(T) Times between successive RF pulses used in pulse sequences. Particularly important are the inversion time (TI) in inversion recovery, and the time between 90° pulse and the subsequent 180° pulse to produce a spin echo, which will be approximately one half the spin echo time(TE). The time between repetitions of pulse sequences is the repetition time(TR).
spacer
MRI Resources 
Anatomy - Pacemaker - Most Wanted - Cochlear Implant - Lung Imaging - Spectroscopy
 
Motion Compensation Pulse SequencesInfoSheet: - Sequences - 
Intro, 
Overview, 
Types of, 
etc.MRI Resource Directory:
 - Sequences -
 
Pulse sequences, designed to be insensitive to flow, e.g. at every even echo, a spin echo sequence is not flow sensitive. Velocity compensation is achieved by using gradients, which are either symmetrical around a 180° pulse and switched on twice as is the case for motion compensated spin echo pulse sequences, or two antisymmetrical gradient lobes without 180° pulse, which is the way to produce a velocity compensated gradient echo pulse sequence.
The signal of the second echo (and all other even echoes) is independent of the velocity of the object. Thus, velocity-based motion effects stemming from the entire voxel or from spins within a voxel (intravoxel incoherent motion) are suppressed with such pulse sequences.
If higher order motion is relevant, as it may be in turbulent jets across valves, acceleration and jerk effects can also be compensated for by the use of appropriate combinations of gradient- and radio frequency pulses.
With the increasingly stronger gradients, echo times in MR systems can be shortened to the point at which effects other than velocity effects hardly ever become relevant.
spacer

• View the DATABASE results for 'Motion Compensation Pulse Sequences' (2).Open this link in a new window

 
Further Reading:
  News & More:
Patient movement during MRI: Additional points to ponder
Tuesday, 5 January 2016   by www.healthimaging.com    
Motion-compensation of Cardiac Perfusion MRI using a Statistical Texture Ensemble(.pdf)
June 2003   by www.imm.dtu.dk    
MRI Resources 
Jobs pool - IR - Supplies - MRI Centers - Mass Spectrometry - Sequences
 
Multi Echo Pulse SequenceInfoSheet: - Sequences - 
Intro, 
Overview, 
Types of, 
etc.MRI Resource Directory:
 - Sequences -
 
In standard SE MR imaging, each image line measured at each echo after the excitation 90° pulse is assigned to a different image, hence resulting in a multi echo pulse sequence.
spacer

• View the DATABASE results for 'Multi Echo Pulse Sequence' (2).Open this link in a new window

 
Further Reading:
  Basics:
Fast Spin Echo(.pdf)
Tuesday, 24 January 2006   by www.81bones.net    
Searchterm 'P Pulse' was also found in the following services: 
spacer
News  (13)  Resources  (11)  
 
Non-selective Pulse
 
This pulse affects all of the tissue within the transmitting coil. It is only used for MTC at a frequency distant from the Larmor frequency or if another method is selected to define slices like 3D acquisition.
spacer
MRI Resources 
Open Directory Project - Manufacturers - Examinations - Chemistry - Blood Flow Imaging - Liver Imaging
 
P/2 Pulse
 
spacer

• View the DATABASE results for 'P/2 Pulse' (2).Open this link in a new window

MRI Resources 
Stimulator pool - Databases - Pathology - Bioinformatics - Education - Spectroscopy pool
 
previous      11 - 15 (of 22)     next
Result Pages : [1]  [2 3 4 5]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



MRI is trending to low field magnets :
reduced costs will lead to this change 
AI will close the gap to high field 
only in remote areas 
is only temporary 
never 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 29 April 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]