 'Guerbet S.A.' 
SEARCH FOR    
 
  2 3 5 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Result : Searchterm 'Guerbet S.A.' found in 1 term [] and 6 definitions []
1 - 5 (of 7)     next
Result Pages : [1]  [2]
MRI Resources 
Non-English - Process Analysis - Quality Advice - Abdominal Imaging - MRI Accidents - Databases
 
Guerbet S.A.
 
www.guerbet.com/home_va.html The France-based Guerbet Group is highly specialized in contrast media for medical imaging. Its strategic goal is to be a key player in this market. Products include Dotarem (Magnetic Resonance Imaging) and Xenetix (X-ray Imaging).

Product Information
TRADE NAME
(LOCAL DISTRIBUTION)
FOR SALE FOR SALE /
DEVELOPMENT
DEVELOPMENT
Dotarem®
Endoremâ„¢
Lumirem®
Artirem®
Sinerem®
Vistaremâ„¢
P717
P760

Contact Information
MAIL Guerbet
Boite postale 50400
95943 Roissy
Charles de Gaulle Cedex
FRANCE
PHONE +33-1-45-91-50-00
FAX +33-1-45-91-51-99
ONLINE www.guerbet.com
spacer
 
• Share the entry 'Guerbet S.A.':  Facebook  Twitter  LinkedIn  

• View the NEWS results for 'Guerbet S.A.' (2).Open this link in a new window.
 
Further Reading:
  Basics:
Guerbet Completes Acquisition of Mallinckrodt’s Contrast Media and Delivery Systems Business
Sunday, 29 November 2015   by www.itnonline.com    
MRI Resources 
Collections - Spectroscopy - Bioinformatics - Mass Spectrometry - Process Analysis - MRI Technician and Technologist Jobs
 
Artirem®InfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
Artirem®, the arthrography-specific contrast agent for MRI is a dilute form of Dotarem® with a less concentration of Gd (1:200). Artirem® has to be injected directly into the joints for better visualization and delimitation, of the ligament and tendon structures in particular.

Drug Information and Specification
NAME OF COMPOUND Gadoterate meglumine, Gd-DOTA
DEVELOPER Guerbet S.A.
CENTRAL MOIETY Gd2+
CONTRAST EFFECT T1, Predominantly positive enhancement
RELAXIVITY r1=3.4, r2=4.8, B0=1.0T
PHARMACOKINETIC Intravascular, extracellular, renal excretion
CONCENTRATION 0,0025 mmol/ml
PREPARATION Finished product
INDICATION Arthrography
DEVELOPMENT STAGE For sale
DISTRIBUTOR See below
PRESENTATION Pre-filled syringes of 20 mL
DO NOT RELY ON THE INFORMATION PROVIDED HERE, THEY ARE NOT A SUBSTITUTE FOR THE ACCOMPANYING PACKAGE INSERT

Distribution Information
TERRITORY TRADE NAME DEVELOPMENT
STAGE
DISTRIBUTOR
EU Dotarem® for sale Guerbet S.A.
France, Switzerland Artirem® for sale Guerbet S.A.
Australia Dotarem® for sale

spacer

• View the DATABASE results for 'Artirem®' (4).Open this link in a new window

MRI Resources 
Databases - Claustrophobia - Pregnancy - MRI Physics - Jobs - Anatomy
 
Dotarem®InfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
Dotarem® is a paramagnetic ionic MRI contrast agent. Extracellular contrast agents like Dotarem®, can be bolus injected because of the relatively low rate of side effects. This contrast medium is useable to enhance signal intensity in magnetic resonance imaging for intracranial and spinal lesions with an abnormal blood brain barrier or abnormal vascularity, and in whole body imaging.
WARNING: NEPHROGENIC SYSTEMIC FIBROSIS Gadolinium-based contrast agents increase the risk for nephrogenic systemic fibrosis (NSF) in patients with acute or chronic severe renal insufficiency (glomerular filtration rate less than 30 mL/min/1.73m2), or acute renal insufficiency of any severity due to the hepato-renal syndrome or in the perioperative liver transplantation period.

Drug Information and Specification
NAME OF COMPOUND Gadoterate meglumine, Gd-DOTA
DEVELOPER Guerbet S.A.
CENTRAL MOIETY Gd2+
CONTRAST EFFECT T1, Predominantly positive enhancement
RELAXIVITY r1=3.4, r2=4.8, B0=1.0T
PHARMACOKINETIC Intravascular, extracellular, renal excretion
OSMOLALITY 1350 mosm/kgH2O
CONCENTRATION 0.5 mol/L
DOSAGE 0.1 mmol/kg / 0.2mL/kg
PREPARATION Finished product
INDICATION Neuro/whole body
DEVELOPMENT STAGE For sale
DISTRIBUTOR See below
PRESENTATION Vials of 5, 10, 15, 20mL
Pre-filled syringes of 15 and 20 mL
DO NOT RELY ON THE INFORMATION PROVIDED HERE, THEY ARE NOT A SUBSTITUTE FOR THE ACCOMPANYING PACKAGE INSERT

Distribution Information
TERRITORY TRADE NAME DEVELOPMENT
STAGE
DISTRIBUTOR
EU Dotarem® for sale Guerbet S.A.
France, Switzerland Artirem® for sale Guerbet S.A.
Australia Dotarem® for sale

spacer

• View the DATABASE results for 'Dotarem®' (7).Open this link in a new window

 
Further Reading:
  Basics:
Important Drug Warning for Gadolinium-Based Contrast Agents
Wednesday, 12 September 2007   by www.ismrm.org    
  News & More:
Guerbet to Exhibit Recently U.S. Approved Imaging Agents at 100 Year Anniversary of RSNA
Thursday, 13 November 2014   by money.cnn.com    
MRI Resources 
Nerve Stimulator - Breast MRI - Knee MRI - Journals - PACS - Coils
 
Endorem™InfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
A brand name for ferumoxide (same as Feridex®)
Endorem™ is a black to reddish-brown aqueous colloid of superparamagnetic iron oxide associated with dextran for intravenous administration as a MRI contrast medium for the detection of liver lesions that are associated with an alteration in the RES.
Endorem™ is taken up by macrophages, found only in healthy liver cells but not in most tumors. Tissues such as metastases, primary liver cancer, cysts and various benign tumors, adenomas and hyperplasia retain their native signal intensity, so the contrast between normal and abnormal tissue is increased.
See also Ferumoxide.

Drug Information and Specification
NAME OF COMPOUND Dextran-coated ferumoxide, Ami-25
DEVELOPER AMAG Pharmaceuticals, Inc., Guerbet S.A.
CENTRAL MOIETY Fe2+/Fe3+
CONTRAST EFFECT T2, predominantly negative enhancement
RELAXIVITY r1=40.0, r2=160, B0=0.47T
PHARMACOKINETIC RES-directed
OSMOLALITY 340 mosm/kgH2O
CONCENTRATION 11.2mg Fe/ml
DOSAGE 15 µmol Fe/kg
PREPARATION Suspend in an isotonic glucose solution
INDICATION Liver
DEVELOPMENT STAGE For sale
DISTRIBUTOR See below
PRESENTATION Ampoule of 8 mL
DO NOT RELY ON THE INFORMATION PROVIDED HERE, THEY ARE NOT A SUBSTITUTE FOR THE ACCOMPANYING PACKAGE INSERT

Distribution Information
TERRITORY TRADE NAME DEVELOPMENT
STAGE
DISTRIBUTOR
USA Feridex I.V. for sale Bayer HealthCare Pharmaceuticals
Japan Feridex® for sale Eiken Chemical Co., Ltd.
EU
Brazil
Endorem™ for sale Guerbet S.A.
Argentina Feridex I.V. for sale Temis-Lostaló
South Korea Feridex I.V. for sale TaeJoon Pharmaceuticals
Israel Feridex I.V. for sale Discotrade
China Feridex I.V. for sale Pharmagenesis, Inc.

spacer

• View the DATABASE results for 'Endorem™' (5).Open this link in a new window

 
Further Reading:
  News & More:
MAGNETIC RESONANCE IMAGING OF FOCAL LIVER LESIONS(.pdf)
2002
MRI Resources 
Spectroscopy - Databases - General - Most Wanted - Jobs - Quality Advice
 
Feridex®InfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
A brand name for ferumoxide (same as Endorem™)
Feridex® is a sterile aqueous colloid of superparamagnetic iron oxide associated with dextran for intravenous administration as a MRI contrast medium for the detection of liver lesions that are associated with an alteration in the RES.
Feridex® is taken up by macrophages, found only in healthy liver cells but not in most tumors. Tissues such as metastases, primary liver cancer, cysts and various benign tumors, adenomas and hyperplasia retain their native signal intensity, so the contrast between normal and abnormal tissue is increased. Feridex® is a black to reddish-brown aqueous colloid.
See also Ferumoxide.

In November 2008, AMAG Pharmaceuticals, Inc. decided to discontinue the manufacturing of Feridex.


Drug Information and Specification
NAME OF COMPOUND Dextran-coated ferumoxide, Ami-25
DEVELOPER AMAG Pharmaceuticals, Inc.
CENTRAL MOIETY Fe2+/Fe3+
CONTRAST EFFECT T2, predominantly negative enhancement
RELAXIVITY r1=40.0, r2=160, B0=0.47T
PHARMACOKINETIC RES-directed
OSMOLALITY 340 mosm/kgH2O
CONCENTRATION 11.2mg Fe/ml
DOSAGE 15 µmol Fe/kg
PREPARATION Suspend in an isotonic glucose solution
INDICATION Liver
DEVELOPMENT STAGE For sale
DISTRIBUTOR See below
PRESENTATION Ampoule of 8 mL
DO NOT RELY ON THE INFORMATION PROVIDED HERE, THEY ARE NOT A SUBSTITUTE FOR THE ACCOMPANYING PACKAGE INSERT

Distribution Information
TERRITORY TRADE NAME DEVELOPMENT
STAGE
DISTRIBUTOR
USA Feridex I.V. - -
Japan Feridex® for sale? Eiken Chemical Co., Ltd.
EU
Brazil
Endorem™ for sale Guerbet S.A.
Argentina Feridex I.V. for sale? Temis-Lostaló
South Korea Feridex I.V. for sale? TaeJoon Pharmaceuticals
Israel Feridex I.V. for sale? Discotrade
China Feridex I.V. for sale? Pharmagenesis, Inc.

spacer

• View the DATABASE results for 'Feridex®' (9).Open this link in a new window

 
Further Reading:
  Basics:
AMAG Pharmaceuticals Inc. Q4 2008 Earnings Call Transcript
Friday, 27 February 2009   by seekingalpha.com    
Feridex Prescribing Information(.pdf)
   by berlex.bayerhealthcare.com    
  News & More:
MAGNETIC RESONANCE IMAGING OF FOCAL LIVER LESIONS(.pdf)
2002
MRI Resources 
Equipment - Shoulder MRI - Contrast Enhanced MRI - Musculoskeletal and Joint MRI - Portals - Service and Support
 
     1 - 5 (of 7)     next
Result Pages : [1]  [2]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?  



In 2020 your scanner will probably work with a field strength of :
lower 
1T 
1.5T 
2T 
3T 
7T 
higher 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • US-TIP • The-Medical-Market
Copyright © 2003 - 2016 SoftWays. All rights reserved. [ 26 June 2017]
Terms of Use | Privacy Policy | Advertising