Result : Searchterm 'Contrast Agent' found in 18 terms [] and 188 definitions []
previous     91 - 95 (of 206)     next
Result Pages : [1 2 3 4]  [5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 ... ]
Searchterm 'Contrast Agent' was also found in the following services: 
spacer
News  (147)  Resources  (12)  Forum  (13)  
 
Molecular Imaging
 
Molecular Imaging is a new diagnostic discipline to visualize biological processes.
Molecular magnetic resonance imaging (mMRI) offers the potential to image tissues at the cellular and subcellular level. Targeted MR contrast agents enhance the diagnostic specificity and range of molecular magnetic resonance imaging.
Other modalities that can be used for noninvasive molecular imaging:
•
Ultrasound;
•
optical imaging;
•
positron emission tomography (PET);
•
single photon emission computed tomography (SPECT).


See also Nanoparticle, Monocrystalline Iron Oxide Nanoparticle, Polycrystalline Iron Oxide Nanoparticles, Liposomes, Monoclonal Antibodies, Bimodal Imaging, Tumor Specific Agents, and Intracellular Contrast Agents.
spacer

• View the NEWS results for 'Molecular Imaging' (28).Open this link in a new window.
 
Further Reading:
  Basics:
Multimodal Nanoparticles for Quantitative Imaging(.pdf)
Tuesday, 13 December 2011   by alexandria.tue.nl    
Molecular Magnetic Resonance Imaging(.pdf)
2005   by www.medical.siemens.com    
  News & More:
Smarter MRI diagnosis with nano MRI lamp
Monday, 6 February 2017   by www.eurekalert.org    
Molecular MRI technique gives early indication of cancer treatment effectiveness
Monday, 11 April 2016   by www.healthimaging.com    
Molecular imaging and radiochemistry: the importance of instrumentation. An interview with Professor Bjorn Wangler
Thursday, 4 February 2016   by www.news-medical.net    
Positron Emission Tomographic Imaging in Stroke
Monday, 28 December 2015   by www.ncbi.nlm.nih.gov    
Potential and Limitations of Oxygen-17 MR Perfusion Measurements
Monday, 1 March 2004   by www.case.edu    
MRI Resources 
Universities - Spine MRI - Hospitals - Shielding - Knee MRI - Veterinary MRI
 
MultiHance®InfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
MultiHance® is a paramagnetic contrast agent for use in diagnostic magnetic resonance imaging (MRI) of the liver and central nervous system. MultiHance® is a small molecular weight chelate, which tightly binds the Gd atom. The substance is excreted partly by the kidneys, partly by the biliary system, which is especially unique.
MultiHance® is indicated, for the detection of focal liver lesions in patients with known or suspected primary liver cancer (e.g. hepatocellular carcinoma) or metastatic disease.
MultiHance® is also indicated in brain MRI and spine MRI where it improves the detection of lesions and provides diagnostic information additional to that obtained with unenhanced MRI.
Gd-BOPTA-enhanced MRA can provide superior vascular signal intensity and SNR, as compared with Gd-DTPA, due to its higher relaxivity, even at lower doses.
1 ml of solution MultiHance® contains: (0.5M) gadobenate dimeglumine 529 mg = gadobenic acid 334 mg + meglumine 195 mg. Viscosity at 37°C: 5.3 mPa

WARNING: NEPHROGENIC SYSTEMIC FIBROSIS Gadolinium-based contrast agents increase the risk for nephrogenic systemic fibrosis (NSF) in patients with acute or chronic severe renal insufficiency (glomerular filtration rate less than 30 mL/min/1.73m2), or acute renal insufficiency of any severity due to the hepato-renal syndrome or in the perioperative liver transplantation period.
Drug Information and Specification
NAME OF COMPOUND
Gadobenate dimeglumine, Gd-BOPTA, E7155
DEVELOPER
CENTRAL MOIETY
Gd2+
CONTRAST EFFECT
T1, predominantly positive enhancement
r1=9.7, r2=12.5, B0=0.5 T
PHARMACOKINETIC
Extracellular, hepatobiliary
1970 mosm/kg
CONCENTRATION
334 mg/ml
DOSAGE
0.05 mmol/kg for Liver MRI
0.1 mmol/kg for CNS MRI
PREPARATION
Solution for injection
INDICATION
CNS, Liver MRI
DEVELOPMENT STAGE
For sale
DISTRIBUTOR
See below
PRESENTATION
Vials of 5, 10, 15 and 20 mL, 50 and 100 mL Multipacks (Pharmacy Bulk Package)
DO NOT RELY ON THE INFORMATION PROVIDED HERE, THEY ARE
NOT A SUBSTITUTE FOR THE ACCOMPANYING PACKAGE INSERT!
Distribution Information
TERRITORY
TRADE NAME
DEVELOPMENT
STAGE
DISTRIBUTOR
EU
MultiHance®
for sale
USA
MultiHance®
for sale
Australia
MultiHance®
for sale
spacer

• View the DATABASE results for 'MultiHance®' (9).Open this link in a new window


• View the NEWS results for 'MultiHance®' (1).Open this link in a new window.
 
Further Reading:
  Basics:
Important Drug Warning for Gadolinium-Based Contrast Agents
Wednesday, 12 September 2007   by www.ismrm.org    
MultiHance Package Insert(.pdf)
   by www.fda.gov    
  News & More:
FDA Expands Pediatric Age Range for MultiHance Contrast Agent
Tuesday, 30 January 2018   by www.empr.com    
MAGNETIC RESONANCE IMAGING OF FOCAL LIVER LESIONS(.pdf)
2002
BRACCO DIAGNOSTICS' MULTIHANCE EARNS FDA APPROVAL
Wednesday, 24 November 2004   by salesandmarketingnetwork.com    
MRI Resources 
Knee MRI - Artifacts - Societies - Mobile MRI - Crystallography - Jobs
 
Myocardial Late Enhancement
 
(LE) Myocardial late enhancement in contrast enhanced cardiac MRI has the ability to precisely delineate myocardial scar associated with coronary artery disease. Viability imaging implies evaluating infarcted myocardium to see whether there is enough viable tissue available for revascularization. The reversal of myocardial dysfunction is particularly relevant in patients with depressed ventricular function because revascularization improves long-term survival. In comparison to SPECT and PET imaging, myocardial late enhancement MRI demonstrates areas of delayed enhancement exactly in correlation with the infarcted region.
Viability on cardiac MRI (CMR) is based on the fact that all infarcts enhance vividly 10-15 minutes after the administration of intravenous paramagnetic contrast agents. This enhancement represents the accumulation of gadolinium in the extracellular space, due to the loss of membrane integrity in the infarcted tissue. This phenomenon of delayed hyperenhancement has been proven to correlate with the actual extent of the infarct.
MRI myocardial late enhancement can quantify the size, location and transmural extent of the infarct. If the transmural extent of the infarct (region of enhancement on MRI) is less than 50% of the wall thickness, there will be improved contractility in that segment following revascularization. In areas of hypokinesia, if there is a rim of "black" or non-infarcted myocardium that is not contracting well, it indicates the presence of hibernating myocardium, which is likely to improve after revascularization of the artery supplying that particular territory.
The total duration of a myocardial late enhancement MR imaging protocol for viability is approximately 30 minutes, including scout images, first-pass images, cine images in two planes, and delayed myocardial enhancement images. In order to assess viable myocardium, the gadolinium contrast agent is injected at a dose of 0.15 to 0.2 mmol/kg. After about 10 minutes, short axis and long axis views (see cardiac axes) of the heart are obtained using an inversion prepared ECG gated gradient echo sequence. The inversion pulse is adjusted to suppress normal myocardium. Areas of nonviable myocardium retain extremely high signal intensity, black areas show normal tissue.

For Ultrasound Imaging (USI) see Myocardial Contrast Echocardiography at Medical-Ultrasound-Imaging.com.
spacer

• View the DATABASE results for 'Myocardial Late Enhancement' (6).Open this link in a new window

 
Further Reading:
  Basics:
A Guide To Cardiac Imaging
   by www.simplyphysics.com    
  News & More:
Prediction of Myocardial Viability by MRI
1999   by circ.ahajournals.org    
Geron Demonstrates hESC-derived cardiomyocytes improve heart function after myocardial infarction
Monday, 27 August 2007   by www.brightsurf.com    
Searchterm 'Contrast Agent' was also found in the following services: 
spacer
News  (147)  Resources  (12)  Forum  (13)  
 
NC100150 InjectionInfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
Short name: NC100150, PEG-feron, generic name: Feruglose, preliminary trade name: Clariscanâ„¢
NC100150 injection is the code name for an USPIO (ultrasmall superparamagnetic iron oxide) MRI contrast agent under development. Microvessel permeability depends on functional and morphologic characteristics of cancer vessels and on physicochemical properties of the injected contrast medium molecule.
USPIO particles have a favorable pharmacological and tolerance profile and are being tested clinically of the potential for the quantitative characterization of tumor microvasculature and specifically for measures of the microvessel permeability. Iron-based products take advantage of their large molecular size, which prevents diffusion into body tissues. These agents are disposed of by the liver and spleen as particulate matter.
NC100150 Injection (Nycomed Amersham, Amersham Health ) consists of USPIO particles that are composed of single crystals (4- to 7-nm diameter) and stabilized with a carbohydrate polyethylene glycol (PEG) coat. The iron oxide particles have to be suspended in an isotonic glucose solution. The final diameter of an USPIO particle is approximately 20 nm. Blood pool half-life is more than two hours in humans; the particles are taken up by the mononuclear phagocyte system and distributed mainly to the liver and spleen.
NC100150 would compete with the contrast agents Ferumoxytol from AMAG Pharmaceuticals, Inc. and Vasovistâ„¢ from EPIX Pharmaceuticals, Inc., but at this time the development of NC100150 Injection/Clariscan™ is discontinued.
spacer

• View the DATABASE results for 'NC100150 Injection' (5).Open this link in a new window


• View the NEWS results for 'NC100150 Injection' (2).Open this link in a new window.
MRI Resources 
Quality Advice - Anatomy - MRI Training Courses - Pathology - Coils - Shielding
 
Omniscan®InfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
Omniscan® is a nonionic chelate complex with low osmolality used as a paramagnetic MRI contrast agent. The efficacy of Omniscan® is similar to that of Gd-DTPA. Omniscan® is given intravenously to enhance images of intracranial and spinal lesions where there is abnormal vascularity or an abnormal blood brain barrier. The complex does not cross an intact blood brain barrier so Omniscan® only accumulates in lesions such as neoplasm's and abscesses.

WARNING: NEPHROGENIC SYSTEMIC FIBROSIS Gadolinium-based contrast agents increase the risk for nephrogenic systemic fibrosis (NSF) in patients with acute or chronic severe renal insufficiency (glomerular filtration rate less than 30 mL/min/1.73m2), or acute renal insufficiency of any severity due to the hepato-renal syndrome or in the perioperative liver transplantation period.

See also Gadodiamide, and Classifications, Characteristics, etc.
Drug Information and Specification
NAME OF COMPOUND
Gadodiamide, Gd-DTPA-BMA
CENTRAL MOIETY
Gd2+
CONTRAST EFFECT
T1, Predominantly positive enhancement
r1=3.9, r2=4.3, B0=1.0T
PHARMACOKINETIC
Intravascular, extracellular, renal excretion
798 mosm/kgH2O
CONCENTRATION
287 mg/mL,0.5 mol/L
DOSAGE
0.1-0.2 mmol/kg / 0.2-0.4 ml/kg
PREPARATION
Finished product
INDICATION
Neuro/whole body
DEVELOPMENT STAGE
For sale
DISTRIBUTOR
See below
PRESENTATION
Vials of 10 mL, 15 mL and 20 mL
DO NOT RELY ON THE INFORMATION PROVIDED HERE, THEY ARE
NOT A SUBSTITUTE FOR THE ACCOMPANYING PACKAGE INSERT!
Distribution Information
TERRITORY
TRADE NAME
DEVELOPMENT
STAGE
DISTRIBUTOR
USA
Omniscan®
for sale
EU
Omniscan®
suspended
Australia
Omniscan®
for sale
spacer

• View the DATABASE results for 'Omniscan®' (7).Open this link in a new window

 
Further Reading:
  Basics:
Important Drug Warning for Gadolinium-Based Contrast Agents
Wednesday, 12 September 2007   by www.ismrm.org    
Omniscan Pharmacokinetics
  News & More:
Gadolinium-containing contrast agents: removal of Omniscan and iv Magnevist, restrictions to the use of other linear agents
Friday, 5 January 2018   by www.gov.uk    
Spurious Hypocalcemia After Omniscan- or OptiMARK-Enhanced Magnetic Resonance Imaging: An Algorithm for Minimizing a False-Positive Laboratory Value
October 2004   by www.findarticles.com    
MRI Resources 
NMR - Contrast Enhanced MRI - Crystallography - Shielding - MRI Physics - Anatomy
 
previous      91 - 95 (of 206)     next
Result Pages : [1 2 3 4]  [5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 ... ]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



How AI will impact MRI :
only diagnostics 
saving time 
reducing cost 
makes planning obsolete 
reduce human knowledge 
not at all 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 29 April 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]