 - MR Guided Interventions -
 
Possible MR guided interventions are breast MRI, liver and bone biopsies. Open MRI is advantageous to guide interventional procedures because this type of MRI scanner provides a better patient access.
Before the MRI guided biopsy is started, all the necessary precautions ensuring normal sterile and safe conditions for an intervention have to be performed. This includes the special safety issues concerning MRI surroundings and special equipment, like non-magnetic biopsy needles, localization tools (e.g. wires to mark lesions prior to surgery with breast MRI guidance) etc.

See also 5 Gauss Line, Contraindications, Low Field MRI, MR Compatibility, Magnetic Resonance Guided Focused Ultrasound and Computer Aided Detection.
spacer
 
Further Reading:
  Basics:
NeuroArm Robot Promises to Revolutionise MRI-guided Neurosurgery
Wednesday, 7 November 2007   by www.medgadget.com    
Magnetic resonance imaging guided musculoskeletal interventions
at 0.23T
2002
Physics of MRI Safety
   by www.aapm.org    
  News & More:
AI analysis finds younger AFib patients benefit from MRI-guided ablation treatments
Friday, 25 August 2023   by www.eurekalert.org    
Theranostic nano-platform for MRI-guided synergistic therapy against breast cancer
Monday, 26 September 2022   by phys.org    
Magnetic seeds used to heat and kill cancer
Tuesday, 1 February 2022   by www.sciencedaily.com    
What is the effect of MRI with targeted biopsies on the rate of patients discontinuing active surveillance? A reflection of the use of MRI in the PRIAS study
Thursday, 8 April 2021   by www.docwirenews.com    
Modeling of Active Shimming of Metallic Needles for Interventional MRI
Monday, 29 June 2020   by pubmed.ncbi.nlm.nih.gov    
Magnetic Resonance Imaging Guided Confirmatory Biopsy for Initiating Active Surveillance of Prostate Cancer
Wednesday, 11 September 2019   by jamanetwork.com    
FDA clears ViewRay's next-gen, MRI-guided radiation therapy device
Tuesday, 28 February 2017   by www.fiercebiotech.com    
Siemens, U. of Twente Biopsy Robot Promises Greater Precision, Less Cost
Friday, 22 January 2016   by www.meddeviceonline.com    
Magnetic resonance-guided motorized transcranial ultrasound system for blood-brain barrier permeabilization along arbitrary trajectories in rodents
Thursday, 24 December 2015   by www.ncbi.nlm.nih.gov    
New MRI-Guided Catheter Shows Major Potential for Stroke Treatment
Tuesday, 29 December 2015   by www.radiology.ucsf.edu    
Polish study on MRI-ultrasound for targeted prostate biopsy wins CEM award
Tuesday, 12 November 2013   by medicalxpress.com    
C4 Imaging Announces FDA 510(k) Clearance of its Positive-Signal MRI Marker - Sirius™
Friday, 6 December 2013   by www.digitaljournal.com    
MRI Resources 
MRI Reimbursement - Jobs pool - Shoulder MRI - Liver Imaging - Databases - Distributors
 
Mallinckrodt, Inc.MRI Resource Directory:
 - Manufacturers -
 
www.mallinckrodt.com Mallinckrodt, a Tyco Healthcare company makes and distributes products for respiratory care; bulk and dosage pharmaceuticals, primarily for pain relief and addiction therapy; and imaging agents for magnetic resonance, ultrasound, X-ray, and nuclear medicine applications. With worldwide manufacturing and distribution facilities, as well as worldwide sales offices, Mallinckrodt sells its products worldwide.
GastroMARK® is marketed in the United States by Mallinckrodt, Inc.

In June 2007 Tyco International Ltd. completed the separation of its healthcare business, which is named Covidien. Mallinckrodt, Inc. is now part of Covidien Ltd.

MRI Contrast Agents:
Contact Information
MAIL
Mallinckrodt, Inc.
675 McDonnell Blvd.
Hazelwood, MO 63042
USA
PHONE
US: (888)744-1414
International: +1-314-654-3177
FAX
+1-314-654-5380
E-MAIL
Imaging Products Customer Service:
US: Imaging Customer Service
International: icsstl@mkg.com
spacer
 
Further Reading:
  Basics:
Guerbet Completes Acquisition of Mallinckrodt’s Contrast Media and Delivery Systems Business
Sunday, 29 November 2015   by www.itnonline.com    
  News & More:
Covidien Completes Spin Off, Mallinckrodt Starts Trading On NYSE
Monday, 1 July 2013   by www.rttnews.com    
MRI Resources 
Devices - Chemistry - Spine MRI - Software - General - Safety Products
 
Molecular Imaging
 
Molecular Imaging is a new diagnostic discipline to visualize biological processes.
Molecular magnetic resonance imaging (mMRI) offers the potential to image tissues at the cellular and subcellular level. Targeted MR contrast agents enhance the diagnostic specificity and range of molecular magnetic resonance imaging.
Other modalities that can be used for noninvasive molecular imaging:
Ultrasound;
optical imaging;
positron emission tomography (PET);
single photon emission computed tomography (SPECT).


See also Nanoparticle, Monocrystalline Iron Oxide Nanoparticle, Polycrystalline Iron Oxide Nanoparticles, Liposomes, Monoclonal Antibodies, Bimodal Imaging, Tumor Specific Agents, and Intracellular Contrast Agents.
spacer

• View the DATABASE results for 'Molecular Imaging' (10).Open this link in a new window


• View the NEWS results for 'Molecular Imaging' (28).Open this link in a new window.
 
Further Reading:
  Basics:
Multimodal Nanoparticles for Quantitative Imaging(.pdf)
Tuesday, 13 December 2011   by alexandria.tue.nl    
Molecular Magnetic Resonance Imaging(.pdf)
2005   by www.medical.siemens.com    
  News & More:
Smarter MRI diagnosis with nano MRI lamp
Monday, 6 February 2017   by www.eurekalert.org    
Molecular MRI technique gives early indication of cancer treatment effectiveness
Monday, 11 April 2016   by www.healthimaging.com    
Molecular imaging and radiochemistry: the importance of instrumentation. An interview with Professor Bjorn Wangler
Thursday, 4 February 2016   by www.news-medical.net    
Positron Emission Tomographic Imaging in Stroke
Monday, 28 December 2015   by www.ncbi.nlm.nih.gov    
Potential and Limitations of Oxygen-17 MR Perfusion Measurements
Monday, 1 March 2004   by www.case.edu    
Searchterm 'Ultrasound' was also found in the following services: 
spacer
News  (70)  Resources  (55)  Forum  (6)  
 
Myocardial Late Enhancement
 
(LE) Myocardial late enhancement in contrast enhanced cardiac MRI has the ability to precisely delineate myocardial scar associated with coronary artery disease. Viability imaging implies evaluating infarcted myocardium to see whether there is enough viable tissue available for revascularization. The reversal of myocardial dysfunction is particularly relevant in patients with depressed ventricular function because revascularization improves long-term survival. In comparison to SPECT and PET imaging, myocardial late enhancement MRI demonstrates areas of delayed enhancement exactly in correlation with the infarcted region.
Viability on cardiac MRI (CMR) is based on the fact that all infarcts enhance vividly 10-15 minutes after the administration of intravenous paramagnetic contrast agents. This enhancement represents the accumulation of gadolinium in the extracellular space, due to the loss of membrane integrity in the infarcted tissue. This phenomenon of delayed hyperenhancement has been proven to correlate with the actual extent of the infarct.
MRI myocardial late enhancement can quantify the size, location and transmural extent of the infarct. If the transmural extent of the infarct (region of enhancement on MRI) is less than 50% of the wall thickness, there will be improved contractility in that segment following revascularization. In areas of hypokinesia, if there is a rim of "black" or non-infarcted myocardium that is not contracting well, it indicates the presence of hibernating myocardium, which is likely to improve after revascularization of the artery supplying that particular territory.
The total duration of a myocardial late enhancement MR imaging protocol for viability is approximately 30 minutes, including scout images, first-pass images, cine images in two planes, and delayed myocardial enhancement images. In order to assess viable myocardium, the gadolinium contrast agent is injected at a dose of 0.15 to 0.2 mmol/kg. After about 10 minutes, short axis and long axis views (see cardiac axes) of the heart are obtained using an inversion prepared ECG gated gradient echo sequence. The inversion pulse is adjusted to suppress normal myocardium. Areas of nonviable myocardium retain extremely high signal intensity, black areas show normal tissue.

For Ultrasound Imaging (USI) see Myocardial Contrast Echocardiography at Medical-Ultrasound-Imaging.com.
spacer

• View the DATABASE results for 'Myocardial Late Enhancement' (6).Open this link in a new window

 
Further Reading:
  Basics:
A Guide To Cardiac Imaging
   by www.simplyphysics.com    
  News & More:
Prediction of Myocardial Viability by MRI
1999   by circ.ahajournals.org    
Geron Demonstrates hESC-derived cardiomyocytes improve heart function after myocardial infarction
Monday, 27 August 2007   by www.brightsurf.com    
MRI Resources 
Implant and Prosthesis - Guidance - PACS - Supplies - IR - Societies
 
Quadrature Detection
 
Quadrature detection is used in magnetic resonance imaging as well as in Doppler ultrasound and is also called quadrature demodulation or phase quadrature technique.
With this phase sensitive demodulation technique the complex demodulated signal is separated into two components. One is called the real channel; the second part is called the imaginary channel and is located 90° away from the real channel. The signals from both channels are combined to produce a single set of quadrature detected real and imaginary spectra. In MRI, the parts of the demodulated MR signal are further processed by Fourier transformation analysis. All information on the MR signal components e.g. amplitude, phase, and frequency is given by this quadrature detection combined with Fourier analysis.
spacer

• View the DATABASE results for 'Quadrature Detection' (2).Open this link in a new window

MRI Resources 
General - Musculoskeletal and Joint MRI - Open Directory Project - Mobile MRI Rental - Non-English - MRI Physics
 
previous      21 - 25 (of 27)     next
Result Pages : [1 2 3 4 5 6]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



MRI is trending to low field magnets :
reduced costs will lead to this change 
AI will close the gap to high field 
only in remote areas 
is only temporary 
never 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 4 May 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]