Magnetic Resonance - Technology Information Portal Tuesday, 9 February 2010••
Info
  Sheets


Out-
      side
 
ADVERTISEMENT
ADVERTISEMENT

ADVERTISEMENT
ADVERTISEMENT

ADVERTISEMENT
ADVERTISEMENT

 
 'orthone' 
SEARCH FOR    
 
  2 3 5 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Result : Searchterm 'orthone' found in 0 term [] and 2 definitions []
1 - 2 (of 2)     
Result Pages : [1]
 bottom
MRI Resources  
Chemistry - MRI Physics - MRI Technician and Technologist Schools - General - Directories - Pediatric and Fetal MRI
 
MSK-Extreme™InfoSheet: - Devices -
Intro, 
Types of Magnets, 
Overview, 
etc.MRI Resource Directory:
 - Devices -
 
From ONI Medical Systems, Inc.;
www.onicorp.com/ MSK-Extreme™ MRI system is a dedicated high field extremity imaging device, designed to provide orthopedic surgeons and other physicians with detailed diagnostic images of the foot, ankle, knee, hand, wrist and elbow, all with the clinical confidence and advantages derived from high field, whole body MRI units. The light weight (less than 650 kg) of the OrthOne System performs rapid patient studies, is easy to operate, has a patient friendly open environment and can be installed in a practice office or hospital, all at a cost similar to a low field extremity machine.
New features include a more powerful operating system that offers increased scan speed as well as a 160-mm knee coil with higher signal to noise ratio, and the option of a CD burner.

Device Information and Specification
CLINICAL APPLICATION Dedicated extremity imaging
CONFIGURATION Open MRI magnet
SURFACE COILS 16 cm knee, 18 cm lower extremity;; 12.3 cm upper extremity, additional high resolution v-SPEC Coils: 80 mm, 100 mm, or 145 mm.
SPECTROSCOPY No
SYNCHRONIZATION No
PULSE SEQUENCES SE, FSE, GE2D, GE3D, Inversion recovery (IR), Driven Equilibrium, Fat Saturation (FS), STIR, MT, PD, Flow Compensation (FC), RF spoiling, MTE, No Phase Wrap (NPW)
IMAGING MODES Scout, single, multislice, volume
TR 10-10,000ms; 1ms steps
TE 5-150ms; 1 ms steps
SINGLE/MULTI SLICE 2D less than 200 msec/image
FOV 4cm-16cm
SLICE THICKNESS 2D: 2mm-10mm/.1mm incr.
DISPLAY MATRIX Up to 1,000x1,000
MEASURING MATRIX X/Y: 64-512; 2 pixel steps
PIXEL INTENSITY 4,096 grey lvls; 256 lvls in 3D
SPATIAL RESOLUTION 0.05mm
MAGNET TYPE Superconducting
BORE DIAMETER
or W x H
28cm ID x 50cm L
MAGNET WEIGHT 635 kg
H*W*D 146 x 69 x 84 cm
POWER REQUIREMENTS 115VAC, 1phase, 20A; 208VAC, 3 phase, 30A
COOLING SYSTEM TYPE LHe with 2 stage cold head
CRYOGEN USE Negligible
FIELD STRENGTH 1.0 T
STRENGTH 15 mT/m
5-GAUSS FRINGE FIELD 1.25m radial x 1.8m axial
SHIMMING Passive
Further Reading:
  Basics:
MSK Extreme with V-SPEC 1.0T PRODUCT OVERVIEWOpen this link in a new window
   by www.onicorp.com    
MSK Extreme Brochure(.pdf)Open this link in a new window
   by www.onicorp.com    
MSK Extreme SpecificationsOpen this link in a new window
   by www.onicorp.com    
ONI Medical Systems, Inc.MRI Resource Directory:
 - Manufacturers -
 
www.onicorp.com Founded in June 1997, ONI is a privately held company headquartered in Wilmington, Massachusetts. ONI is focused on addressing the new healthcare economics by delivering the next generation of MRI machines: high field, low cost dedicated purpose systems. The company's first offering was the OrthOne™. Further developements lead to the MSK Extreme™, a 1.0 Tesla dedicated purpose MR system with v-SPEC™ Technology and DICOM Conformance for extremity applications.

MRI Related Product Line:
MSK Extreme™

Contact Information
MAIL ONI, Inc.
301 Ballardvale Street,
Suite 4
Wilmington, MA 01887
USA
PHONE +1-978-658-0020
FAX +1-978-658-0898
E-MAIL info@onicorp.com
ONLINE www.onicorp.com
 •• There are 4 news about 'ONI Medical Systems, Inc.'.
MRI Resources  
Bioinformatics - Claustrophobia - Lung Imaging - Case Studies - Corporations - Liver Imaging
 
MRI Resources  
MRI Accidents - Diffusion Weighted Imaging - MR Guided Interventions - MRI Technician and Technologist Jobs - Spine MRI - Devices
 
     1 - 2 (of 2)     
Result Pages : [1]
 Random Page
 
MR-TIP     
Community   
User
Pass
Forgot your UserID/Password ?  


Most annoying at MRI :
noise 
downtimes 
service 
magnetic hazards 
updates 
cost 
administration 

Look
      Ups

Latest     
  News 


ADVERTISEMENT
ADVERTISEMENT


Magnetic Resonance - Technology Information Portal
Copyright © 2003 - 2009 Softways. All rights reserved.
Terms of Use | Privacy Policy | Advertising
 [last update: 2010-02-08 05:21:14]