Truncation ArtifactInfoSheet: - Artifacts - 
Case Studies, 
Reduction Index, 
etc.MRI Resource Directory:
 - Artifacts -
 
Quick Overview
Please note that there are different common names for this artifact.
Artifact Information
NAME
DESCRIPTION
Edge ringing, syrinx-like stripe
REASON
Sharp changes in intensity (incomplete digitization of the echo)
HELP
Take more samples
A data truncation artifact may occur when the interface between high and low signal intensities is encountered in one imaging plane. The 2D-FT techniques transform the MR signal to spatial intensity image data with frequency and phase information encoding each axis in the plane of the scan. This artifact is found in both frequency and phase axes. Artifactual ripples adjacent to edges in an image or sharp features in a spectrum, caused by omission of higher frequency terms in Fourier transformation, particularly with the use of zero filling to replace unsampled higher frequencies.
Complex shapes are specified by series of sine and cosine waves of various frequencies, phase and amplitude. Some shapes are more difficult to encode than others. The most difficult shapes to represent with Fourier series of terms are waveforms with instantaneous transitions, tissue discontinuities or edges. The low-frequency components of the series describe the overall shape of the step function. Higher frequency components are needed to describe the corners if the step function more accurately. If not enough samples are taken, these areas cannot be accurately represented. The truncation of the infinite data series results in a ringing artifact because of the inability to accurately approximate this tissue discontinuity with a shorter truncated data set. Therefore, the ringing that occurs at all tissue boundaries on MR is called truncation artifact.
mri safety guidance
Image Guidance
This problem can be easily resolved by taking more samples - a higher acquisition matrix and/or a smaller FOV. See Gibbs Artifact and Gibbs Phenomenon.
spacer
 
• Related Searches:
    • Gibbs Ringing
    • Apodization
    • Ringing Artifact Reduction
    • Undersampling
    • Filtering
 
Further Reading:
  News & More:
Magnetic Resonance Imaging (MRI)
2003   by www.hull.ac.uk    
MRI Resources 
Claustrophobia - MRI Training Courses - Databases - Cochlear Implant - Patient Information - Abdominal Imaging
 
Image Reconstruction
 
The mathematical process of converting the composite signals obtained during the data acquisition phase into an image.
spacer

• View the DATABASE results for 'Image Reconstruction' (9).Open this link in a new window

 
Further Reading:
  Basics:
MR Image Reconstruction from Raw Data
   by dukemil.egr.duke.edu    
  News & More:
Hybrid Scanner Brings Molecular Functioning To The Forefront
Tuesday, 16 June 2009   by www.sciencedaily.com    
MRI Resources 
Breast MRI - Portals - Patient Information - Resources - Education pool - Mobile MRI Rental
 
Intra Uterine PessarMRI Resource Directory:
 - Safety -
 
Most of the commonly used intrauterine contraceptive devices (IUD) do not move under the influence of the magnetic field, do not heat up during sequences usually applied for pelvic imaging, and do not produce major artifacts in vitro or in vivo.
mri safety guidance
MRI Safety Guidance
Thus, patients with either all plastic or copper IUDs can be safely imaged with magnetic resonance imaging (MRI) machines.
spacer
Searchterm 'tr' was also found in the following services: 
spacer
News  (1852)  Resources  (540)  Forum  (420)  
 
Intrinsic Efficiency
 
Efficiency characteristic of the device or material itself.
spacer
MRI Resources 
Corporations - MRI Physics - Safety Products - Online Books - MRI Technician and Technologist Career - Crystallography
 
Oral Contrast AgentsForum -
related threadsInfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
A limitation of abdominal MRI can be the assessment of malignancies by difficulties to distinguish bowel from other organs or malignant masses. The use of oral contrast agents can reduce this problem. Properties of an ideal oral contrast agent are little or no absorption by the stomach or intestines, complete excretion, no motion or susceptibility artifacts, and uniform marking of the GI tract.
Gastrointestinal MRI contrast agents are divided in materials with bright appearance or dark appearance. The choice of a negative or a positive oral contrast agent depends on the specific problem or the pulse sequence.

See also Positive Oral Contrast Agents, Negative Oral Contrast Agents, Gastrointestinal Diamagnetic Contrast Agents, Gastrointestinal Paramagnetic Contrast Agents and Gastrointestinal Superparamagnetic Contrast Agents.

See also the related poll result: 'The development of contrast agents in MRI is'
spacer

• View the DATABASE results for 'Oral Contrast Agents' (17).Open this link in a new window

 
Further Reading:
  News & More:
Usefulness of MR Imaging for Diseases of the Small Intestine: Comparison with CT
2000   by www.ncbi.nlm.nih.gov    
Nottingham scientists exploit MRI technology to assist in the treatment of IBS
Thursday, 9 January 2014   by www.news-medical.net    
MRI Resources 
IR - Process Analysis - Research Labs - Online Books - Artifacts - Equipment
 
previous      71 - 75 (of 1010)     next
Result Pages : [1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 ... ]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



MRI is trending to low field magnets :
reduced costs will lead to this change 
AI will close the gap to high field 
only in remote areas 
is only temporary 
never 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 28 April 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]