Sinerem®InfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
Sinerem® is the brand name (same as Combidex®) for an ultrasmall superparamagnetic iron oxide (USPIO) to detect metastatic disease in lymph nodes. Metastatic nodes show less uptake of this MRI contrast agent, which results in less signal decrease and allows the differentiation of normal lymph nodes from normal-sized, metastatic nodes.
Lymph node imaging with Sinerem® is performed 24 to 36 hours after slow infusion. Normal lymph nodes turn black post contrast, namely on T2* weighted images. Metastatic lymph nodes remain unchanged in signal intensity.
Indication and Diseases: Cancer, Imaging for diagnosis, Lymphatic disorders.
See Ferumoxtran, and Classifications, Characteristics, etc.

Guerbet decided in 2007 to withdraw its Marketing Authorisation Application (MAA) for Sinerem.
Drug Information and Specification
NAME OF COMPOUND
Ferumoxtran, USPIO, AMI-227
CENTRAL MOIETY
Fe3+/Fe2+
CONTRAST EFFECT
r1=25, r2=160, B0=0.47T, r1=23.3, r2=48.9, B0=0.47T
PHARMACOKINETIC
Vascular, lymph v. hepatocyte (AG-USPIO)
CONCENTRATION
DOSAGE
2.6 mg Fe/kg
PREPARATION
Suspend in an isotonic glucose solution
INDICATION
MR angiography vascular, staging of RES-directed liver diseases, lymph nodes
DEVELOPMENT STAGE
-
DISTRIBUTOR
PRESENTATION
DO NOT RELY ON THE INFORMATION PROVIDED HERE, THEY ARE
NOT A SUBSTITUTE FOR THE ACCOMPANYING PACKAGE INSERT!
spacer
 
• Share the entry 'Sinerem®':  Facebook  Twitter  LinkedIn  
 
Further Reading:
  Basics:
The demise of Combidex - Sinerem
Wednesday, 24 March 2010   by www.wellsphere.com    
  News & More:
Ultrasmall Superparamagnetic Particles of Iron Oxide-enhanced in vivo MRI of human atherosclerotic plaques.(.pdf)
MRI Resources 
Image Quality - Musculoskeletal and Joint MRI - Mobile MRI Rental - Safety Training - MRI Physics - Bioinformatics
 
Gd-DTPA-PolylysineInfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.
 
Short name: PLLGd-DTPA, generic name: (Gd-DTPA)n-polylysine, chemical compound: Gd-DTPA poly(L-lysine-Gd-diethylenetriamine-N,N,N',N'',N''-pentaacetic acid), central moiety: Gd2+, relaxivity: r1=13.1, B0=0.23T
A polymeric MRI contrast agent under development (preclin., Bayer Schering Pharma AG, Berlin, Germany) with advantages in both MRA and in the differential diagnosis of tumors, particularly in perfusion studies of the myocardium and potential in MR lung perfusion. Dozens of the relatively small molecule Gd-DTPA is bound covalently to polylysine, a large molecular weight backbone. The stable, highly water-soluble agent does not diffuse through the endothelium of the vascular system; it is subject to renal elimination.
spacer

• View the DATABASE results for 'Gd-DTPA-Polylysine' (2).Open this link in a new window

MRI Resources 
Resources - Non-English - NMR - Stimulator pool - General - Pediatric and Fetal MRI
 
Cartesian Sampling
 
Cartesian sampling is used to refer to data collection with a fixed value of the phase encoding gradient. In 2D Fourier imaging with common Cartesian sampling of k-space sensitivity encoding by means of a receiver array enables to reduce the number of Fourier encoding steps. This is achieved by increasing the distance of sampling positions in k-space while maintaining the maximum k-values.
The Cartesian coordinates are obtained from the polar coordinates by the operations
x = r sin f
y = r cos f
using the trigonometric functions sine and cosine.
spacer

• View the DATABASE results for 'Cartesian Sampling' (4).Open this link in a new window

Searchterm 'sine' was also found in the following services: 
spacer
News  (70)  Resources  (16)  Forum  (5)  
 
FerumoxtranInfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.
 
Short name: Ami 227, generic name: Ferumoxtran, (USPIO)
Ferumoxtran is a substance of the class of ultrasmall superparamagnetic iron oxide used as a lymph node specific contrast agent for MRI.
See also Combidex®, Sinerem® and Ultrasmall Superparamagnetic Iron Oxide.
Partner(s): Cytogen Corporation, National Cancer Institute. An approvable letter was received from the U.S. Food and Drug Administration for Combidex in June 2000. Advanced Magnetics, Inc. has submitted a complete response to the approvable letter received from the U.S. Food and Drug Administration, which was accepted by the FDA and assigned a user fee goal date of March 30, 2005. In Europe, a Dossier (the European equivalent of a NDA) was submitted by Advanced Magnetics' European partner, Guerbet SA, to the European Medicines Evaluations Agency in December 1999. (Sinerem® is the brand name for this USPIO in Europe manufactured by Guerbet, Combidex® by Advanced Magnetics for the U.S. market)
Advanced Magnetics, Inc. changed its name in July 2007 to AMAG Pharmaceuticals Inc.
spacer

• View the DATABASE results for 'Ferumoxtran' (3).Open this link in a new window

 
Further Reading:
  Basics:
Superparamagnetic Iron Oxide–enhanced MR Imaging of Head and Neck Lymph Nodes1
Comparison of Two Superparamagnetic Viral-Sized Iron Oxide Particles Ferumoxides and Ferumoxtran-10 with a Gadolinium Chelate in Imaging Intracranial Tumors
2002   by www.ajnr.org    
  News & More:
Optimized Labelling of Human Monocytes with Iron Oxide MR Contrast Agents
Sunday, 30 November 2003   by rsna2003.rsna.org    
SPL Medical starts clinical trial with contrast agent ferrotran
Tuesday, 11 February 2020   by www.radboudumc.nl    
SPL Medical receives approval for Clinical Trial with contrast agent Ferrotran® in 10 top radiology centers.
Friday, 15 March 2019   by ferrotran.com    
Ultrasmall Superparamagnetic Particles of Iron Oxide-enhanced in vivo MRI of human atherosclerotic plaques.(.pdf)
MRI Resources 
Shielding - Health - Image Quality - Mass Spectrometry - Shoulder MRI - Safety Training
 
GE HealthcareMRI Resource Directory:
 - Manufacturers -
 
www.gehealthcare.com GE Healthcare is the result of the merger between GE Medical and Amersham Health in Nov. 2004, after GE acquired Amersham Health for 9.5 billion in Oct. 2003. Jeffrey R. Immelt, Chairman of the Board and Chief Executive of General Electric, said, 'Amersham's diagnostic pharmaceutical and life sciences business will add new, high growth platforms to GE Medical's diagnostic imaging, services and healthcare information technology businesses'. GE Healthcare, a UK company, is a unit of General Electric (NYSE: GE). GE Healthcare is a global leader in medical imaging, diagnostic imaging contrast agents, interventional procedures, healthcare services, and information technology. For more than 100 years, health care providers have relied on GE Medical Systems, now GE Healthcare, for high quality medical technology and productivity solutions. GE Healthcare, headquartered now at formerly seat of Amersham Health in Great Britain, operates facilities around the world. Global Operations include organizations on the Americas, Europe, and Asia, including India, Japan, Korea China, Thailand and Vietnam.

MRI Scanners:

MRI Contrast Agents:
•
•
Contact Information
spacer

• View the DATABASE results for 'GE Healthcare' (23).Open this link in a new window


• View the NEWS results for 'GE Healthcare' (26).Open this link in a new window.
 
Further Reading:
  Basics:
GE Medical's new name: GE Healthcare
Friday, 6 February 2004   by milwaukee.bizjournals.com    
  News & More:
GE HealthCare introduces new MRI agent Pixxoscan
Friday, 28 April 2023   by www.medicaldevice-network.com    
GE Healthcare Names New 3.0T MRI System for Today's Healthcare Heroes
Monday, 13 December 2021   by www.itnonline.com    
GE Healthcare announces FDA approval of macrocyclic MRI contrast agent Clariscan
Monday, 4 November 2019   by www.itnonline.com    
GE Healthcare expands MRI contrast media product range in Europe with launch of macrocyclic agent ClariscanTM
Wednesday, 1 March 2017   by www.businesswire.com    
A*STAR & GE Healthcare Collaborate On Med Tech
Monday, 22 December 2014   by www.asianscientist.com    
MRI Resources 
Breast MRI - MR Guided Interventions - MRI Training Courses - Hospitals - Pediatric and Fetal MRI - IR
 
     1 - 5 (of 35)     next
Result Pages : [1]  [2 3 4 5 6 7]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



Personalized protocols (age, gender, body habitus, etc.) lead to :
more automated planning 
improved patient comfort 
better diagnostics 
optimized image quality 
nothing 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 11 May 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]