Reader Mail

Tue. 26 Jul.11,
14:05

[Start of:
'MR750: ASSET Artifact or 32 Channel coil?'
1 Reply]


 
  Category: 
Funktional MRI

 
MR750: ASSET Artifact or 32 Channel coil?
Hi,

We are performing fMRI on a GE MR750 Discovery.
As you can see we get artifacts when performing DTI and fMRI.
It looks like herringbones or spikes artifacts. But it appears only at the very top slices where there is generally no more brain.
One possible explanation is that ASSET will produce the artifact where there is no signal.
Another explanation would be that some element of the 32 channel coil is going mad.
Has anybody experienced the same artifact?

Thank you.
 
 
DTI artifact


 View the whole threadReply to this thread
(login or register first)
Bear DuDu

Thu. 18 Oct.07,
07:39

[Reply (1 of 5) to:
'DTI 25 directions on GE signa excite 1.5'
started by: 'Gonzalo Sanchez Benavides'
on Tue. 5 Jun.07]


 
  Category: 
Sequences and Imaging Parameters

 
DTI 25 directions on GE signa excite 1.5
you will find the table of dti directions in the /usr/g/bin/tensor.dat
it's a text file. use ftp software to download it.
 View the whole thread
Johan J

Thu. 8 Feb.07,
20:51

[Reply (2 of 3) to:
'visualizing corticospinal tracts'
started by: 'marleen michels'
on Wed. 22 Nov.06]


 
  Category: 
Applications and Examinations

 
visualizing corticospinal tracts
With DTI you're able to visualize the coricospinal tracts. Not to difficult actually, you'll just need the proper gear and post processing software.

Cheers
 View the whole thread
corey walker

Thu. 26 Oct.06,
19:29

[Start of:
'pgh to dicom conversion?'
1 Reply]


 
  Category: 
General

 
pgh to dicom conversion?
I am using new dti software that will not read pgh. Unfortunately, a large amount of our data was stored in pgh format only. As this software does not read pgh, is there any way to convert pgh format into dicom? I have had no luck with this so far.
 View the whole threadReply to this thread
(login or register first)
Dirk Noel

Thu. 17 Jun.04,
04:38

[Reply (1 of 2) to:
'dynamic stabilization'
started by: 'ranran wu'
on Sun. 6 Jun.04]


 
  Category: 
Sequences and Imaging Parameters

 
dynamic stabilization
HI Ranran,


Dynamic Stabllization should be used for DTI imgaing. Especially if you are using a high number directions. The reason is that overtime you may get a F0 drift. Using DTI and DS helps for image consistency across all directions.
Hope this helps

Dirk
 View the whole thread

Result Pages : 1 [2] 
 top
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



Look
      Ups






MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 19 May 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]