Magnetic Resonance - Technology Information Portal Welcome to MRI Technology
Info
  Sheets

Out-
      side
 



 
 'Blood Pool Agents' 
SEARCH FOR    
 
  2 3 5 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Result : Searchterm 'Blood Pool Agents' found in 1 term [] and 15 definitions [], (+ 6 Boolean[] results
previous     11 - 15 (of 22)     next
Result Pages : [1]  [2 3 4]  [5]
Searchterm 'Blood Pool Agents' was also found in the following services: 
spacer
Resources  (2)  
 
Intravascular Contrast AgentsInfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
spacer
 
Further Reading:
  Basics:
MR angiography of collateral arteries in a hind limb ischemia model: comparison between blood pool agent Gadomer and small contrast agent Gd-DTPA.
Wednesday, 26 January 2011   by www.ncbi.nlm.nih.gov    
  News & More:
Measurement of rat brain tumor kinetics using an intravascular MR contrast agent and DCE-MRI nested model selection.
Monday, 13 January 2014   by www.ncbi.nlm.nih.gov    
Polysaccharide-Core Contrast Agent as Gadolinium Alternative for Vascular MR
Monday, 8 March 2021   by www.diagnosticimaging.com    
Searchterm 'Blood Pool Agents' was also found in the following service: 
spacer
Ultrasound  (2) Open this link in a new window
LiposomesInfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.
 
Generic name: Liposomes, central moiety: different, contrast effect: paramagnetic, distribution: different
Liposomes are lipid containing nanoparticles, or fat molecules, surrounding a water core. Liposomes were the first type of nanoparticles created to be used as carriers for lipophilic MRI contrast agents with novel characteristics.
Liposomes loaded with gadolinium-containing chelates have potential as blood pool agents, caused by modifications of the surface (e.g., with polyethylene glycol) leading to longer blood retention times.
The incorporation of contrast agents into either the the bilayer membrane or the aqueous inner cavity is possible. These MRI contrast agents has been used to image the lymph nodes using liposomes containing Gd-DTPA as well as dextran coated iron oxide particles.
To image the liver or the hepatobiliary system, liposomes containing Gd-HPDO3A, or MnDPDP, have been tested.
Liposomes containing gadolinium were conjugated to antibodies and targeted to a specific organ system.
A method of targeting tumors with ultrasound that also uses MRI to watch the cell destroying, uses liposomes loaded with cytotoxic drugs and also with gadolinium to make them show up in MRI. As well as used as an imaging technique, ultrasound can also be used to destroy cancer cells. Once the drugs have been administered, focusing the ultrasound on the target area makes blood vessels permeable. The liposomes leak out of the blood vessel into the target area, watched by MRI, where the cytotoxic drug can then go to work.

See also Memosomes, Superparamagnetic Iron Oxide, Classifications, Characteristics, etc. and Mangafodipir Trisodium.
spacer

• View the DATABASE results for 'Liposomes' (6).Open this link in a new window


• View the NEWS results for 'Liposomes' (1).Open this link in a new window.
 
Further Reading:
  Basics:
Novel Agent for Lymph Node Imaging and Targeted Gene Therapy
1997   by cbcrp.org.127.seekdotnet.com    
DELIVERY AND ACTIVATION OF CONTRAST AGENTS FOR MAGNETIC RESONANCE IMAGING(.pdf)
   by thesis.library.caltech.edu    
New MRI Contrast Agent Under Development
Friday, 16 January 2009   by www.medgadget.com    
New Method Combines MRI, HIFU, Temperature-Sensitive Liposomes for Chemo Delivery Directly to Tumor
Wednesday, 9 February 2011   by www.medgadget.com    
  News & More:
Specialized MRI sensor can detect light deep within tissues
Thursday, 22 December 2022
Multimodal Nanoparticles for Quantitative Imaging(.pdf)
Tuesday, 13 December 2011   by alexandria.tue.nl    
Molecular Magnetic Resonance Imaging(.pdf)
2005   by www.medical.siemens.com    
MRI Resources 
Most Wanted - Used and Refurbished MRI Equipment - MRCP - Brain MRI - Cardiovascular Imaging - IR
 
MS-325Forum -
related threadsInfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
MS-325 is the formerly code name of gadofosveset trisodium (new trade name Vasovist). MS-325 belongs to a new class of blood pool agents for magnetic resonance angiography (MRA) to diagnose vascular disease. Gadofosveset trisodium has ten times the signal-enhancing power of existing contrast agents as well as prolonged retention in the blood. This enables the rapid acquisition of high resolution MRA's using standard MRI machines.
Gadofosveset trisodium, which is gadolinium-based, stays in the blood stream as a result of transient binding to albumin. Albumin binding offers an additional benefit beyond localization in the blood pool. The contrast agent begins to spin much more slowly, at the rate albumin spins, causing a relaxivity gain that produces a substantially brighter signal than would be possible with freely circulating gadolinium. MS-325 is an intravascular contrast agent intended for use in MRI as an aid in diagnosing aortoiliac occlusive disease in patients with known or suspected peripheral vascular disease (PVD) or abdominal aortic aneurysm (AAA).
Currently clinical trials completed for peripheral vascular disease and coronary artery disease. Additional trials are also being conducted to evaluate MS-325 as an aid in diagnosing breast cancer and suggested that it might be feasible to combine the use of MS-325, injected during peak stress, with delayed high-resolution imaging to identify myocardial perfusion defects.
Vasovist (MS-325) would compete with the contrast agents Ferumoxytol (Code 7228) from AMAG Pharmaceuticals, Inc. and NC100150 Injection from Nycomed Amersham, but their further development is uncertain.
Partners in development: EPIX Pharmaceuticals, Inc., Mallinckrodt Inc., and Bayer Schering Pharma AG. Bayer Schering Pharma has the worldwide marketing rights for the product.
Formerly known under the Mallinckrodt trademark name, AngioMARK®.

See also Classifications, Characteristics, etc.
spacer

• View the DATABASE results for 'MS-325' (4).Open this link in a new window


• View the NEWS results for 'MS-325' (10).Open this link in a new window.
 
Further Reading:
  News & More:
EPIX Medical's new multimedia Web site features AngioMARK images in 3D
Friday, 5 March 1999
MRI technology combined with contrast agent optimizes diagnosis of cardiovascular disease
1999
Searchterm 'Blood Pool Agents' was also found in the following services: 
spacer
Resources  (2)  
 
Supravist™InfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
Short name: SHU 555 C, preliminary trade name: Supravist™
An ultrasmall superparamagnetic iron oxide under development as a positive enhancing blood pool agent (MRI contrast agent phase III, Bayer Schering Pharma AG). Supravist™ can be administered as an iv. bolus up to doses of 80 μmol/kg.

See also Ultrasmall Superparamagnetic Iron Oxide and Blood Pool Agents.
spacer

• View the DATABASE results for 'Supravist™' (3).Open this link in a new window

Searchterm 'Blood Pool Agents' was also found in the following service: 
spacer
Ultrasound  (2) Open this link in a new window
Ultrasmall Superparamagnetic Iron OxideInfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.
 
(USPIO) The class of the ultrasmall superparamagnetic iron oxide includes several chemically and pharmacologically very distinct materials, which may or may not be interchangeable for a specific use. Some ultrasmall SPIO particles (median diameter less than 50nm) are used as MRI contrast agents (Sinerem®, Combidex®), e.g. to differentiate metastatic from inflammatory lymph nodes. USPIO shows also potential for providing important information about angiogenesis in cancer tumors and could possibly complement MRI helping physicians to identify dangerous arteriosclerosis plaques.
Because of the disadvantageous large T2*//T1 ratio, USPIO compounds are less suitable for arterial bolus contrast enhanced magnetic resonance angiography than gadolinium complexes. The tiny ultrasmall superparamagnetic iron oxides do not accumulate in the RES system as fast as larger particles, which results in a long plasma half-life. USPIO particles, with a small median diameter (less than 10 nm), will accumulate in lymph nodes after an intravenous injection by e.g. direct transcapillary passage through endothelial venules. Once within the nodal parenchyma, phagocytic cells of the mononuclear phagocyte system take up the particles.
As a second way, USPIOs are subsequently taken up from then interstitium by lymphatic vessels and transported to regional lymph nodes. A lymph node with normal phagocytic function takes up a considerable amount and shows a reduction of the signal intensity caused by T2 shortening effects and magnetic susceptibility. Caused by the small uptake of the USPIOs in metastatic lymph nodes, they appear with less signal reduction, and permit the differentiation of healthy lymph nodes from normal-sized, metastatic nodes.

See also Superparamagnetic Contrast Agents, Superparamagnetic Iron Oxide, Very Small Superparamagnetic Iron Oxide Particles, Blood Pool Agents, Intracellular Contrast Agents.
spacer

• View the DATABASE results for 'Ultrasmall Superparamagnetic Iron Oxide' (16).Open this link in a new window


• View the NEWS results for 'Ultrasmall Superparamagnetic Iron Oxide' (2).Open this link in a new window.
 
Further Reading:
  Basics:
Comparison of Two Superparamagnetic Viral-Sized Iron Oxide Particles Ferumoxides and Ferumoxtran-10 with a Gadolinium Chelate in Imaging Intracranial Tumors
2002   by www.ajnr.org    
  News & More:
Optimized Labelling of Human Monocytes with Iron Oxide MR Contrast Agents
Sunday, 30 November 2003   by rsna2003.rsna.org    
10 SUMMARY AND FUTURE PERSPECTIVES
   by dissertations.ub.rug.nl    
MRI Resources 
Portals - Most Wanted - Fluorescence - Raman Spectroscopy - Education - MRI Centers
 
previous      11 - 15 (of 22)     next
Result Pages : [1]  [2 3 4]  [5]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



How AI will impact MRI :
only diagnostics 
saving time 
reducing cost 
makes planning obsolete 
reduce human knowledge 
not at all 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 3 May 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]