Bear DuDu

Sun. 4 Jun.06,
09:30

[Reply (1 of 3) to:
'ZIP512'
started by: 'Shaun Schofield'
on Thu. 30 Mar.06]


 
  Category: 
Sequences and Imaging Parameters

 
ZIP512
when you use low matrix (lower than 256x256), you may use zip512 to increase the display resolution of image.

if the matrix is larger than 256x256, the system automatically use zip512.
 View the whole thread
Michael Semrau

Tue. 30 May.06,
20:18

[Reply (1 of 2) to:
'help me for looking for some gadolinium product'
started by: 'Linqing Li'
on Fri. 21 Oct.05]


 
  Category: 
Contrast Agents

 
help me for looking for some gadolinium product
Linquing,
just saw your thread, and at the same moment this advertisement in another browser:
http://www.baotou.com/
It seems they are trading gadolinium products around the globe.

Regards
Michael
 View the whole thread
Michael Oliver

Sat. 27 May.06,
12:54

[Reply (1 of 3) to:
'ETL for a STIR'
started by: 'Shaun Schofield'
on Thu. 30 Mar.06]


 
  Category: 
Sequences and Imaging Parameters

 
ETL for a STIR
I prefer a range from 5-12 (but using shorter TE and TR). High echo trains can lead to blurring, image noise and contrast inhomogeneities.
Parallel imaging can reduce the longer scan time of low ETLs; also often 1 NSA is enough for sufficient SNR.

Hope this helps!
 View the whole thread
Reader Mail

Sun. 21 May.06,
13:53

[Reply (1 of 3) to:
'What Philips calls bandwidth'
started by: 'Anne Nelson'
on Thu. 4 May.06]


 
  Category: 
General

 
What Philips calls bandwidth
The corresponding term is the water fat shift and can be changed in the contrast parameter table.
Lower bandwidth = higher water fat shift
 View the whole thread
Donna Ponticello

Sun. 21 May.06,
13:49

[Reply (1 of 2) to:
'Omniscan Distribution Rate'
started by: 'John Dowling'
on Tue. 9 May.06]


 
  Category: 
Contrast Agents

 
Omniscan Distribution Rate
I do not doubt that there are small and may be in special cases (perfusion, MRA, etc.) useful differences.
However, I have a lot of practice in MRI and in my opinion, you are right, the differences are small and you can run every type of MRI scans with all conventional Gadolinium containing contrast agents.
 
 

D. P.
 View the whole thread

Result Pages : 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 [73] 74 75 76 77 78 79 80 81 82 83 84 85 
 top
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



Look
      Ups






MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2025 SoftWays. All rights reserved. [ 8 May 2025]
Terms of Use | Privacy Policy | Advertising
 [last update: 2025-04-05 02:38:00]