Magnetic Resonance - Technology Information Portal Welcome to MRI Technology
Info
  Sheets

Out-
      side
 



 
 'B0' 
SEARCH FOR    
 
  2 3 5 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Result : Searchterm 'B0' found in 1 term [] and 43 definitions []
previous     16 - 20 (of 44)     next
Result Pages : [1]  [2 3 4 5 6 7 8 9]
Searchterm 'B0' was also found in the following services: 
spacer
News  (1)  Forum  (4)  
 
Gadomer 17InfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
Short name: (Gd-DTPA)-17, 24 cascade polymer, generic name: Gadomer-17, 24, central moiety: Gd2+, relaxivity: r1=11.9, B0=1.0 T, r2=16.5, Dose: 0.05 mmol/kg
An intravascular macromolecular MRI contrast agent with positive enhancement under development (Bayer Schering Pharma AG) for MR angiography and tumor differentiation. The synthetic dendrimer with large molecular weight (17kD - limits agent to vascular space) is linked to Gadolinium. The renal excretion is slowed to intermediate molecular size. In MRA a longer lasting venous and arterial enhancement was seen with Gadomer-17 due to the particular pharmacokinetics of this agent.

See also Tumor Specific Agents, and Intravascular Contrast Agents.
spacer

• View the NEWS results for 'Gadomer 17' (1).Open this link in a new window.
 
Further Reading:
  News & More:
Combined MR lymphangiography and MR imaging-guided needle localization of sentinel lymph nodes using Gadomer-17.
2002
MRI Resources 
MRI Accidents - Anatomy - Service and Support - Mass Spectrometry - Quality Advice - Chemistry
 
Gadovist®InfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
Gadovist® is an extracellular, neutral macrocyclic (gadolinium (Gd) complex) MRI contrast agents for central nervous system indications, particularly suited for studies in which high doses are required or advantageous. Gadovist® (also Gadograf) was available in two concentrations, currently only Gadovist® 1.0 is marketed.
The product was approved in Switzerland in 1999 and in Germany in 2000. Gadovist® 1.0 is in USA currently in the drug development and approval process, particularly for magnetic resonance angiography.

WARNING: NEPHROGENIC SYSTEMIC FIBROSIS Gadolinium-based contrast agents increase the risk for nephrogenic systemic fibrosis (NSF) in patients with acute or chronic severe renal insufficiency (glomerular filtration rate less than 30 mL/min/1.73m2), or acute renal insufficiency of any severity due to the hepato-renal syndrome or in the perioperative liver transplantation period.

See also Paramagnetic Contrast Agents and Gadobutrol.
Drug Information and Specification
NAME OF COMPOUND
Gadobutrol, Gd-BT-DO3A
CENTRAL MOIETY
Gd2+
CONTRAST EFFECT
T1, Predominantly positive enhancement
r1=3.6, B0=1.0 T
PHARMACOKINETIC
Intravascular, extracellular, renal excretion
OSMOLALITY
557 and 1603 mosm/kgH2O
CONCENTRATION
1 mol/L
DOSAGE
0.1mmol/kg
PREPARATION
Finished product
INDICATION
Central nervous system / whole body
DEVELOPMENT STAGE
For sale / submit for approval
DISTRIBUTOR
See below
PRESENTATION
Vials of 15, 30 mL
DO NOT RELY ON THE INFORMATION PROVIDED HERE, THEY ARE
NOT A SUBSTITUTE FOR THE ACCOMPANYING PACKAGE INSERT!
Distribution Information
TERRITORY
TRADE NAME
DEVELOPMENT
STAGE
DISTRIBUTOR
USA
Gadovist®
Submit for approval
Japan
Gadovist®
EU
Gadovist®
for sale
Australia
Gadovist®
for sale
spacer

• View the DATABASE results for 'Gadovist®' (5).Open this link in a new window

 
Further Reading:
  Basics:
Important Drug Warning for Gadolinium-Based Contrast Agents
Wednesday, 12 September 2007   by www.ismrm.org    
Gadograf, Gadovist
Friday, 13 April 2007   by www.ema.europa.eu    
  News & More:
EMA's final opinion confirms restrictions on use of linear gadolinium agents in body scans
Friday, 21 July 2017   by www.ema.europa.eu    
FDA Drug Safety Communication: FDA warns that gadolinium-based contrast agents (GBCAs) are retained in the body; requires new class warnings
Tuesday, 19 December 2017   by www.fda.gov    
FDA approves Bayer's Gadavist® (gadobutrol) injection as the first magnetic resonance contrast agent for pediatric patients less than 2 years of age
Monday, 5 January 2015   by www.prnewswire.com    
New data presented at RSNA on use of Bayer's Gadavist® (gadobutrol) injection in children less than 2 years of age
Wednesday, 3 December 2014   by www.prnewswire.com    
MRI Resources 
IR - MRI Technician and Technologist Schools - Jobs - MR Guided Interventions - Contrast Enhanced MRI - Case Studies
 
GastroMARK®InfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
GastroMARK® belongs to the negative oral contrast agents (same as Lumirem®, another brand name for ferumoxsil). GastroMARK® is used to distinguish the loops of the bowel from other abdominal structures and physiology. When GastroMARK® is ingested, it flows through and darkens the stomach and the small intestine in 30 to 45 minutes. By more clearly identifying the intestinal loops, GastroMARK® improves visualization of adjacent abdominal tissues such as the pancreas.
Drug Information and Specification
NAME OF COMPOUND
Ferumoxsil, silicone-coated superparamagnetic iron oxide, USAN, AMI-121
CENTRAL MOIETY
Fe3+/Fe2+
CONTRAST EFFECT
T2*enhanced
r1=3.4, r2=3.8, B0=1.0T
PHARMACOKINETIC
Gastrointestinal
OSMOLALITY
250 mosm/kgH2O
CONCENTRATION
52.5mg Fe/300mL
DOSAGE
300 mL oral
PREPARATION
Finished product
INDICATION
Bowel marking
DEVELOPMENT STAGE
For sale
DISTRIBUTOR
See below
PRESENTATION
Bottles containing 300 mL
DO NOT RELY ON THE INFORMATION PROVIDED HERE, THEY ARE
NOT A SUBSTITUTE FOR THE ACCOMPANYING PACKAGE INSERT!
Distribution Information
TERRITORY
TRADE NAME
DEVELOPMENT
STAGE
DISTRIBUTOR
USA
GastroMARK®
For sale
spacer

• View the DATABASE results for 'GastroMARK®' (6).Open this link in a new window

 
Further Reading:
  Basics:
ferumoxsil, oral suspension GastroMARK GastroMARK ®
MATERIAL SAFETY DATA SHEET
   by dailymed.nlm.nih.gov    
Searchterm 'B0' was also found in the following services: 
spacer
News  (1)  Forum  (4)  
 
Gd-DTPA-PEGInfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.
 
Short name: Gd-DTPA-PEG, generic name: Gd-DTPA-PEG polymers, chemical compound: Gadolinium DTPA polyethylene glycol, central moiety: Gd2+, relaxivity: r1=6.0, B0=1.0 T
A substance under development (preclin.) as an intravascular MRI contrast agent for MR angiography and capillary permeability detection.
spacer
MRI Resources 
Resources - Online Books - Most Wanted - Journals - Bioinformatics - Coils
 
Gd-DTPA-PolylysineInfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.
 
Short name: PLLGd-DTPA, generic name: (Gd-DTPA)n-polylysine, chemical compound: Gd-DTPA poly(L-lysine-Gd-diethylenetriamine-N,N,N',N'',N''-pentaacetic acid), central moiety: Gd2+, relaxivity: r1=13.1, B0=0.23T
A polymeric MRI contrast agent under development (preclin., Bayer Schering Pharma AG, Berlin, Germany) with advantages in both MRA and in the differential diagnosis of tumors, particularly in perfusion studies of the myocardium and potential in MR lung perfusion. Dozens of the relatively small molecule Gd-DTPA is bound covalently to polylysine, a large molecular weight backbone. The stable, highly water-soluble agent does not diffuse through the endothelium of the vascular system; it is subject to renal elimination.
spacer

• View the DATABASE results for 'Gd-DTPA-Polylysine' (2).Open this link in a new window

MRI Resources 
Case Studies - Resources - Artifacts - Functional MRI - Spectroscopy - Education
 
previous      16 - 20 (of 44)     next
Result Pages : [1]  [2 3 4 5 6 7 8 9]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



New acceleration techniques will :
reduce scan times 
cause artifacts 
increase expenses 
be useful if you have a lot of experience 
doesn't do much 
never heard of 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 27 April 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]