Magnetic Resonance - Technology Information Portal Welcome to MRI Technology
Info
  Sheets

Out-
      side
 



 
 'My' 
SEARCH FOR    
 
  2 3 5 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Result : Searchterm 'My' found in 3 terms [] and 45 definitions []
previous     26 - 30 (of 48)     next
Result Pages : [1]  [2 3 4 5 6 7 8 9 10]
Searchterm 'My' was also found in the following services: 
spacer
News  (92)  Resources  (45)  Forum  (146)  
 
Diffusion Weighted ImagingForum -
related threadsMRI Resource Directory:
 - Diffusion Weighted Imaging -
 
(DWI) Magnetic resonance imaging is sensitive to diffusion, because the diffusion of water molecules along a field gradient reduces the MR signal. In areas of lower diffusion the signal loss is less intense and the display from this areas is brighter. The use of a bipolar gradient pulse and suitable pulse sequences permits the acquisition of diffusion weighted images (images in which areas of rapid proton diffusion can be distinguished from areas with slow diffusion).
Based on echo planar imaging, multislice DWI is today a standard for imaging brain infarction. With enhanced gradients, the whole brain can be scanned within seconds. The degree of diffusion weighting correlates with the strength of the diffusion gradients, characterized by the b-value, which is a function of the gradient related parameters: strength, duration, and the period between diffusion gradients.
Certain illnesses show restrictions of diffusion, for example demyelinization and cytotoxic edema. Areas of cerebral infarction have decreased apparent diffusion, which results in increased signal intensity on diffusion weighted MRI scans. DWI has been demonstrated to be more sensitive for the early detection of stroke than standard pulse sequences and is closely related to temperature mapping.
DWIBS is a new diffusion weighted imaging technique for the whole body that produces PET-like images. The DWIBS sequence has been developed with the aim to detect lymph nodes and to differentiate normal and hyperplastic from metastatic lymph nodes. This may be possible caused by alterations in microcirculation and water diffusivity within cancer metastases in lymph nodes.

See also Diffusion Weighted Sequence, Perfusion Imaging, ADC Map, Apparent Diffusion Coefficient, and Diffusion Tensor Imaging.
spacer
 
• Related Searches:
    • Eigenvalues
    • Molecule
    • Signal Intensity
    • Diffusion Tensor Tractography
    • Diffusion Weighted Whole Body Imaging
 
Further Reading:
  Basics:
EVALUATION OF HUMAN STROKE BY MR IMAGING
2000
Novel MRI Technique Could Reduce Breast Biopsies, University of Washington Study
Tuesday, 2 October 2012   by www.eurekalert.org    
Quantitative Apparent Diffusion Coefficient Measurements Obtained by 3-Tesla MRI Are Correlated with Biomarkers of Bladder Cancer Proliferative Activity
   by www.plosone.org    
  News & More:
Stability and repeatability of diffusion-weighted imaging (DWI) of normal pancreas on 5.0 Tesla magnetic resonance imaging (MRI)
Monday, 24 July 2023   by www.nature.com    
MRI innovation makes cancerous tissue light up and easier to see
Monday, 21 March 2022   by www.sciencedaily.com    
Diffusion MRI and machine learning models classify childhood brain tumours
Saturday, 6 March 2021   by physicsworld.com    
Diffusion-weighted MRI in Advanced Epithelial Ovarian Cancer: Apparent Diffusion Coefficient as a Response Marker
Tuesday, 1 October 2019   by pubs.rsna.org    
Novel Imaging Technique Improves Prostate Cancer Detection
Tuesday, 6 January 2015   by health.ucsd.edu    
High-b-value Diffusion-weighted MR Imaging of Suspected Brain Infarction
2000   by www.ajnr.org    
Searchterm 'My' was also found in the following services: 
spacer
Radiology  (20) Open this link in a new windowUltrasound  (38) Open this link in a new window
FerrioxamineInfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.
 
Ferrioxamines are potential iron oxide-based intravascular contrast agents. Ferrioxamine methanesulfonate, ferrioxamine-B, and hydroxyethyl-starch-ferrioxamine have been tested as MRI contrast agents, partly in clinical trials.
Ferrioxamine methanesulfonate was tested as a paramagnetic agent for the imaging of the kidney and the urogenital system. Hydroxyethyl-starch-ferrioxamine has the potential to provide information regarding myocardial vascular flow and ferrioxamine-B derivatives may be used as hepatobiliary contrast agents.

See also Superparamagnetic Iron Oxide, Hepatobiliary Contrast Agents.
spacer

• View the DATABASE results for 'Ferrioxamine' (2).Open this link in a new window

MRI Resources 
Functional MRI - Non-English - Breast Implant - Breast MRI - Lung Imaging - Shoulder MRI
 
Flow Sensitive Alternating Inversion RecoveryInfoSheet: - Sequences - 
Intro, 
Overview, 
Types of, 
etc.
 
(FAIR) In this sequence 2 inversion recovery images are acquired, one with a nonselective and the other with a slice selective inversion pulse. The z-magnetization in the first sequence is independent of flow. Inflowing spins give z-magnetization from second pulse. A major signal loss in FAIR is the T1 relaxation of tagged blood in transit to the imaging slice. Sharper edges of the inversion pulse give narrow spacing between the inversion edge and the 1st slice because reduced transit time gives lower T1 relaxation induced signal loss. The difference of the images in a consequence contains information proportional to flow (blood partition coefficient). Standard adiabatic inversion RF pulse does not have good slice-profile, because of power/SAR limitation. A c-shaped frequency offset corrected inversion (FOCI) RF pulse can help to increase the signal.
Perfusion imaging, e.g. myocardial, using tissue water as endogenous contrast is suggested.
spacer
Searchterm 'My' was also found in the following services: 
spacer
News  (92)  Resources  (45)  Forum  (146)  
 
GadophrinInfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.
 
Short name: Gd-DTPA mesoporphyrin, generic name: gadophrin, central moiety: Gd2+
Gadophrin is a substance under development (Bayer Schering Pharma AG) as a positive enhancing myocardium- and necrosis- targeted MRI contrast agent.

See also Metalloporphyrins and Necrosis Avid Contrast Agent.
spacer

• View the DATABASE results for 'Gadophrin' (5).Open this link in a new window

Searchterm 'My' was also found in the following services: 
spacer
Radiology  (20) Open this link in a new windowUltrasound  (38) Open this link in a new window
Gd-DTPA MesoporphyrinInfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.
 
Short name: Gd-DTPA mesoporphyrin, generic name: gadophrin, central moiety: Gd2+
Gd-DTPA mesoporphyrin is a substance under development (Bayer Schering Pharma AG) as a positive enhancing myocardium- and necrosis- targeted MRI contrast agent.

See also Metalloporphyrins and Necrosis Avid Contrast Agent.
spacer

• View the DATABASE results for 'Gd-DTPA Mesoporphyrin' (2).Open this link in a new window

MRI Resources 
Breast Implant - Case Studies - Absorption and Emission - Nerve Stimulator - Service and Support - Pathology
 
previous      26 - 30 (of 48)     next
Result Pages : [1]  [2 3 4 5 6 7 8 9 10]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



MRI is trending to low field magnets :
reduced costs will lead to this change 
AI will close the gap to high field 
only in remote areas 
is only temporary 
never 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 2 May 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]