Titanium & MRI Safety
I am trying to understand why titanium is considered "MRI Safe".

I see three potential problems when considering the MRI safety of a material:

1 - If it is a ferromagnetic material extreme damaging forces will be applied to the material if exposed to a very strong magnetic field. Titanium is not a magnetic material so I do not see this as a problem.

2 - When a relatively large flat conductor (e.g. a titanium plate) is exposed to a changing magnetic field (Faraday's law) eddy currents will be created internally as the result of induced voltages. These eddy currents can be very high and cause resistive heating ("I squared R losses"). I would think these eddy currents would have the potential to cause extreme heating of the titanium. I know from experience this does occur with steel and titanium has a conductivity about the same as steel. Titanium is not magnetic as is steel but induced voltages due not require a ferromagnetic material (.e.g. copper as used in real world generators, etc.).

3 - Induced voltages are created across the length of a conductor as the result of the conductor being exposed to a changing magnetic field ("genrator effect" - Faraday's Law). Again this effect does not require a magnetic material. So why, at best, does this effect not have the potential to be uncomfortable or even very painful to the MRI patient being exposed to a huge changing magnetic field?

Invariably the response to why titanium is safe focuses on the fact that it is not magnetic. I get the deer in the headlight look when I ask about eddy current heating and induced voltages.

Please help me understand why unduced eddy current heating and induce voltages are not a concern.


 View the whole threadReply to this thread
(login or register first)

Result Pages : [1] 
 top
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



Look
      Ups






MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 28 April 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]