Image Acquisition Time
 
The period of time required to collect the image data. This time does not include the time necessary to reconstruct the image. The total time for performing a scan must take into consideration the additional image reconstruction time when determining how quickly the image may be viewed.
spacer

• View the NEWS results for 'Image Acquisition Time' (2).Open this link in a new window.

• View the DATABASE results for 'Image Acquisition Time' (8).Open this link in a new window

 
Further Reading:
  News & More:
Reconstructing MRI scans with AI promises to expand MRI access to more patients
Tuesday, 17 January 2023   by www.news-medical.net    
MR Fingerprinting Could Lead to Much Faster MRI Scans and Simpler Recognition of Pathology
Friday, 22 March 2013   by www.medgadget.com    
Image Contrast Characteristics
 
Variations in the value of TR and TE have an important effect on the control of image contrast characteristics.
Short values of TR (less than e.g. 1000 ms) and TE (less than e.g. 25 ms) are common in images exhibiting T1 contrast.
Long values of TR (greater than e.g. 1500 ms) and TE (greater than e.g.60 ms) are common in images exhibiting T2 contrast.
Middle TR values (e.g. from 1000 to 1500 ms) and middle TE values (e.g. from 25 to 60 ms) are common for density weighted contrast.
The values are depending on the field strength. TR is also a major factor in total scan time.
 
Images, Movies, Sliders:
 Knee MRI Coronal Pd Spir 001  Open this link in a new window
    
 Brain MRI Transversal T1 002  Open this link in a new window
    
 MRI Pancreas T2  Open this link in a new window
    
 Knee MRI Sagittal T1 004  Open this link in a new window
 Knee MRI Transverse 001  Open this link in a new window
 
Radiology-tip.comradContrast,  Low Contrast Detectability
spacer
Medical-Ultrasound-Imaging.comSonographic Features,  Echogenicity
spacer

• View the DATABASE results for 'Image Contrast Characteristics' (6).Open this link in a new window

 
Further Reading:
  Basics:
Musculoskeletal MRI at 3.0 T: Relaxation Times and Image Contrast
Sunday, 1 August 2004   by www.ajronline.org    
IMAGE CONTRAST IN MRI(.pdf)
   by www.assaftal.com    
MRI Resources 
Veterinary MRI - Sequences - MRI Technician and Technologist Jobs - MRI Technician and Technologist Career - Guidance - Lung Imaging
 
Image Data Filter
 
Various reconstruction filters can be applied to MR images to reduce noise.
spacer
Image Quality
 
The quality of magnetic resonance imaging is particularly dependent on image resolution (matrix, field of view, slice thickness), contrast (TE, TR), signal to noise ratio (bandwidth, signal averaging) and lack of artifacts. These MRI parameters are affected by the field homogeneity, the field strength, the coil, the pulse sequence type and imaging techniques like parallel imaging.

See also Image Contrast Characteristics.
spacer

• View the NEWS results for 'Image Quality' (4).Open this link in a new window.

• View the DATABASE results for 'Image Quality' (42).Open this link in a new window

 
Further Reading:
  Basics:
Image Characteristics and Quality
   by www.sprawls.org    
  News & More:
Impact of Magnetic Field Inhomogeneity on the Quality of Magnetic Resonance Images and Compensation Techniques: A Review
Saturday, 1 October 2022   by www.dovepress.com    
Researchers design 'intelligent' metamaterial to make MRIs affordable and accessible
Tuesday, 5 November 2019   by phys.org    
Patient movement during MRI: Additional points to ponder
Tuesday, 5 January 2016   by www.healthimaging.com    
Novel Imaging Technique Improves Prostate Cancer Detection
Tuesday, 6 January 2015   by health.ucsd.edu    
Image Reconstruction
 
The mathematical process of converting the composite signals obtained during the data acquisition phase into an image.
spacer

• View the DATABASE results for 'Image Reconstruction' (9).Open this link in a new window

 
Further Reading:
  Basics:
MR Image Reconstruction from Raw Data
   by dukemil.egr.duke.edu    
  News & More:
Hybrid Scanner Brings Molecular Functioning To The Forefront
Tuesday, 16 June 2009   by www.sciencedaily.com    
MRI Resources 
Image Quality - Spine MRI - Abdominal Imaging - Patient Information - Portals - Service and Support
 
    1 - 5 (of 74)      next 
 Im-Im    Im-Im   Im-Im   iM-In   In-In   In-In   In-In   In-In   In-In   In-In   In-In   In-In   In-In   Io-Is   Is-Is   
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



Next big thing in MRI will be :
AI 
remote operator 
personalized protocols 
helium-free 
molecular MRI 
portable MRI 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 18 March 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]