Magnetic Resonance - Technology Information Portal Welcome to MRI Technology
Info
  Sheets

Out-
      side
 



 
 'Arc' 
SEARCH FOR    
 
  2 3 5 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Result : Searchterm 'Arc' found in 6 terms [] and 60 definitions []
previous     51 - 55 (of 66)     next
Result Pages : [1 2]  [3 4 5 6 7 8 9 10 11 12 13 14]
Searchterm 'Arc' was also found in the following services: 
spacer
News  (761)  Resources  (154)  Forum  (48)  
 
MetalloporphyrinsInfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.
 
Porphyrins occur naturally in plants and animals. All porphyrin molecules feature an aromatic macrocycle ring with a central binding site. This site accommodates transition metals, which are held in place by inward-facing nitrogen atoms. Metalloporphyrins have usually a low toxicity and a potential of a selective uptake in tumors or necrosis. These properties are advantageous for a use as MRI tumor specific agents with positive enhancement. These contrast agents enhance tumors on T1 weighted sequences, which are isointense to surrounding tissues. Porphyrin-based compounds have also necrosis avid properties; they can depict the extent of myocardial infarction as defined by histopathology.
Metalloporphyrins are also used in photodynamic therapy of tumors. The compounds contain a 'lone star' metal atom at the center of the ring and are 'bigger than the average porphyrin'. They contain five N atoms in the central chelating core and this allows them to form complexes with large trivalent lanthanide metals, which have useful cancer therapy properties.

See also Classifications, Characteristics, etc., Gadophrin, MnIIITPPS4, Necrosis Avid Contrast Agent.
spacer
 
Further Reading:
  Basics:
Relaxometric Investigation of Functional Group Placement on MnTPP Derivatives Supports the Role of the Molecular Electrostatic Potential Maps as a Tool to Design New Metalloporphyrins with Larger Relaxivities(.pdf)
   by www.mdpi.org    
Noninvasive Measurements of Infarct Size After Thrombolysis With a Necrosis-Avid MRI Contrast Agent
1999   by circ.ahajournals.org    
Searchterm 'Arc' was also found in the following services: 
spacer
Radiology  (25) Open this link in a new windowUltrasound  (65) Open this link in a new window
Monocrystalline Iron Oxide NanoparticleInfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.
 
Short name: MION, central moiety: Fe3+/Fe2+, relaxivity: r1=3.7, r2=6.5, B0=0.47T
MIONs are under development (preclin.) as contrast agents (taken up by the RES) for MR angiography, MR lymphography, tumor detection and detection of infarctioned tissue. Also called monodisperse iron oxide nanoparticles or nanocompounds.
spacer

• View the DATABASE results for 'Monocrystalline Iron Oxide Nanoparticle' (3).Open this link in a new window

 
Further Reading:
  Basics:
Biomedical scientist to test nanoparticles as early cancer detection agent
Monday, 28 October 2002
  News & More:
Turning up the heat on cancer
Thursday, 22 November 2007   by www.rsc.org    
Vascular Filters of Functional MRI: Spatial Localization Using BOLD and CBV Contrast
MRI Resources 
Crystallography - Contrast Agents - Shoulder MRI - Safety Products - Mobile MRI Rental - Calculation
 
MultiHance®InfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
MultiHance® is a paramagnetic contrast agent for use in diagnostic magnetic resonance imaging (MRI) of the liver and central nervous system. MultiHance® is a small molecular weight chelate, which tightly binds the Gd atom. The substance is excreted partly by the kidneys, partly by the biliary system, which is especially unique.
MultiHance® is indicated, for the detection of focal liver lesions in patients with known or suspected primary liver cancer (e.g. hepatocellular carcinoma) or metastatic disease.
MultiHance® is also indicated in brain MRI and spine MRI where it improves the detection of lesions and provides diagnostic information additional to that obtained with unenhanced MRI.
Gd-BOPTA-enhanced MRA can provide superior vascular signal intensity and SNR, as compared with Gd-DTPA, due to its higher relaxivity, even at lower doses.
1 ml of solution MultiHance® contains: (0.5M) gadobenate dimeglumine 529 mg = gadobenic acid 334 mg + meglumine 195 mg. Viscosity at 37°C: 5.3 mPa

WARNING: NEPHROGENIC SYSTEMIC FIBROSIS Gadolinium-based contrast agents increase the risk for nephrogenic systemic fibrosis (NSF) in patients with acute or chronic severe renal insufficiency (glomerular filtration rate less than 30 mL/min/1.73m2), or acute renal insufficiency of any severity due to the hepato-renal syndrome or in the perioperative liver transplantation period.
Drug Information and Specification
NAME OF COMPOUND
Gadobenate dimeglumine, Gd-BOPTA, E7155
DEVELOPER
CENTRAL MOIETY
Gd2+
CONTRAST EFFECT
T1, predominantly positive enhancement
r1=9.7, r2=12.5, B0=0.5 T
PHARMACOKINETIC
Extracellular, hepatobiliary
1970 mosm/kg
CONCENTRATION
334 mg/ml
DOSAGE
0.05 mmol/kg for Liver MRI
0.1 mmol/kg for CNS MRI
PREPARATION
Solution for injection
INDICATION
CNS, Liver MRI
DEVELOPMENT STAGE
For sale
DISTRIBUTOR
See below
PRESENTATION
Vials of 5, 10, 15 and 20 mL, 50 and 100 mL Multipacks (Pharmacy Bulk Package)
DO NOT RELY ON THE INFORMATION PROVIDED HERE, THEY ARE
NOT A SUBSTITUTE FOR THE ACCOMPANYING PACKAGE INSERT!
Distribution Information
TERRITORY
TRADE NAME
DEVELOPMENT
STAGE
DISTRIBUTOR
EU
MultiHance®
for sale
USA
MultiHance®
for sale
Australia
MultiHance®
for sale
spacer

• View the DATABASE results for 'MultiHance®' (9).Open this link in a new window


• View the NEWS results for 'MultiHance®' (1).Open this link in a new window.
 
Further Reading:
  Basics:
Important Drug Warning for Gadolinium-Based Contrast Agents
Wednesday, 12 September 2007   by www.ismrm.org    
MultiHance Package Insert(.pdf)
   by www.fda.gov    
  News & More:
FDA Expands Pediatric Age Range for MultiHance Contrast Agent
Tuesday, 30 January 2018   by www.empr.com    
MAGNETIC RESONANCE IMAGING OF FOCAL LIVER LESIONS(.pdf)
2002
BRACCO DIAGNOSTICS' MULTIHANCE EARNS FDA APPROVAL
Wednesday, 24 November 2004   by salesandmarketingnetwork.com    
Searchterm 'Arc' was also found in the following services: 
spacer
News  (761)  Resources  (154)  Forum  (48)  
 
Necrosis Avid Contrast AgentInfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
(NACA) Some porphyrin (e.g. Gadophrin-2) and non-porphyrin (e.g. CEIII-60) paramagnetic chelates are able to specifically accumulate in nonviable tissues and can be applied as a MRI contrast agent for acute myocardial infarction and therapeutic necrosis. This function of necrosis avid contrast agents is a unique pathological targetability. These agents can also be exploited for multipurpose applications, because NACAs also bear other common properties including early systemic distribution, albumin binding, hepatocellular uptake and renal elimination.

See also the related poll result: 'The development of contrast agents in MRI is'
spacer

• View the DATABASE results for 'Necrosis Avid Contrast Agent' (9).Open this link in a new window


• View the NEWS results for 'Necrosis Avid Contrast Agent' (1).Open this link in a new window.
 
Further Reading:
  Basics:
Tumor-targeted MR Contrast Agents: Hype or Future Hope?
November 2004   by radiology.rsnajnls.org    
  News & More:
Rockland Technimed: Tissue Viability Imaging
Saturday, 15 December 2007   by www.onemedplace.com    
Searchterm 'Arc' was also found in the following services: 
spacer
Radiology  (25) Open this link in a new windowUltrasound  (65) Open this link in a new window
NitroxidesInfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.
 
Nitroxide radicals (or nitroxyl spin labels) are stable organic compounds with theoretical potential for use as a paramagnetic MRI contrast agent. Similar to gadolinium they have an unpaired electron, a property that provides enhancement in T1 based MRI, and a comparable pharmacokinetic. Depending on their structure and chemical bonding, different nitroxides formula may have the potential for use as cardiovascular imaging agents, to enhance the MR imaging on joints (e.g., dendrimer-linked nitroxides have a strong affinity for cartilage), to evaluate brain tumors and infarction, and as a contrast enhancement agent of body/abdominal NMR imaging. Nitroxides are rapidly enzymatically reduced in tissues to products that do not enhance the NMR signal, which can be a problem for MR imaging. In animal experiments with EPRI (electron paramagnetic resonance imaging), tissue redox studies show differences between tumors and normal tissues, which reflect their respective redox status consistent with the reduction/clearance of nitroxides.
spacer

• View the DATABASE results for 'Nitroxides' (2).Open this link in a new window

 
Further Reading:
  News & More:
Electron Paramagnetic Resonance for Small Animal Imaging Applications
   by pet.radiology.uiowa.edu    
MRI Resources 
Homepages - Universities - Online Books - Research Labs - Brain MRI - Musculoskeletal and Joint MRI
 
previous      51 - 55 (of 66)     next
Result Pages : [1 2]  [3 4 5 6 7 8 9 10 11 12 13 14]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



How AI will impact MRI :
only diagnostics 
saving time 
reducing cost 
makes planning obsolete 
reduce human knowledge 
not at all 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 5 May 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]