From ONI Medical Systems, Inc.;
|
MSK-Extreme™ MRI system is a dedicated high field extremity imaging device, designed to provide orthopedic surgeons and other physicians with detailed diagnostic images of the foot, ankle, knee, hand, wrist and elbow, all with the clinical confidence and advantages derived from high field, whole body MRI units. The light weight (less than 650 kg) of the OrthOne System performs rapid patient studies, is easy to operate, has a patient friendly open environment and can be installed in a practice office or hospital, all at a cost similar to a low field extremity machine.
New features include a more powerful operating system that offers increased scan speed as well as a 160-mm knee coil with higher signal to noise ratio, and the option of a CD burner.
|
|
Device Information and Specification |
| CLINICAL APPLICATION |
Dedicated extremity imaging |
| CONFIGURATION |
Open MRI magnet |
| SURFACE COILS |
16 cm knee, 18 cm lower extremity;; 12.3 cm upper extremity, additional high resolution v-SPEC Coils: 80 mm, 100 mm, or 145 mm. |
| SPECTROSCOPY |
No |
| SYNCHRONIZATION |
No |
| PULSE SEQUENCES |
SE, FSE, GE2D, GE3D, Inversion recovery (IR), Driven Equilibrium, Fat Saturation (FS), STIR, MT, PD, Flow Compensation (FC), RF spoiling, MTE, No Phase Wrap (NPW) |
| IMAGING MODES |
Scout, single, multislice, volume |
| TR |
10-10,000ms; 1ms steps |
| TE |
5-150ms; 1 ms steps |
| SINGLE/MULTI SLICE |
2D less than 200 msec/image |
| FOV |
4cm-16cm |
| SLICE THICKNESS |
2D: 2mm-10mm/.1mm incr. |
| DISPLAY MATRIX |
Up to 1,000x1,000 |
| MEASURING MATRIX |
X/Y: 64-512; 2 pixel steps |
| PIXEL INTENSITY |
4,096 grey lvls; 256 lvls in 3D |
| SPATIAL RESOLUTION |
0.05mm |
| MAGNET TYPE |
Superconducting |
BORE DIAMETER or W x H |
28cm ID x 50cm L |
| MAGNET WEIGHT |
635 kg |
| H*W*D |
146 x 69 x 84 cm |
| POWER REQUIREMENTS |
115VAC, 1phase, 20A; 208VAC, 3 phase, 30A |
| COOLING SYSTEM TYPE |
LHe with 2 stage cold head |
| CRYOGEN USE |
Negligible |
| FIELD STRENGTH |
1.0 T |
| STRENGTH |
15 mT/m |
| 5-GAUSS FRINGE FIELD |
1.25m radial x 1.8m axial |
| SHIMMING |
Passive |
|
| | |
Further Reading: |
Basics:
|
| | |
|  |  |
| ONI Medical Systems, Inc. |  |
| |
|
Founded in June 1997, ONI is a privately held company headquartered in Wilmington, Massachusetts. ONI is focused on addressing the new healthcare economics by delivering the next generation of MRI machines: high field, low cost dedicated purpose systems. The company's first offering was the OrthOne™. Further developements lead to the MSK Extreme™, a 1.0 Tesla dedicated purpose MR system with v-SPEC™ Technology and DICOM Conformance for extremity applications.
MRI Related Product Line: |
|
|
Contact Information |
| MAIL |
ONI, Inc.
301 Ballardvale Street,
Suite 4
Wilmington, MA 01887
USA |
| PHONE |
+1-978-658-0020 |
| FAX |
+1-978-658-0898 |
| E-MAIL |
info@onicorp.com |
| ONLINE |
www.onicorp.com |
|
| | | | | | •• There are 4 news about 'ONI Medical Systems, Inc.'. | |
|  |
 |
MRI Resources |
|
| | | |  |  |
|
 |
|
 |
MRI Resources |
|
| | | |  |  | |
|  |  | 1 - 2 (of 2) Result Pages : [1] |
| |
|
| |
|
Look Ups
|
 |
Latest
News |
|
|
ADVERTISEMENT |
|
|
|
ADVERTISEMENT |
| |