Renate Bloemer
Wed. 14 Jun.06, 22:22
[Reply (1 of 2) to: 'T1/T2 relaxation time charts' started by: 'Reader Mail' on Fri. 12 May.06]
Category:
General |
T1/T2 relaxation time charts |
You can find a table of the approximate values of the two relaxation time constants and some relevant formulas on:
http://en.wikipedia.org/wiki/T2*
|
| View the whole thread | | |
Shaun Schofield
Thu. 30 Mar.06, 04:07
[Start of: 'ETL for a STIR' 2 Replies]
Category:
Sequences and Imaging Parameters |
ETL for a STIR |
Whats the ETL range for a STIR? Assuming 50TE 5000TR 150TI.
Does it follow the T2 parameters? Can someone give me the pros/cons of high versus low ETL?
|
| View the whole thread | Reply to this thread (login or register first) | |
Abraham Morejon
Wed. 30 Nov.05, 13:52
[Start of: 'Whole Body Scan MRI' 0 Reply]
Category:
Sequences and Imaging Parameters |
Whole Body Scan MRI |
Can anyone tell me what FOV is used on a 2 year old whole body scan? , On an adult whole body scan ? , and how many table moving stations are needed for an adult whole body scan? I am doing a coronal Stir,T1 FFE coronal and a SSFSE T2W coronal.
|
| | Reply to this thread (login or register first) | |
Susan Angelico
Thu. 15 Sep.05, 20:07
[Reply (1 of 3) to: '3T imaging parameters' started by: 'Nancy Dudek' on Fri. 26 Aug.05]
Category:
Sequences and Imaging Parameters |
3T imaging parameters |
At 3T the T1 time is longer (so the TR should also be longer) and the T2 time is shorter (TE can be shorter). However, when we got a 3T machine we tested different TR and TE's and found out that in practice the useful range don't has a big difference from that of a 1.5T MR system.
The contrast looks a bit different - that's normal.
In addition, ask the manufacturer.
There are a lot of other parameters that affect the contrast in 3T.
Hope this will help
|
| View the whole thread | | |
purna chander reddy
Sun. 11 Sep.05, 14:46
[Reply (3 of 6) to: 'Brain Protocol' started by: 'Oscar Cidri' on Tue. 7 Sep.04]
Category:
Protocols |
Brain Protocol |
hai
according to pt histry we went for seq for brain routine
T2,FLAIR,T1 TRANSVERSAL
T1 SAGITALS
T2,IR CORONOL
|
| View the whole thread | |
| |