 | Info Sheets |
| | | | | | | | | | | | | | | | | | | | | | |
 | Out- side |
| | | | |
|
| | | | |
Result : Searchterm 'Signa Infinity 1.5T™ with Excite' found in 1 term [ ] and 1 definition [ ], (+ 1 Boolean[ ] results
| 1 - 3 (of 3) Result Pages : [1] | |  | | |
 |
MRI Resources |
|
| | | |  |  |  |
| Signa Infinity 1.5T™ with Excite |   |
| |
|
From GE Healthcare;
'EXCITE technology has the potential to open the door to new imaging techniques and clinical applications, leaping beyond conventional two and three-dimensional MRI to true 4D imaging that will improve the diagnosis of disease throughout the human body from head to foot.' Robert R. Edelman, M.D., Professor of Radiology at Northwestern University Medical School and Chairman, Department of Radiology, at Evanston Northwestern Healthcare.
|
|
Device Information and Specification |
| CLINICAL APPLICATION |
Whole body |
| CONFIGURATION |
Short bore |
| SURFACE COILS |
Head and body coil standard; all other coils optional; open architecture makes system compatible with a wide selection of coils |
| SPECTROSCOPY |
Optional 2D/3D brain and prostate |
| SYNCHRONIZATION |
ECG/peripheral, respiratory gating, (SmartPrep, SmartStep) |
| PULSE SEQUENCES |
Standard: SE, IR, 2D/3D GRE and SPGR, Angiography: 2D/3D TOF, 2D/3D Phase Contrast;; 2D/3D FSE, 2D/3D FGRE and FSPGR, SSFP, FLAIR, EPI, optional: 2D/3D Fiesta, FGRET, Spiral, Tensor |
| IMAGING MODES |
Localizer, single slice, multislice, volume, fast, POMP, multi slab, cine |
| TR |
1.3 to 12000 msec in increments of 1 msec |
| TE |
0.4 to 2000 msec in increments of 1 msec |
| SINGLE/MULTI SLICE |
Simultaneous scan and reconstruction;; up to 200 or 400 images per second |
| FOV |
1 cm to 48 cm continuous |
| SLICE THICKNESS |
2D 0.7 mm to 20 mm; 3D 0.1 mm to 5 mm |
| DISPLAY MATRIX |
1028 x 1024 |
| MEASURING MATRIX |
128x512 steps 32 phase encode |
| PIXEL INTENSITY |
256 gray levels |
| SPATIAL RESOLUTION |
0.08 mm; 0.02 mm optional |
| MAGNET TYPE |
Superconducting |
| BORE DIAMETER |
60 cm |
| MAGNET WEIGHT |
3863 kg |
| H*W*D |
172 x 208 x 216 cm |
| POWER REQUIREMENTS |
480 or 380/415 |
| COOLING SYSTEM TYPE |
Closed-loop water-cooled gradient |
| CRYOGEN USE, L/hr |
less than 0.03 L/hr liquid helium |
| FIELD STRENGTH |
1.5 T |
| STRENGTH |
SmartSpeed 23 mT/m, HiSpeed Plus 33 mT/m, EchoSpeed Plus 33 mT/m |
| 5-GAUSS FRINGE FIELD |
4.0 m x 2.8 m axial x radial |
| SHIMMING |
Active |
|
| |  | |
Further Reading: |
Basics:
|
|
News & More:
| | | | |
|  |  |
| GE Healthcare |  |
| |
|
GE Healthcare is the result of the merger between GE Medical and Amersham Health in Nov. 2004, after GE acquired Amersham Health for 9.5 billion in Oct. 2003. Jeffrey R. Immelt, Chairman of the Board and Chief Executive of General Electric, said, 'Amersham's diagnostic pharmaceutical and life sciences business will add new, high growth platforms to GE Medical's diagnostic imaging, services and healthcare information technology businesses'. GE Healthcare, a UK company, is a unit of General Electric (NYSE: GE). GE Healthcare is a global leader in medical imaging, diagnostic imaging contrast agents, interventional procedures, healthcare services, and information technology.
For more than 100 years, health care providers have relied on GE Medical Systems, now GE Healthcare, for high quality medical technology and productivity solutions.
GE Healthcare, headquartered now at formerly seat of Amersham Health in Great Britain, operates facilities around the world. Global Operations include organizations on the Americas, Europe, and Asia, including India, Japan, Korea China, Thailand and Vietnam.
|
MRI Related Product Lines:
Devices:
| |
|
Contrast Agents:
| |
|
|
| |  | |
Further Reading: |
Basics:
|
|
News & More:
| | | | | | •• There are 26 news about 'GE Healthcare'. | |
|  |
 |
MRI Resources |
|
| | | |  |  |
|
 |  |
| Signa Infinity 1.5T™ TwinSpeed with Excite |   |
| |
|
From GE Healthcare;
three dedicated MRI systems - a neuro imager, a cardiovascular system, and a whole body scanner - all in one system.
|
|
Device Information and Specification |
| CLINICAL APPLICATION |
Whole body |
| CONFIGURATION |
Short bore |
| SURFACE COILS |
Head and body coil standard; all other coils optional; open architecture makes system compatible with a wide selection of coils |
| SPECTROSCOPY |
Optional 2D/3D brain and prostate |
| SYNCHRONIZATION |
ECG/peripheral, respiratory gating |
| PULSE SEQUENCES |
Standard: SE, IR, 2D/3D GRE and SPGR, Angiography: 2D/3D TOF, 2D/3D Phase Contrast;; 2D/3D FSE, 2D/3D FGRE and FSPGR, SSFP, FLAIR, EPI, optional: 2D/3D Fiesta, FGRET, Spiral, Tensor |
| IMAGING MODES |
Localizer, single slice, multislice, volume, fast, POMP, multi slab, cine |
| TR |
1.2 to 12000 msec in increments of 1 msec |
| TE |
0.4 to 2000 msec in increments of 1 msec |
| SINGLE/MULTI SLICE |
Simultaneous scan and reconstruction;; up to 200 or 400 images per second |
| FOV |
1 cm to 48 cm continuous |
| SLICE THICKNESS |
2D 0.7 mm to 20 mm; 3D 0.1 mm to 5 mm |
| DISPLAY MATRIX |
1280 x 1024 |
| MEASURING MATRIX |
128x512 steps 32 phase encode |
| PIXEL INTENSITY |
256 gray levels |
| SPATIAL RESOLUTION |
0.02mm |
| MAGNET TYPE |
Superconducting |
BORE DIAMETER or W x H |
60 cm |
| MAGNET WEIGHT |
3863 kg |
| H*W*D |
172 x 208 x 216 cm |
| POWER REQUIREMENTS |
480 or 380/415 |
| COOLING SYSTEM TYPE |
Closed-loop water-cooled gradient |
| CRYOGEN USE |
Less than 0.03 L/hr liquid He |
| FIELD STRENGTH |
1.5 T |
| STRENGTH |
Zoom 40 mT/m, whole body 23 mT/m |
| 5-GAUSS FRINGE FIELD |
4.0 m x 2.8 m axial x radial |
| SHIMMING |
Active |
|
| |  | |
Further Reading: |
Basics:
|
|
News & More:
| | | |
|  |
|
 |
MRI Resources |
|