Foreign BodiesMRI Resource Directory:
 - MRI Accidents -
 
mri safety guidance
MRI Safety Guidance
Occult incorporated ferromagnetic foreign bodies are dangerous, in particular those close to the eyes. The patient's history may help because many patients do not remember such accidents. In case of doubt, X-rays should be taken prior to MR imaging.
spacer
• For this and other aspects of MRI safety see our InfoSheet about MRI Safety.
• Patient-related information is collected in our MRI Patient Information.

MRI Safety Resources 
Cochlear Implant - Pregnancy - Safety Training - Pacemaker - Shielding
 
Gd-DTPA Labeled DextranInfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.
 
Short name:(Gd-DTPA)n-dextran, central moiety: Gd2+
Gd-DTPA labeled dextran is a substance that has been tested as a blood pool agent (intravascular MRI contrast agent). Dextran is a polysaccharide and has labeled with 15 Gd-DTPA moieties a higher T1 relaxivity than unbound Gd-DTPA, compared with a high safety level.

See also Intravascular Contrast Agents, Blood Pool Agents.
spacer

• View the DATABASE results for 'Gd-DTPA Labeled Dextran' (2).Open this link in a new window

 
Further Reading:
  Basics:
Evaluation of Gd-DTPA-labeled dextran as an intravascular MR contrast agent: imaging characteristics in normal rat tissues
   by radiology.rsnajnls.org    
MRI Resources 
Health - Contrast Agents - Spine MRI - Pacemaker - Veterinary MRI - Education
 
Helium
 
The element helium (He) was discovered 1868 when P.J.C. Janssen and N. Lockyer detected a new line in the solar spectrum during the solar eclipse. Lockyer and E. Frankland suggested the name helium (Gr. Helios, the sun) for the new element. In 1895, helium was discovered in the uranium mineral cleveite and in 1907 it was found out that alpha particles are helium nuclei.
Properties: Helium belongs to the noble gases, is colorless, odorless, and occurs in two naturally isotopes, helium 3 and helium 4. As an inert gas, helium does not react chemically largely and don't burns. Helium 4 makes up over 99% of naturally occurring helium atoms. Helium is extracted from natural gas e.g. present in various radioactive minerals as a decay product. Deposits and sources are in the USA, Poland, the USSR, and a few in India. The rare deposits and increased consumption lead to a shortage of this gas.
K. Onnes worked for many years to liquefy helium, which persisted as a gas to the lowest temperature. Helium does not freeze at atmospheric pressure. The density of helium vapor at his boiling point of 4.2 Kelvin is very high, with the vapor expanding greatly when heated to room temperature. Nb, Tc, Pb, La, V, and Ta are superconductors at liquid helium temperature. Liquid helium is commonly used as a cryogen for superconducting magnets. A rapid evaporation of the cryogen is named Quench. See also Quenching.
mri safety guidance
MRI Safety Guidance
Cryogenic liquids and their associated cold vapors can produce effects on the skin similar to a thermal burn and can cause frostbite. Prolonged breathing of extremely cold gases may damage the lungs and in absence of enough air or oxygen, asphyxiation and death can occur. Unprotected skin can stick to very cold metal (e.g. cooled by liquid helium) and then tear when pulled away.
spacer

• View the DATABASE results for 'Helium' (43).Open this link in a new window


• View the NEWS results for 'Helium' (2).Open this link in a new window.
 
Further Reading:
  Basics:
Superfluid helium-4
Monday, 12 February 2018   by en.wikipedia.org    
Cryogenic Liquids and their Hazards
   by www.ccohs.ca    
Liquid Helium
   by hyperphysics.phy-astr.gsu.edu    
  News & More:
Renergen surges after xceptionalâ„¢ helium concentration reports
Monday, 29 March 2021   by www.businesslive.co.za    
Not just balloons: Helium shortage may deflate MRIs, airbags and research
Friday, 3 May 2019   by eu.usatoday.com    
Liquid helium, the lifeblood of MRI machines
Tuesday, 5 March 2019   by www.gasworld.com    
Preclinical Imaging Systems Reduce Environmental Impact
Monday, 4 November 2019   by www.itnonline.com    
Huge newfound deposit of helium will keep MRI scanners running
Monday, 27 June 2016   by www.newscientist.com    
Philips launches Ingenia Ambition X 1.5T MR with industry-first fully sealed magnet for more productive, helium-free operations
Tuesday, 11 September 2018   by www.philips.com    
Tech firms, medical research threatened by helium shortage
Thursday, 19 September 2013   by www.livemint.com    
How 9/11 Made The Global Helium Shortage Worse
Thursday, 3 July 2014   by www.popsci.com    
Cooling MRI magnets without a continuous supply of scarce helium
Tuesday, 13 August 2013   by www.wired.co.uk    
Searchterm 'Safety' was also found in the following services: 
spacer
News  (69)  Resources  (43)  Forum  (15)  
 
High Field MRI
 
The principal advantage of MRI at high field is the increase in signal to noise ratio. This can be used to improve anatomic and/or temporal resolution and reduce scan time while preserving image quality. MRI devices for whole body imaging for human use are available up to 3 tesla (3T). Functional MRI (fMRI) and MR spectroscopy (MRS) benefit significantly. In addition, 3T machines have a great utility in applications such as TOF MRA and DTI. Higher field strengths are used for imaging of small parts of the body or scientific animal experiments. Higher contrast may permit reduction of gadolinium doses and, in some cases, earlier detection of disease.
Using high field MRI//MRS, the RF-wavelength and the dimension of the human body complicating the development of MR coils. The absorption of RF power causes heating of the tissue. The energy deposited in the patient's tissues is fourfold higher at 3T than at 1.5T. The specific absorption rate (SAR) induced temperature changes of the human body are the most important safety issue of high field MRI//MRS.
Susceptibility and chemical shift dispersion increase like T1, therefore high field MRI occasionally exhibits imaging artifacts. Most are obvious and easily recognized but some are subtle and mimic diseases. A thorough understanding of these artifacts is important to avoid potential pitfalls. Some imaging techniques or procedures can be utilized to remove or identify artifacts.

See also Diffusion Tensor Imaging.

See also the related poll result: 'In 2010 your scanner will probably work with a field strength of'
Medical-Ultrasound-Imaging.comMagnetic Resonance Guided Focused Ultrasound,  High Intensity Focused Ultrasound
spacer

• View the DATABASE results for 'High Field MRI' (16).Open this link in a new window


• View the NEWS results for 'High Field MRI' (9).Open this link in a new window.
 
Further Reading:
  Basics:
Next-generation 7 T scanner ramps the resolution of brain MR imaging
Wednesday, 17 January 2024   by physicsworld.com    
A paired dataset of T1- and T2-weighted MRI at 3 Tesla and 7 Tesla
Thursday, 27 July 2023   by www.nature.com    
CLINICAL WHOLE BODY MRI AT 3.0 T(.pdf)
2001
Musculoskeletal MRI at 3.0 T: Relaxation Times and Image Contrast
Sunday, 1 August 2004   by www.ajronline.org    
  News & More:
How safe is 7T MRI for patients with neurosurgical implants?
Thursday, 17 November 2022   by healthimaging.com    
Impact of Magnetic Field Inhomogeneity on the Quality of Magnetic Resonance Images and Compensation Techniques: A Review
Saturday, 1 October 2022   by www.dovepress.com    
7-T clinical MRI of the shoulder in patients with suspected lesions of the rotator cuff
Friday, 7 February 2020   by eurradiolexp.springeropen.com    
A 100-hour MRI scan captured the most detailed look yet at a whole human brain
Monday, 8 July 2019   by www.sciencenews.or    
T2-Weighted Liver MRI Using the MultiVane Technique at 3T: Comparison with Conventional T2-Weighted MRI
Friday, 16 October 2015   by www.ncbi.nlm.nih.gov    
Ultra-high-field MRI reveals language centres in the brain in much more detail
Tuesday, 28 October 2014   by medicalxpress.com    
Turbo-FLASH Based Arterial Spin Labeled Perfusion MRI at 7 T
Thursday, 20 June 2013   by www.plosone.org    
High-Resolution, Spin-Echo BOLD, and CBF fMRI at 4 and 7 T(.pdf)
October 2002   by otg.downstate.edu    
Vascular Filters of Functional MRI: Spatial Localization Using BOLD and CBV Contrast
MRI Resources 
Supplies - Crystallography - MRI Technician and Technologist Jobs - RIS - Brain MRI - Cochlear Implant
 
Insulin PumpMRI Resource Directory:
 - Safety -
 
mri safety guidance
MRI Safety Guidance
Not necessarily a contraindication, but the examination may damage or impair it. An insulin pump can be disconnected easily for a period of time. Remove the pump while outside the 5 Gauss line, because the pump batteries and motor are magnetic.
spacer

• View the DATABASE results for 'Insulin Pump' (3).Open this link in a new window

MRI Resources 
Collections - Implant and Prosthesis pool - NMR - Safety Products - Hospitals - Safety Training
 
previous      31 - 35 (of 57)     next
Result Pages : [1]  [2 3 4 5 6 7 8 9 10 11 12]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



Next big thing in MRI will be :
AI 
remote operator 
personalized protocols 
helium-free 
molecular MRI 
portable MRI 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 28 April 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]