UltraSound - Technology Information PortalSaturday, 23 March 2019
Info
  Sheets



Out-
      side
 




 
 'Echocardiography' 
SEARCH FOR   
 
  12345ABCDEFGHIJKLMNOPQRSTUVWZ
Result : Searchterm 'Echocardiography' found in 7 terms [] and 29 definitions [])
previous     21 - 25 (of 36)     next
Result Pages : [1 2]  [3 4 5 6 7 8]
Searchterm 'Echocardiography' was also found in the following services: 
spacer
News  (43)  Resources  (33)  Forum  (1)  
 
Imagent®InfoSheet: - Contrast Agents - 
Intro, 
Historical Development, 
Microbubbles,
etc.MRI Resource Directory:<br> - Contrast Agents -
 
Imagent® is an injectable suspension for intravenous administration during a sonogram. This diagnostic contrast agent for enhancement of ultrasound images contains perflexane lipid microspheres. Imagent® US is indicated in the assessment of heart function and perfusion, as well as the detection of tumors and blood flow abnormalities by using gray scale, color Doppler, and harmonic ultrasound imaging techniques.
During the course of its development, the brand name for this product has changed from Imagent to Imavist (between August 2000 and March 2002) back to Imagent. The manufacturer's 06/03/02 press release announcing FDA approval refers to the product as "Imagent (formerly Imavist)," and the approval notice and monograph posted at the FDA site refers to the product as Imagent.
Jointly developed by Alliance Pharmaceutical Corporation and Schering AG (Germany). Source: PR Newswire - 10/10/96, 03/31/98, 10/13/99, 03/13/01, 10/08/01; FDA approvals - 05/31/02; Alliance Pharmaceutical press release - 06/03/02.

Drug Information and Specification:
RESEARCH NAME AF0150
DEVELOPER IMCOR Pharmaceuticals, Inc.
INDICATION -
DEVELOPMENT STAGE
Echocardiography
APPLICATION Intravenous
TYPE Microbubbles
SHELL Lipid: DMPC
CHARGE Neutral
GAS Perfluorohexane/Nitrogen
MICROBUBBLE SIZE 99.8% < 10µm
PRESENTATION -
STORAGE Room Temp 15–30°C
PREPARATION Reconstitute with 10 ml water
DO NOT RELY ON THE INFORMATION PROVIDED HERE, THEY ARE NOT A SUBSTITUTE FOR THE ACCOMPANYING PACKAGE INSERT!

Distribution Information:
TERRITORY DISTRIBUTOR
USA, EU Bristol-Myers Squibb Medical Imaging, Inc.

spacer
• Related Searches:
    • Noise
    • Imagic
    • Analog
    • Fetal Ultrasound
    • Hitachi Medical Systems America Inc.(USA)/Hitachi Medical Corp.(Tokyo)

 Further Reading:
  Basics:
CONTRAST ECHOCARDIOGRAPHY: NEW AGENTSOpen this link in a new window
   by eurheartj.oxfordjournals.org    
  News & More:
The role of ultrasound in molecular imaging(.pdf)Open this link in a new window
2003   by bjr.birjournals.org    
IMCOR Pharmaceutical Co., Alliance Pharmaceutical Corp., Molecular Biosystems, Inc. and GE Healthcare Ltd., Inc. Enter Into Cross-Licensing Agreement for Ultrasound Contrast PatentsOpen this link in a new window
   by www.prnewswire.com    
Searchterm 'Echocardiography' was also found in the following services: 
spacer
Radiology  (4) Open this link in a new windowMRI  (2) Open this link in a new windowMarket  (1) Open this link in a new window
iU22InfoSheet: - Devices -
Intro, 
TypesMRI Resource Directory:<br> - Devices Machines Scanners Systems -
 
www.medical.philips.com/main/products/ultrasound/general/iu22/

From Philips Medical Systems;
'The Philips iU22 system combines Intelligent Design, including breakthroughs in ergonomics, with Intelligent Control, providing new levels of automation, to give you revolutionary performance and workflow.'

Device Information and Specification
APPLICATIONS Abdominal, cardiac (also for adults with TEE), musculoskeletal (also pediatric), OB/GYN, prostate, small parts, transcranial, vascular
CONFIGURATION 17" high resolution non-interlaced flat CRT, 4 active probe ports
RANGE OF PROBE TYPE Multi-frequency, 4D, convex - micro convex, phased array, linear, specialty
TRANSDUCERS -
IMAGING MODES B-mode, M-mode, coded harmonic imaging, color flow mode (CFM), power Doppler imaging (PDI), color Doppler, pulsed wave Doppler, tissue harmonic imaging
IMAGING OPTIONS CrossXBeam spatial compounding, coded ultrasound acquisition),speckle reduction imaging (SRI), TruScan technology store raw data, CINE review with 4 speed types
OPTIONAL PACKAGE Transesophageal scanning, stress echo, tissue velocity imaging (TVI), tissue velocity Doppler (TVD), contrast harmonic imaging
STORAGE, CONNECTIVITY, OS Patient and image archive, HDD, DICOM 3.0, CD/DVD, MOD, Windows-based
DATA PROCESSING Digital beamformer with 1024 system processing channel technology
H*W*D m (inch.) 1.62 * 0.61 * 0.99 (64 * 22 * 43)
WEIGHT kg (345 lbs.)
POWER CONSUMPTION
spacer

 Further Reading:
  Basics:
iU22 Ultrasound SystemOpen this link in a new window
   by www.medical.philips.com    
US Resources  
Patient Information - Pelvic - Doppler UltraSound - Artifacts - Endoscopic - Thyroid
 
Lateral ResolutionMRI Resource Directory:<br> - Image Quality -
 
Lateral resolution is the minimum separation of two interfaces aligned along a direction perpendicular (objects that are side by side) to the ultrasound beam. The lateral or angular resolution directly relates with the collimation of the beam emitted by the crystal. Lateral resolution is proportionally affected by the frequency, the higher the frequency the greater the lateral resolution.
Higher frequency transducers are used in fetal and pediatric echocardiography because the lateral resolution displays the smaller structures better. Lower frequencies are used for adults where structures are larger and the need for greater depth penetration is important.
spacer

 Further Reading:
  Basics:
Ultrasound Physics Main differences between Ultrasound and X-rays, Velocity of sound in some Biological MaterialsOpen this link in a new window
   by www.drgdiaz.com    
Physics, instrumentation and basic technique.Open this link in a new window
   by dynamicultrasound.org    
Searchterm 'Echocardiography' was also found in the following services: 
spacer
News  (43)  Resources  (33)  Forum  (1)  
 
Left Ventricular OpacificationMRI Resource Directory:<br> - Heart -
 
(LVO) Ultrasound contrast agents improve the echocardiography assessment of left ventricular function and the low sensitivity of changes in left ventricular ejection fraction (LVEF). In addition, harmonic imaging techniques and automated border detection (ABD) together with contrast enhanced left ventricular opacification increase endocardial border delineation (EBD) and the results compared to native echocardiography.
Radiology-tip.comGated Blood Pool Scintigraphy
spacer
Radiology-tip.comCardiac MRI
spacer

 Further Reading:
  Basics:
Combination of contrast with stress echocardiography: A practical guide to methods and interpretationOpen this link in a new window
2004   by www.cardiovascularultrasound.com    
Searchterm 'Echocardiography' was also found in the following services: 
spacer
Radiology  (4) Open this link in a new windowMRI  (2) Open this link in a new windowMarket  (1) Open this link in a new window
Levovist®InfoSheet: - Contrast Agents - 
Intro, 
Historical Development, 
Microbubbles,
etc.MRI Resource Directory:<br> - Contrast Agents -
 
From Schering AG
Available in Europe since 1996 and in Japan since 1999
Levovist® is a first generation USCA consisting of galactose (milk sugar) ground into tiny crystals whose irregular surfaces act as nidation sites on which air pockets form when it is suspended in water, much as soda water bubbles form at small irregularities on the surface of the glass. A trace of palmitic acid is added as a surfactant to stabilize the resultant microbubbles. When Levovist® dissolves in blood, air trapped inside the galactose is released as free gas bubbles. These bubbles have a weak encapsulating shell and are easily destroyed by ultrasound.
Different contrast ultrasonography methods have been developed since the introduction of Levovist®. Initially, Levovist® was an echo contrast medium for improving sensitivity in color Doppler and Power Doppler examinations, but was found to suffer from significant blooming, making it difficult to observe small blood vessels. However, Levovist® improves the accuracy of echocardiographic examinations in such indications as assessment of left ventricular function.
In addition to their vascular phase, some USCAs can exhibit a tissue- or organ-specific phase. Levovist® can accumulate within the liver and the spleen for up to 20 min once it has disappeared from the blood pool and improves the detectability of focal liver lesions and allows more reliable control of interventional tumor treatments. Varied types of information can be obtained by applying contrast imaging at different times after the injection using Levovist® in both the arterial phase and the late organ-specific phase.
1 g Levovist® granules contain 999 mg D-galactose and 1 mg palmitic acid.
Brand names in other countries: Levovist/Levograf

Drug Information and Specification:
RESEARCH NAME SHU 508A
DEVELOPER Schering AG
INDICATION -
DEVELOPMENT STAGE
Vascular sonography and echocardiography, LVO//Doppler -
For sale
APPLICATION Intravenous injection
TYPE Microbubble
SHELL Galactose/Palmitic acid
CHARGE Negative
GAS Air
MICROBUBBLE SIZE 95% < 10µm
PRESENTATION Vials of 2.5 g and 4.0 g incl. one plastic ampoule containing 20 ml water for injection, one mini-spike and one disposable syringe of 20 ml
STORAGE Room temp 15–30°C
PREPARATION Reconstitute with 5 to 17 ml water
DO NOT RELY ON THE INFORMATION PROVIDED HERE, THEY ARE NOT A SUBSTITUTE FOR THE ACCOMPANYING PACKAGE INSERT!

Distribution Information:
TERRITORY DISTRIBUTOR
EU, Canada, Japan Schering AG

spacer

 Further Reading:
  Basics:
Levovist®(.pdf)Open this link in a new window
   by www.bayerresources.com.au    
Levovist®(.pdf)Open this link in a new window
   by www.bayerresources.com.au    
  News & More:
Dynamic Sonography of Pancreatic Tumors: Comparison with Dynamic CT(.pdf)Open this link in a new window
Wednesday, 1 May 2002   by www.ajronline.org    
The role of ultrasound in molecular imaging(.pdf)Open this link in a new window
2003   by bjr.birjournals.org    
US Resources  
Societies - Modes - UltraSound Training Courses - Endoscopic - - Contrast Agents
 
Related Searches:
 • SONOLINE Omnia
 • A-Mode
 • Interventional Ultrasound
 • BG1135
 • Ultrasound Picture
SEARCH FOR   
 
  12345ABCDEFGHIJKLMNOPQRSTUVWZ
previous      21 - 25 (of 36)     next
Result Pages : [1 2]  [3 4 5 6 7 8]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

US-TIP    
Community   
User
Pass
Forgot your UserID/Password ?  


Look
      Ups



UltraSound - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • US-TIP • 
Copyright © 2006 - 2018 SoftWays. All rights reserved.
Terms of Use | Privacy Policy | Advertising