Quadrature CoilInfoSheet: - Coils - 
Intro, 
Overview, 
etc.MRI Resource Directory:
 - Coils -
 
A coil that produces an RF field with circular polarization. The RF power received from the RF power amplifier comes in two signals (quadrature detection), which have a phase difference of 90°. The RF transmit coil converts the power into a circularly polarized RF magnetic field.
Quadrature coils can be used as both, transmit and/or receive coil. When used as a transmitter coil a factor of two power reduction over a linear coil results; as a receiver an increase in SNR of up to a factor of √2, can be achieved.

See also the related poll result: '3rd party coils are better than the original manufacturer coils'
spacer
 
• Related Searches:
    • Coil Loading
    • Imaging Coil
    • Saddle Coil
    • Hardware
    • Array Coil
 
Further Reading:
  News & More:
HEAD AND NECK MRI GRADIENT COIL DESIGN
Thursday, 26 August 1999   by www.imaging.robarts.ca    
MRI Resources 
Distributors - Implant and Prosthesis - Software - Devices - MRI Centers - Sequences
 
Volume CoilInfoSheet: - Coils - 
Intro, 
Overview, 
etc.MRI Resource Directory:
 - Coils -
 
Radio frequency coil that surrounds either the whole body, or one specific region, such as the head or a knee. Volume coils have a better RF homogeneity than surface coils, which extends over a large area. The most commonly used design is a (birdcage) bird cage coil. This consists of a number of wires running along the z-direction, arranged to give a cosine current variation around the circumference of the coil. It is possible to use the same coil to transmit and receive, or to use two separate coils. The largest volume coil, the body coil is typically a transmit and receive coil. If two separate coils are used, works the body coil as the transmitter and a smaller coil as the receiver.

See also the related poll result: '3rd party coils are better than the original manufacturer coils'
spacer

• View the DATABASE results for 'Volume Coil' (5).Open this link in a new window

 
Further Reading:
  News & More:
HEAD AND NECK MRI GRADIENT COIL DESIGN
Thursday, 26 August 1999   by www.imaging.robarts.ca    
MRI Resources 
Safety Training - Veterinary MRI - Spectroscopy pool - Mass Spectrometry - Implant and Prosthesis - Case Studies
 
previous      21 - 22 (of 22)     
Result Pages : [1]  [2 3]  [4 5]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



MRI is trending to low field magnets :
reduced costs will lead to this change 
AI will close the gap to high field 
only in remote areas 
is only temporary 
never 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 7 May 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]