Travis Conley

Thu. 21 Oct.10,
17:22

[Start of:
'Muscle shading in 3T Images'
2 Replies]


 
  Category: 
Applications and Examinations

 
Muscle shading in 3T Images
We are using a 3T GE scanner to image axial slices of human thigh muscle for the purpose of quantifying muscle volume. rnrnProblem: Our images have been presenting some shading at the top and bottom of each slice. We have tried everything we can think of to get rid of this shading but have not been sucessful. rnrnI have attached a representative image and would love some feel back. rnrnThanks so much for attempting to help us out.
 
 
Thigh Axial Slice


 View the whole threadReply to this thread
(login or register first)
Jacob Newton

Thu. 7 Oct.10,
19:22

[Reply (1 of 2) to:
'How does TE affect DWI acquisition?'
started by: 'danilo Scelfo'
on Wed. 29 Sep.10]


 
  Category: 
Sequences and Imaging Parameters

 
How does TE affect DWI acquisition?
I never tried to shorten only the echo time while keeping all other parameters the same, but I would expect a change in SNR and artifact appearance. I would use parallel imaging methods to get a shortest possible echo time. Parallel imaging provides DWI with shorter echo trains associated with further reduction of the echo and repetition times, which reduces susceptibility effects and also image blurring. Additionally, the shorter echo time may lead to changes in ADC measurement.
 View the whole thread
danilo Scelfo

Wed. 29 Sep.10,
12:15

[Start of:
'How does TE affect DWI acquisition?'
1 Reply]


 
  Category: 
Sequences and Imaging Parameters

 
How does TE affect DWI acquisition?
Hi folk! Just a breath question: how does TE affect conventional sequence (single shot SE-EPI) for DWI acquisition? In particular, how would two acquisitions differ from each other if acquired with TE=90/106ms respectively (being equal all the other parameters, i.e. TR=11s, same FOV, …)? Thanks for any opinion you will give me. Danilo.
 View the whole threadReply to this thread
(login or register first)
steven china

Fri. 24 Sep.10,
12:12

[Reply (3 of 4) to:
'coil configuration'
started by: 'Zhenghui Zhang'
on Thu. 24 Jun.04]


 
  Category: 
Coils

 
coil configuration
hi buddy
in general,surface coils are designed for receive signals only and have no fuction of transmit
 View the whole thread
adam wootton

Thu. 26 Aug.10,
16:58

[Reply (2 of 3) to:
'3T imaging parameters'
started by: 'Nancy Dudek'
on Fri. 26 Aug.05]


 
  Category: 
Sequences and Imaging Parameters

 
3T imaging parameters
All your parameters will be the same in a 3T as in the 1.5T except for the T1's TR. T1 TR is 700 to 1300.
 View the whole thread

Result Pages : 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 [41] 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 
 top
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



Look
      Ups






MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 15 May 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]