Haemorrhages
 
After a bleeding, blood goes through several transitions regarding magnetic properties, intra- and extracellular distribution and content of proteins and water. Oxyhaemoglobin is degraded to deoxyhaemoglobin and further to methaemoglobin, ferritin and haemosiderin. These molecules can be characterized by their magnetic susceptibility effect. Oxyhaemoglobin is diamagnetic with no practical influence on the magnetic field. All degradation products are paramagnetic (deoxyhaemoglobin, methaemoglobin) or even superparamagnetic (ferritin, haemosiderin).

See also Haemoglobin, Blood Oxygenation Level Dependent Contrast.
spacer
 
• Share the entry 'Haemorrhages':  Facebook  Twitter  LinkedIn  
 
Further Reading:
  News & More:
Spinal bleeding with brain injury may suggest abuse in young children
Tuesday, 8 November 2011   by www.eurekalert.org    
MRI measurement tools to help diagnose veterans' traumatic brain injuries
Wednesday, 18 March 2015   by medicalxpress.com    
MRI Resources 
MRI Accidents - Distributors - MRI Reimbursement - Databases - Contrast Enhanced MRI - Equipment
 
Gradient EchoForum -
related threads
 
(GE) An echo signal generated from a free induction decay by means of a bipolar switched magnetic gradient. The echo is produced by reversing the direction of a magnetic field gradient or by applying balanced pulses of magnetic field gradient before and after a refocusing RF pulse so as to cancel out the position dependent phase shifts that have accumulated due to the gradient.
In the latter case, the gradient echo is generally adjusted to be coincident with the RF spin echo. When the RF and gradient echoes are not coincident, the time of the gradient echo is denoted echo time (TE) and the difference in time between the echoes is denoted time difference (TD).
Gradient echo does not refocus the effects of main field inhomogeneity and therefore is generally used with a short echo time. Disadvantages of gradient echo imaging are compromised anatomic details and artifacts in regions with varying susceptibility e.g. between the air-containing sinuses and brain and especially between haemorrhages and normal tissue.

See also Susceptibility Artifact.
spacer

• View the DATABASE results for 'Gradient Echo' (121).Open this link in a new window

 
Further Reading:
  Basics:
Mapping of low flip angles in magnetic resonance(.pdf)
Saturday, 1 January 2011   by www.hal.inserm.fr    
A LANTHANIDE LANTHOLOGY(.pdf)
   by www.phy.davidson.edu    
Enhanced Fast GRadient Echo 3-Dimensional (efgre3D) or THRIVE
   by www.mri.tju.edu    
MRI Resources 
Equipment - IR - MRI Technician and Technologist Jobs - Image Quality - Non-English - Stent
 
     1 - 2 (of 2)     
Result Pages : [1]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



MRI is trending to low field magnets :
reduced costs will lead to this change 
AI will close the gap to high field 
only in remote areas 
is only temporary 
never 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 26 April 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]