Aurora® 1.5T Dedicated Breast MRI SystemInfoSheet: - Devices -
Intro, 
Types of Magnets, 
Overview, 
etc.
 
From Aurora Imaging Technology, Inc.;
www.auroramri.com/mri/product/ The Aurora® 1.5T Dedicated Breast MRI System with Bilateral SpiralRODEO™ is the first and only FDA approved MRI device designed specifically for breast imaging. The Aurora System, which is already in clinical use at a growing number of leading breast care centers in the US, Europe, got in December 2006 also the approval from the State Food and Drug Administration of the People's Republic of China (SFDA).
'Some of the proprietary and distinguishing features of the Aurora System include: 1) an ellipsoid magnetic shim that provides coverage of both breasts, the chest wall and bilateral axillary lymph nodes; 2) a precision gradient coil with the high linearity required for high resolution spiral reconstruction;; 3) a patient-handling table that provides patient comfort and procedural utility; 4) a fully integrated Interventional System for MRI guided biopsy and localization; and 5) the user-friendly AuroraCAD™ computer-aided image display system designed to improve the accuracy and efficiency of diagnostic interpretations.'

Device Information and Specification
CLINICAL APPLICATION Breast MRI
CONFIGURATION Short bore compact
COILS Breast transmit receive (TR) coil
IMAGING MODES Bi-lateral RODEO fat suppression, high resolution Rotating Delivery of Excitation Offresonance Spiral, integrated targeting SW compatible with major MR guided intervention equipment.
TR 10 ms for gradient echo and less than 2,500 ms for T2 weighted spin echo
TE From 5 ms for RODEO Plus to over 80 ms, 120 ms for T2 sequences
SINGLE/MULTI SLICE Around 0.02 sec for a 256x256 image, 12.4 sec for a 512 x 512 x 32 multislice set
FOV 20 - 36 cm, max. elliptical 36 x 44 cm
MEASURING MATRIX 512 x 512
MAGNET TYPE Superconducting
BORE DIAMETER
or W x H
64 cm diameter (gantry)
MAGNET WEIGHT 8,500 lbs
H*W*D 240 x 188 x 163 cm
POWER REQUIREMENTS 150A/120V-208Y/3 Phase//60 Hz/5 Wire
COOLING SYSTEM Helium for magnet, distilled/de-ionized water for coil;
CRYOGEN USE Zero boil off rate
FIELD STRENGTH 1.5 T
spacer
 
• Share the entry 'Aurora® 1.5T Dedicated Breast MRI System':  Facebook  Twitter  LinkedIn  
 
• Related Searches:
    • Breast MRI
    • MRI Equipment
    • MRI
    • Hardware
    • Superconducting Magnet
 
Further Reading:
  Basics:
AURORA MRI System® Site Planning Guide
   by www.thorpeconstruction.com    
  News & More:
Aurora Imaging Technology Announces Approval in China
   by salesandmarketingnetwork.com    
Aurora Imaging Technology, Inc. Release: Results of a Multi-Center Trial Demonstrates Superior Diagnostic Performance of the Aurora® 1.5T Dedicated Breast MRI System Over Whole-Body Breast MRI
Monday, 1 October 2012   by www.biospace.com    
MRI Resources 
Quality Advice - Software - - General - Education - Patient Information
 
Aurora Imaging Technology, Inc.
 
www.auroramri.com Aurora Imaging Technology, Inc., a private company, is located in North Andover, Massachusetts. As a leading innovator in the breast imaging industry, the company provides with its Aurora System the detection, diagnosis, biopsy and treatment of breast cancer. Aurora Imaging Technology Inc. develops and manufactures the Aurora® 1.5T Dedicated Breast MR System, the first and only FDA approved MRI system designed specifically for breast imaging.

MRI Related Product Lines:
Aurora® 1.5T Dedicated Breast MRI System

Contact Information
MAIL Aurora Imaging Technology Inc
39 High Street
North Andover, MA 01845
USA
PHONE +1-877-975-7530
E-MAIL info@auroramri.com
ONLINE www.auroramri.com
spacer

• View the DATABASE results for 'Aurora Imaging Technology, Inc.' (2).Open this link in a new window


• View the NEWS results for 'Aurora Imaging Technology, Inc.' (5).Open this link in a new window.
MRI Resources 
Collections - Colonography - MRA - Image Quality - Pregnancy - PACS
 
     1 - 2 (of 2)     
Result Pages : [1]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?  



The impact of TTIP/TPP on the MRI scanner market will bring :
more variety 
better scanners 
more risk 
less regulation 
cheaper scanners 
Lost in Translation 
no change at all 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • US-TIP • 
Copyright © 2003 - 2018 SoftWays. All rights reserved. [ 10 December 2018]
Terms of Use | Privacy Policy | Advertising
 [last update: 2018-03-08 05:11:00]