Cr-HIDAInfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
Cr-HIDA (Chromium diethyl HIDA meglumine) is a substance with paramagnetic characteristics that has been tested in animals for the use as a hepatobiliary MRI contrast agent.

See also Hepatobiliary Contrast Agents, Paramagnetic Substance, Paramagnetism.
spacer
 
Further Reading:
  Basics:
MR-cholangiography with a double contrast technique.
Monday, 30 January 1989   by www.ncbi.nlm.nih.gov    
MRI Resources 
Patient Information - - Libraries - Lung Imaging - Blood Flow Imaging - Most Wanted
 
Domain Theory
 
A theory of magnetism, which assumes that groups of atoms produced by movement of electrons align themselves in groups called "domains" in magnetic materials.
spacer
 
Further Reading:
  Basics:
Magnetic domain
   by en.wikipedia.org    
MRI Resources 
Pediatric and Fetal MRI - Artifacts - RIS - MRI Training Courses - Manufacturers - Hospitals
 
Faraday Shield
 
In electromagnetism, the Faraday cage or shield is an application of Gauss's law, one of Maxwell's equations. Gauss's law describes the distribution of electrical charge on a conducting form, such as a sphere, a plane, a torus, etc. Intuitively, since like charges repel each other, charge will "migrate" to the surface of the conducting form, as described below. The application is named after physicist Michael Faraday, who built the first Faraday cage in 1836, to demonstrate his finding. A Faraday shield is used generally for any kind of electrostatic shielding.
In MRI, one use of the Faraday shield is the shielding of the scanning room, to block incoming radio frequency (RF) signals which would contaminate the send and received signals of the MRI scanner, and it suppresses RF signals, which would else pollute the environment around.
spacer

• View the DATABASE results for 'Faraday Shield' (5).Open this link in a new window

 
Further Reading:
  Basics:
Faraday's Law
   by hyperphysics.phy-astr.gsu.edu    
Faraday_shield
   by en.wikipedia.org    
  News & More:
Electrical eddy currents in the human body: MRI scans and medical implants
   by www.phy.olemiss.edu    
Searchterm 'Magnetism' was also found in the following service: 
spacer
News  (6)  
 
Gadolinium OxideInfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.
 
Gadolinium oxide (Gd2O3) is a prototype paramagnetic agent for contrast enhanced MRI. Gd2O3 particles have very high relaxivity. With its high magnetic moment, gadolinium reduces the relaxation time and enhance MR signal intensity. All gadolinium compounds are highly toxic. Very stable complexes are developed to eliminate the toxicity. See also Paramagnetic Substance, Paramagnetism, Paramagnetic Contrast Agents and Contrast Agents, the info sheet gives an overview and more in-dept information about different types of MRI Contrast media.
spacer

• View the DATABASE results for 'Gadolinium Oxide' (2).Open this link in a new window

 
Further Reading:
  Basics:
Gadolinium oxide nanoparticles enhance MRI contrast
Thursday, 29 September 2011   by nanotechweb.org    
  News & More:
Northern Rare Earth eyes medical device prospects
Thursday, 29 December 2016   by usa.chinadaily.com.cn    
MRI Resources 
Pediatric and Fetal MRI - Education - Calculation - Blood Flow Imaging - Online Books - Safety Training
 
MagnetForum -
related threads
 
A magnet is by definition an object with magnetic properties (magnetism) that attracts iron and produces a magnetic field. It can be a permanent magnet or an electromagnet.
Permanent magnets do not rely upon outside influences to generate their field. In permanent magnets are the atoms and molecules ordered in long range. The specific electron configuration and the distance of the atoms is what lead to this long range ordering. The electrons exist in a lower energy state if they all have the same orientation. Magnetic domains can be likened to microscopic neighborhoods in which there is a strong reinforcing interaction between particles, resulting in a high degree of order. The greater the degree of ordering within and between domains, the greater the resulting field will be. Long range ordering is one of the hallmarks of a ferromagnetic material.
A current carrying conductor for example a piece of wire, produces a magnetic field that encircles the wire. An electromagnet, in its simplest form, is a wire that has been coiled into one or more loops. This coil is known as a solenoid. The more loops of wire and the greater the current, the stronger the field will be.
Superconducting magnets are a special type of electromagnets, often used in MRI machines with high field strength.
spacer

• View the DATABASE results for 'Magnet' (669).Open this link in a new window


• View the NEWS results for 'Magnet' (315).Open this link in a new window.
 
Further Reading:
  Basics:
Magnetic Field
   by hyperphysics.phy-astr.gsu.edu    
  News & More:
Philips Signs Research Agreement to Explore New Magnet Technologies
Monday, 5 December 2022   by www.itnonline.com    
Impact of Magnetic Field Inhomogeneity on the Quality of Magnetic Resonance Images and Compensation Techniques: A Review
Saturday, 1 October 2022   by www.dovepress.com    
Magnetic seeds used to heat and kill cancer
Tuesday, 1 February 2022   by www.sciencedaily.com    
Harvard Scientists Create Nanoscale MRI
Monday, 28 April 2014   by www.meddeviceonline.com    
How Academic Research Solved the Puzzle of MRI and CAT Scanning
Monday, 21 April 2014   by www.engineering.com    
MRI Resources 
Case Studies - Shielding - Journals - Fluorescence - Homepages - Process Analysis
 
previous      11 - 15 (of 18)     next
Result Pages : [1]  [2 3 4]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



New acceleration techniques will :
reduce scan times 
cause artifacts 
increase expenses 
be useful if you have a lot of experience 
doesn't do much 
never heard of 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 30 April 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]