Magnetic Resonance - Technology Information Portal Welcome to MRI Technology
Info
  Sheets

Out-
      side
 



 
 'Magnetic Field Gradient' 
SEARCH FOR    
 
  2 3 5 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Result : Searchterm 'Magnetic Field Gradient' found in 1 term [] and 47 definitions []
previous     36 - 40 (of 48)     next
Result Pages : [1]  [2 3 4 5 6 7 8 9 10]
Searchterm 'Magnetic Field Gradient' was also found in the following services: 
spacer
News  (1)  Resources  (3)  
 
Projection Reconstruction Imaging
 
MR imaging technique in which a set of projection profiles of the body is obtained by observing MR signals in the presence of a suitable corresponding set of magnetic field gradients. Images can then be reconstructed using techniques analogous to those used in conventional computed tomography (CT), such as filtered back projection. It can be used for volume imaging or, with plane selection techniques, for sequential plane imaging.
spacer
MRI Resources 
Knee MRI - Jobs pool - Service and Support - - Portals - Distributors
 
Pulsed Gradients
 
Briefly applied magnetic field gradients.

See also Bipolar Gradient Pulse and Gradient Magnetic Field.
spacer

• View the DATABASE results for 'Pulsed Gradients' (2).Open this link in a new window

MRI Resources 
Patient Information - Devices - Homepages - Spectroscopy pool - Stimulator pool - Implant and Prosthesis pool
 
Readout Gradient
 
Magnetic field gradient applied during the period when the receiver components are on. The application of this gradient, which is active during the period when the echo is being formed, results in the frequency encoding of the object being imaged.
Also called frequency encoding gradient.
spacer

• View the DATABASE results for 'Readout Gradient' (9).Open this link in a new window

 
Further Reading:
  News & More:
Evaluation of Absorbed Dose by MRI Read-Out
Saturday, 18 November 2017   by www.jstage.jst.go.jp    
Searchterm 'Magnetic Field Gradient' was also found in the following services: 
spacer
News  (1)  Resources  (3)  
 
Rotating Frame Zeugmatography
 
Technique of MR imaging that uses a gradient of the RF excitation field (to give a corresponding variation of the flip angle along the gradient as a means of encoding the spatial location of spins in the direction of the RF field gradient) in conjunction with a static magnetic field gradient (to give spatial encoding in an orthogonal direction). It can be considered to be a form of Fourier transformation imaging.
spacer
MRI Resources 
Societies - Non-English - Developers - Devices - Quality Advice - Supplies
 
SequencesForum -
related threadsInfoSheet: - Sequences - 
Intro, 
Overview, 
Types of, 
etc.MRI Resource Directory:
 - Sequences -
 
A preselected set of RF (and/or gradient) magnetic field pulses and time spacing between these pulses; used in conjunction with magnetic field gradients and MR signal reception to produce MR images.

See also Pulse Sequence , Interpulse Times and the info sheet.
spacer

• View the DATABASE results for 'Sequences' (188).Open this link in a new window


• View the NEWS results for 'Sequences' (1).Open this link in a new window.
 
Further Reading:
  News & More:
Single Sequence Magnetic Resonance Imaging in Serous Otitis Media
Friday, 28 April 2023   by www.cureus.com    
Multiacquisition with variable resonance image combination T2 (MAVRIC SL T2) for postoperative cervical spine with artificial disc replacement
Friday, 11 November 2022   by www.nature.com    
High-resolution MRI enables direct imaging of neuronal activity - DIANA – direct imaging of neuronal activity
Friday, 18 November 2022   by physicsworld.com    
What MRI Sequences Produce the Highest Specific Absorption Rate (SAR), and Is There Something We Should Be Doing to Reduce the SAR During Standard Examinations?
Thursday, 16 April 2015   by www.ajronline.org    
MRI techniques improve pulmonary embolism detection
Monday, 19 March 2012   by medicalxpress.com    
MRI Resources 
Equipment - Directories - Shielding - Stent - Artifacts - Libraries
 
previous      36 - 40 (of 48)     next
Result Pages : [1]  [2 3 4 5 6 7 8 9 10]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



MRI is trending to low field magnets :
reduced costs will lead to this change 
AI will close the gap to high field 
only in remote areas 
is only temporary 
never 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 2 May 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]