Magnetic Resonance - Technology Information Portal Friday, 10 September 2010••
Info
  Sheets


Out-
      side
 



 
 'Signa Infinity 1.5T™ with Excite' 
SEARCH FOR    
 
  2 3 5 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Result : Searchterm 'Signa Infinity 1.5T™ with Excite' found in 1 term [] and 1 definition [], (+ 1 Boolean[] results
1 - 3 (of 3)     
Result Pages : [1]
 bottom
MRI Resources  
Software - Claustrophobia - Societies - Mobile MRI Rental - Diffusion Weighted Imaging - Examinations
 
Signa Infinity 1.5T™ with ExciteInfoSheet: - Devices -
Intro, 
Types of Magnets, 
Overview, 
etc.MRI Resource Directory:
 - Devices -
 
From GE Healthcare;
www.gehealthcare.com/usen/mr/s_excite15/index.html 'EXCITE technology has the potential to open the door to new imaging techniques and clinical applications, leaping beyond conventional two and three-dimensional MRI to true 4D imaging that will improve the diagnosis of disease throughout the human body from head to foot.' Robert R. Edelman, M.D., Professor of Radiology at Northwestern University Medical School and Chairman, Department of Radiology, at Evanston Northwestern Healthcare.

Device Information and Specification
CLINICAL APPLICATION Whole body
CONFIGURATION Short bore
SURFACE COILS Head and body coil standard; all other coils optional; open architecture makes system compatible with a wide selection of coils
SPECTROSCOPY Optional 2D/3D brain and prostate
SYNCHRONIZATION ECG/peripheral, respiratory gating, (SmartPrep, SmartStep)
PULSE SEQUENCES Standard: SE, IR, 2D/3D GRE and SPGR, Angiography: 2D/3D TOF, 2D/3D Phase Contrast;; 2D/3D FSE, 2D/3D FGRE and FSPGR, SSFP, FLAIR, EPI, optional: 2D/3D Fiesta, FGRET, Spiral, Tensor
IMAGING MODES Localizer, single slice, multislice, volume, fast, POMP, multi slab, cine
TR 1.3 to 12000 msec in increments of 1 msec
TE 0.4 to 2000 msec in increments of 1 msec
SINGLE/MULTI SLICE Simultaneous scan and reconstruction;; up to 200 or 400 images per second
FOV 1 cm to 48 cm continuous
SLICE THICKNESS 2D 0.7 mm to 20 mm; 3D 0.1 mm to 5 mm
DISPLAY MATRIX 1028 x 1024
MEASURING MATRIX 128x512 steps 32 phase encode
PIXEL INTENSITY 256 gray levels
SPATIAL RESOLUTION 0.08 mm; 0.02 mm optional
MAGNET TYPE Superconducting
BORE DIAMETER 60 cm
MAGNET WEIGHT 3863 kg
H*W*D 172 x 208 x 216 cm
POWER REQUIREMENTS 480 or 380/415
COOLING SYSTEM TYPE Closed-loop water-cooled gradient
CRYOGEN USE, L/hr less than 0.03 L/hr liquid helium
FIELD STRENGTH 1.5 T
STRENGTH SmartSpeed 23 mT/m, HiSpeed Plus 33 mT/m, EchoSpeed Plus 33 mT/m
5-GAUSS FRINGE FIELD 4.0 m x 2.8 m axial x radial
SHIMMING Active
spacer
Further Reading:
  Basics:
Technology for Signa EXCITE HD 1.5T and 3.0TOpen this link in a new window
Friday, 11 February 2005   by www.gehealthcare.com    
Technology for Signa EXCITE HD 1.5T and 3.0T. The power of HD technology reaps meaningful rewards in my clinical practices.Open this link in a new window
Friday, 11 February 2005   by www.gehealthcare.com    
  News & More:
New Applications that flow from and depend on EXCITEOpen this link in a new window
Friday, 11 February 2005   by www.gehealthcare.com    
GE HealthcareMRI Resource Directory:
 - Manufacturers -
 
www.gehealthcare.com GE Healthcare is the result of the merger between GE Medical and Amersham Health in Nov. 2004, after GE acquired Amersham Health for 9.5 billion in Oct. 2003. Jeffrey R. Immelt, Chairman of the Board and Chief Executive of General Electric, said, 'Amersham's diagnostic pharmaceutical and life sciences business will add new, high growth platforms to GE Medical's diagnostic imaging, services and healthcare information technology businesses'. GE Healthcare, a UK company, is a unit of General Electric (NYSE: GE). GE Healthcare is a global leader in medical imaging, diagnostic imaging contrast agents, interventional procedures, healthcare services, and information technology. For more than 100 years, health care providers have relied on GE Medical Systems, now GE Healthcare, for high quality medical technology and productivity solutions. GE Healthcare, headquartered now at formerly seat of Amersham Health in Great Britain, operates facilities around the world. Global Operations include organizations on the Americas, Europe, and Asia, including India, Japan, Korea China, Thailand and Vietnam.

MRI Related Product Lines:

Devices:
Signa HDx 3.0T
Signa HDx 1.5T
Signa HDe 1.5T
Signa 3.0T™
Signa Infinity 1.5T™ with Excite

Signa Infinity 1.5T™ TwinSpeed with Excite

Signa OpenSpeed™
Signa Ovation™
Signa Profile™

Older

SIGNA SP 0.5T™ Open Configuration
Signa Infinity 1.0T™

Contrast Agents:
Product Information
TRADE NAME
(LOCAL DISTRIBUTION)
FOR SALE FOR SALE /
DEVELOPMENT
DEVELOPMENT
Omniscan®
Teslascan®
Clariscan™


Contact Information
ONLINE www.gehealthcare.com
CONTACT INFO PAGE www.gehealthcare.com/contact
spacer
Further Reading:
  Basics:
GE Medical's new name: GE HealthcareOpen this link in a new window
Friday, 6 February 2004   by milwaukee.bizjournals.com    
  News & More:
MR Surgical Suite, Improving surgical procedure quality Open this link in a new window
Friday, 11 February 2005   by www.gehealthcare.com    
RSNA update on new MRI technology(.pdf)Open this link in a new window
February 2006   by www.magnet-mri.org    
MR Guided Focused Ultrasound, ExAblate 2000 - Non-invasive MR guided Focused Ultrasound Surgery for Uterine FibroidsOpen this link in a new window
Friday, 11 February 2005   by www.gehealthcare.com    
MRI's inside storyOpen this link in a new window
Thursday, 4 December 2003   by www.economist.com    
GE Healthcare, Insightec Sign Worldwide Sales and Marketing Agreement for ExAblate 2000 Focused Ultrasound System Non-Invasively Treats Uterine Fibroids; System Powered by GE Healthcare EquipmentOpen this link in a new window
Wednesday, 17 August 2005   by www.gehealthcare.com    
 •• There are 26 news about 'GE Healthcare'.
MRI Resources  
Safety Products - Devices - IR - Chemistry - MRI Training Courses - Liver Imaging
 
Signa Infinity 1.5T™ TwinSpeed with ExciteInfoSheet: - Devices -
Intro, 
Types of Magnets, 
Overview, 
etc.MRI Resource Directory:
 - Devices -
 
From GE Healthcare;
www.gehealthcare.com/usen/mr/s_excite15/index.html three dedicated MRI systems - a neuro imager, a cardiovascular system, and a whole body scanner - all in one system.
Device Information and Specification
CLINICAL APPLICATION Whole body
CONFIGURATION Short bore
SURFACE COILS Head and body coil standard; all other coils optional; open architecture makes system compatible with a wide selection of coils
SPECTROSCOPY Optional 2D/3D brain and prostate
SYNCHRONIZATION ECG/peripheral, respiratory gating
PULSE SEQUENCES Standard: SE, IR, 2D/3D GRE and SPGR, Angiography: 2D/3D TOF, 2D/3D Phase Contrast;; 2D/3D FSE, 2D/3D FGRE and FSPGR, SSFP, FLAIR, EPI, optional: 2D/3D Fiesta, FGRET, Spiral, Tensor
IMAGING MODES Localizer, single slice, multislice, volume, fast, POMP, multi slab, cine
TR 1.2 to 12000 msec in increments of 1 msec
TE 0.4 to 2000 msec in increments of 1 msec
SINGLE/MULTI SLICE Simultaneous scan and reconstruction;; up to 200 or 400 images per second
FOV 1 cm to 48 cm continuous
SLICE THICKNESS 2D 0.7 mm to 20 mm; 3D 0.1 mm to 5 mm
DISPLAY MATRIX 1280 x 1024
MEASURING MATRIX 128x512 steps 32 phase encode
PIXEL INTENSITY 256 gray levels
SPATIAL RESOLUTION 0.02mm
MAGNET TYPE Superconducting
BORE DIAMETER
or W x H
60 cm
MAGNET WEIGHT 3863 kg
H*W*D 172 x 208 x 216 cm
POWER REQUIREMENTS 480 or 380/415
COOLING SYSTEM TYPE Closed-loop water-cooled gradient
CRYOGEN USE Less than 0.03 L/hr liquid He
FIELD STRENGTH 1.5 T
STRENGTH Zoom 40 mT/m, whole body 23 mT/m
5-GAUSS FRINGE FIELD 4.0 m x 2.8 m axial x radial
SHIMMING Active
spacer
Further Reading:
  Basics:
Technology for Signa EXCITE HD 1.5T and 3.0TOpen this link in a new window
Friday, 11 February 2005   by www.gehealthcare.com    
Technology for Signa EXCITE HD 1.5T and 3.0T. The power of HD technology reaps meaningful rewards in my clinical practices.Open this link in a new window
Friday, 11 February 2005   by www.gehealthcare.com    
  News & More:
Twin Gradient Technology - Potential Advantages For Diffusion Weighted MRI(.pdf)Open this link in a new window
   by www.paulrharvey.co.uk    
MRI Resources  
Veterinary MRI - Movies - Breast Implant - Stent - MRI Accidents - Pathology
 
     1 - 3 (of 3)     
Result Pages : [1]
 Random Page
 
MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?  



Would like to get waked up on holidays by :
FLAIR 
spin echo 
gradient echo 
diffusion 
EPI 
NO! 

Look
      Ups





Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • US-TIP • The-Medical-Market
Copyright © 2003 - 2010 SoftWays. All rights reserved.
Terms of Use | Privacy Policy | Advertising
 [last update: 2010-09-06 01:57:00]