Baseline Correction
 
Postprocessing of the spectrum to suppress baseline deviations from zero that may be superimposed on desired spectral lines. These deviations may be due either to various instrumental effects or to very broad spectral lines.
spacer
Searchterm 'Spectra' was also found in the following service: 
spacer
Ultrasound  (29) Open this link in a new window
Convolution Differentiation
 
Convolution differentiation is a method of suppressing broad underlying spectral lines in order to emphasize narrower spectral lines. Strong smoothing of the spectrum (e.g., by severe negative exponential weighting of the time data) will suppress the narrow lines but minimally affect very broad ones; subtracting such a smoothed spectrum from the original will largely remove the contributions from the broad lines. This provides a means of baseline correction.
spacer
MRI Resources 
Blood Flow Imaging - Devices - Pregnancy - Veterinary MRI - Health - Quality Advice
 
Echo Offset
 
Echo offset is the time setting of spin echo and gradient echo to be not coincident and to generate phase differences between different spectral line signals (e.g., water and fat). The echo offset is the product of the frequency line difference and the time difference (TD) in the echo times and is equal to the magnitude of the result of the phase difference between two spectral lines. Phases may not change linearly with echo offset time in the presence of a large field inhomogeneity. An echo offset excitation pulse sequence can be used in the magnetic field mapping method, to generate maps from which the standard deviation of the phase difference can be calculated.
spacer
 
Further Reading:
  News & More:
T1rho-prepared balanced gradient echo for rapid 3D T1rho MRI
Monday, 1 September 2008   by www.ncbi.nlm.nih.gov    
A short-TR single-echo spin-echo breath-hold method for assessing liver T2
Sunday, 10 December 2023   by link.springer.com    
Searchterm 'Spectra' was also found in the following services: 
spacer
News  (6)  Resources  (28)  
 
Full Width at Half Maximum
 
(FWHM) A commonly used measure of the width at half the maximum value of peaked functions such as spectral lines or slice profiles and important measure of the quality of an imaging device and its spatial resolution. As the name states, the FWHM is measured by identifying the points on the signal curve, which are half the maximum value. The horizontal distance between these two points is called the FWHM. For a spectral line, this will be proportional to 1/T2.
spacer

• View the DATABASE results for 'Full Width at Half Maximum' (3).Open this link in a new window

 
Further Reading:
  Basics:
Full width at half maximum
   by en.wikipedia.org    
  News & More:
Magnetic resonance-guided motorized transcranial ultrasound system for blood-brain barrier permeabilization along arbitrary trajectories in rodents
Thursday, 24 December 2015   by www.ncbi.nlm.nih.gov    
Searchterm 'Spectra' was also found in the following service: 
spacer
Ultrasound  (29) Open this link in a new window
Functional Brain MR SpectroscopyMRI Resource Directory:
 - Functional MRI -
 
The use of MR spectroscopy for acquiring functional activation of the brain.
There are two possible approaches:
In the first, localized spectra of brain water are acquired and subtle changes in these spectra reflect the biophysical water environment. Changes in T2 due to deoxyhaemoglobin concentration may be detected in this way. The disadvantages of poor spatial resolution are to some extent offset by the high signal to noise ratio SNR of the spectroscopic data.
An alternative approach is to use MR spectroscopy directly to detect metabolites that are altered by brain activation. These include lactate and glucose. Such experiments have inherently poor spatial and temporal resolution, but do give a direct indication of the metabolic response of the brain to functional activation.
spacer
MRI Resources 
Directories - Breast MRI - Safety Training - Chemistry - Spine MRI - Jobs pool
 
previous      11 - 15 (of 49)     next
Result Pages : [1 2]  [3 4 5 6 7 8 9 10]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



MRI is trending to low field magnets :
reduced costs will lead to this change 
AI will close the gap to high field 
only in remote areas 
is only temporary 
never 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 5 May 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]