impedance, and require a matching network to interface to the RF coil, although preamplifiers with high input impedance may be used with surface coils. Such devices typically use a field effect transistor (FET) as their input stage.
spacer

• View the DATABASE results for 'Preamplifier' (5).Open this link in a new window

MRI Resources 
Manufacturers - Used and Refurbished MRI Equipment - Coils - Absorption and Emission - Jobs pool - Contrast Agents
 
previous      16 - 20 (of 24)     next
Result Pages : [1 2 3 4 5]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



MRI is trending to low field magnets :
reduced costs will lead to this change 
AI will close the gap to high field 
only in remote areas 
is only temporary 
never 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 28 April 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]