Magnetic Resonance - Technology Information Portal Welcome to MRI Technology
Info
  Sheets

Out-
      side
 

Next big thing in MRI will be :
AI 
remote operator 
personalized protocols 
helium-free 
molecular MRI 
portable MRI 




 
MRI Forum
'tr'
SEARCH FORUM FOR   
 
Result: Searchterm 'tr' found in 420 messages
Result Pages: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 [19] 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 
More Results: Database  (1011)  News Service  (1852)  Resources  (540)  
Forum Overview
 bottom
tracie smith

Thu. 8 Dec.16,
16:11

[Reply (20 of 21) to:
'MRI registry equations'
started by: 'Donna Nusser'
on Tue. 18 Aug.09]


 
  Category: 
Basics and Physics

 
MRI registry equations
Hi i saw your post to this forum and i am studying for the MRI registry as well. I have taken it twice and scored a 74 last time. This is my final attempt and i saw threads with people sharing info and study guides. I wasn't sure how to post to the main forum but if you could repost this to the main forum that would be appreciated so much. if anyone can email any information or study test etc. I am so nervous being my third attempt and ive been out of school so long lol My job is on the line if I dont pass. Ive been studying MRI in Practice hopefully that will help but I just wanted to leave my email address traciem218@gmail.com if anyone has any study hints ect. please send them Im in desperate need to pass this. I hope yours went well if you've taken it yet. Thanks in advance for any infornTraciern
 View the whole thread
Desiree Dupuy

Sat. 3 Dec.16,
22:14

[Reply (2 of 3) to:
'Muscle shading in 3T Images'
started by: 'Travis Conley'
on Thu. 21 Oct.10]


 
  Category: 
Applications and Examinations

 
Muscle shading in 3T Images
Try running a B1 Map followed by Calibration. Set RF Drive mode to Optimized. This is supposed to optimize for your Patient. Supposed to reduce dielectric effect/shading for Lumbar and Abdomen.
You can find under GE Additional Abdomen Sequences.

Or you can run Ideal with Dixon technique. Turn on IN phase will give you T1 FS & IN Phase is you plane T1. I believe this takes care of the artifact.
 View the whole thread
Martin Rosellen

Wed. 19 Oct.16,
15:30

[Start of:
'k space explanation'
2 Replies]


 
  Category: 
General

 
k space explanation
dear all,
I am trying to get a feel for what k-space is. So far I have not got an explanation that I understand. My idea to picture the frequencies that get emmitted from a slice as follows: - We have a box filled with still waterrn - a set of objects get dropped into the water simultaneously - every object emmits waves that are specific to its shape. To fill k space, what is measured and how? All I know is that the sampling frequency stays the same. Sorry for the ugly formatting. Did not find help on that. Thanks Martin
 View the whole threadReply to this thread
(login or register first)
Cristobal Bertoglio

Mon. 1 Aug.16,
21:59

[Start of:
'PCMRI'
0 Reply]


 
  Category: 
General

 
PCMRI
Hi everybody

I am curious to understand a bit better what the formula that it is used in PCMRI for relating the change of phase and the velocity assume ...

As far I have unterstand that it is assumed the phase of a moving particle can be measured at two time instants, i am right? Does this not assume we can "track" the particle? Does this not "contradict" the fact that we can only compare phases that we measure at the same fixed place?

Thanks,

C.
Reply to this thread
(login or register first)
Eduardo Mendes

Tue. 19 Jul.16,
12:59

[Start of:
'Need to quench a scanner now'
2 Replies]


 
  Category: 
General

 
Need to quench a scanner now
HellornrnI have on old Oxford 4.7 T scanner that has been working since 2011. Unfortunately these last few days we could not transfer He in. Although our He liquefier is completely full and the transfer line is connect to the magnet, no He is transferred. The transfer line has been made vacuo efficient two months ago and should be ok. rnrnIt seems that we need to quench the magnet. We don't have any external power supply to connect to the magnet and retrieve the current. rnrnWhat can we do? Is there any safety measures? Can we leave the magnet as it is? Should we evacuate the building? Should we isolate the area? rnrnThank you ever so much for your time and help. rnrnI have contacted Oxford several times but they didn't return my emails. rnrnMany thanksrnrnEdrnrn
 View the whole threadReply to this thread
(login or register first)

Result Pages : 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 [19] 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 
 top
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



Look
      Ups






MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 15 May 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]