Magnetic Resonance - Technology Information Portal Welcome to MRI Technology
Info
  Sheets

Out-
      side
 



 
 'Noise' 
SEARCH FOR    
 
  2 3 5 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Result : Searchterm 'Noise' found in 12 terms [] and 72 definitions []
previous     61 - 65 (of 84)     next
Result Pages : [1 2 3]  [4 5 6 7 8 9 10 11 12 13 14 15 16 17]
Searchterm 'Noise' was also found in the following services: 
spacer
News  (14)  Forum  (13)  
 
Partial Volume ArtifactInfoSheet: - Artifacts - 
Case Studies, 
Reduction Index, 
etc.MRI Resource Directory:
 - Artifacts -
 
Quick Overview
Artifact Information
NAME
Partial volume
DESCRIPTION
Loss of contrast between two adjacent tissues
REASON
Insufficient resolution
HELP
Thinner slices
The Partial Volume Artifact is caused by imaging voxel containing two different tissues and therefore possessing a signal average of both tissues.
mri safety guidance
Image Guidance
Take thinner slices (smaller voxel), but this may result in poorer signal to noise ratio in the image.

See Partial Volume Effect.
spacer
 
• Related Searches:
    • Water Fat Shift
    • Image Quality
    • Spatial Resolution
    • Multiple Overlapping Thin Slab (Slice) Acquisition
    • Voxel
 
Further Reading:
  Basics:
MRI GLOSSARY
   by fonar.com    
Searchterm 'Noise' was also found in the following services: 
spacer
Radiology  (15) Open this link in a new windowUltrasound  (15) Open this link in a new window
Partial Volume EffectInfoSheet: - Artifacts - 
Case Studies, 
Reduction Index, 
etc.
 
The partial volume effect is the loss of contrast between two adjacent tissues in an image caused by insufficient resolution so that more than one tissue type occupies the same voxel (or pixel). That may induce a partial volume artifact, dependent on the size of the image voxel. If fat and water spins occupy the same voxel, their signals interfere destructively. A small amount of water signal may be eliminated by a larger lipid signal from the same voxel, resulting in a voxel that appears to contain only lipid. The partial volume effect is minimal with thin slice thickness and sufficiently high resolution, so that fat and water or other different structures are unlikely to occupy the same voxel.
mri safety guidance
Image Guidance
Take thinner slices, and higher resolution (smaller voxel), but remain this may result in poorer signal to noise ratio in the image.
spacer

• View the DATABASE results for 'Partial Volume Effect' (2).Open this link in a new window

MRI Resources 
Veterinary MRI - Contrast Agents - Databases - - Liver Imaging - Brain MRI
 
Phase Encoded Motion ArtifactInfoSheet: - Artifacts - 
Case Studies, 
Reduction Index, 
etc.MRI Resource Directory:
 - Artifacts -
 
Quick Overview
Please note that there are different common names for this artifact.
Artifact Information
NAME
Phase encoded motion, motion, phase effect
DESCRIPTION
Blurring and ghosting
REASON
Movement of the imaged object
HELP
Compensation techniques, more averages, anti spasmodic, presaturation
This artifact is caused by movements of the patient or organic processes taking place in the body of the patient. The artifact appears as bright noise, repeating densities or ghosting in the phase encoding direction.
mri safety guidance
Image Guidance
There are different solutions for reduction of phase encoded motion artifacts.
Cardiac and respiratory gating, breath holding, sedation of the patient, presaturation pulses for flow artifacts (e.g. arterial pulsation, breathing), fast imaging sequences, etc.

See also Motion Artifact, Ghosting Artifact, Motion Compensation Pulse Sequences and Artifact Reduction - Motion.
spacer

• View the DATABASE results for 'Phase Encoded Motion Artifact' (5).Open this link in a new window

Searchterm 'Noise' was also found in the following services: 
spacer
News  (14)  Forum  (13)  
 
PhonForum -
related threads
 
A logarithmic measure of sound loudness closely related to the decibel. The unit decibel is used for objective measurements, that means, they measure the actual pressure of the sound waves as recorded using a microphone. The unit phon is used for subjective measurements, that means, measurements made using the ears of a human listener.
A sound has the loudness 'p' phon if it seems to the listener to be equal in loudness to the sound of a pure tone of the frequency 1 kilohertz and strength 'p' decibel. A measurement in phons will be similar to a measurement in decibel, but not identical, since the perceived loudness of a sound depends on the distribution of frequencies in the sound as well as the pressure of the sound waves. In the U.S., sound loudness is frequently measured in sones rather than phons: a sound of loudness 's' sones has loudness 10 log2 s + 40 phons.

See also Acoustic Noise.
spacer

• View the DATABASE results for 'Phon' (48).Open this link in a new window


• View the NEWS results for 'Phon' (2).Open this link in a new window.
Searchterm 'Noise' was also found in the following services: 
spacer
Radiology  (15) Open this link in a new windowUltrasound  (15) Open this link in a new window
Quality Factor
 
The quality factor (Q) applies to any resonant circuit component; most often the quality factor of the coil determines the overall Q of the circuit.
Inversely related to the fraction of the energy in an oscillating system lost in one oscillation cycle. Q is inversely related to the range of frequency over which the system will exhibit resonance.
In a parallel tuned circuit (such as used in a MR coil), the quality factor is defined as:
Q = vL/R
where L is the coil inductance, R is the circuit resistance, and v is the angular frequency. Increasing quality factor results in improving the signal to noise ratio SNR by a factor √Q and also produces a sharper frequency response (decreased band width). The Q of a coil will depend on the circumstances under which it is measured, e.g. whether it is 'unloaded' (no patient) or 'loaded' (patient).
spacer

• View the DATABASE results for 'Quality Factor' (2).Open this link in a new window

MRI Resources 
Diffusion Weighted Imaging - Journals - Service and Support - Contrast Enhanced MRI - Libraries - Safety pool
 
previous      61 - 65 (of 84)     next
Result Pages : [1 2 3]  [4 5 6 7 8 9 10 11 12 13 14 15 16 17]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



Next big thing in MRI will be :
AI 
remote operator 
personalized protocols 
helium-free 
molecular MRI 
portable MRI 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 8 May 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]