Philips Medical SystemsMRI Resource Directory:
 - Manufacturers -
 
www.medical.philips.com/main/products/mri/index.wpd Philips Medical System is the diagnostics business of Royal Philips Electronics of the Netherlands, one of the world's biggest electronics companies and Europe's largest. Philips is quoted on the NYSE (symbol: PHG), London, Frankfurt, Amsterdam and other stock exchanges. On October 19, 2001, Philips Medical Systems completed a 3-year acquisition strategy through its purchase of Marconi Medical Systems. Marconi Medical Systems offered leading multislice CT, MRI, and Nuclear Gamma Camera systems to medical institutions around the world. As well as new 3.0T developments, Philips is also in collaboration with researchers at the University of Nottingham, with the intention of developing an ultrahigh field strength clinical 7.0T whole body MR system.

MRI Scanners:

Contact Information
MAIL
Philips Medical Systems
3000 Minuteman Road
Andover, MA 01810-1099
USA
PHONE
+1-978-687-1501
E-MAIL ASIA PACIFIC
spacer
 
• Share the entry 'Philips Medical Systems':  Facebook  Twitter  LinkedIn  
 
• Related Searches:
    • MRI Scan
    • Shielding
    • Permanent Magnet
    • Hardware
    • MRI Procedure
 
Further Reading:
  News & More:
RSNA update on new MRI technology(.pdf)
February 2006   by www.magnet-mri.org    
MRI Resources 
Service and Support - Absorption and Emission - Raman Spectroscopy - - Diffusion Weighted Imaging - MRA
 
Marconi Medical SystemsMRI Resource Directory:
 - Manufacturers -
 
On October 19, 2001, Philips Medical Systems completed an acquisition strategy through its purchase of Marconi Medical Systems.

The History of Marconi Medical Systems
2001 Royal Philips Electronics and Marconi plc announced that Philips has agreed to acquire Marconi Medical Systems for $1.1 billion.
2000 Marconi introduces Infinite Detector Technology for Mx8000 multislice CT scanner, which acquires an unprecedented 16 simultaneous slices with sub-millimeter isotropic accuracy.
1999 At RSNA, Picker International unveils the new Marconi Medical Systems name and corporate vision.
1998 Picker International acquires the Computed Tomography Division of Elscint Ltd, immediately positioning Picker at the forefront of major global CT suppliers.
1986 Picker produces the industry's first 1.0T MR imager.
1981 Picker is sold to General Electric Co. Ltd. of England (GEC). Picker merged with Cambridge Instruments, GEC Medical, and American Optical to form Picker International.
1967 The name changed from Picker X-ray to Picker Corporation. Picker acquired Dunlee.
1946 The Dunlee Corporation started in Chicago by Dunmore Dunk and Zed. J. Atlee to meet demand for quality X-ray tubes and special purpose tubes.
1915 James Picker Company formed in New York City offering sales and service of X-ray equipment, film and accessories.

See also Philips Medical Systems and MRI History.
spacer

• View the DATABASE results for 'Marconi Medical Systems ' (3).Open this link in a new window

MRI Resources 
Spectroscopy - Lung Imaging - Safety pool - Safety Training - MRI Technician and Technologist Schools - Anatomy
 
EPIX Pharmaceuticals, Inc.MRI Resource Directory:
 - Developers -
 
www.epixmed.com [This entry is marked for removal.]

(July 20, 2009 - EPIX Pharmaceuticals, Inc. announced today that, in light of the company's lack of capital and inability to obtain additional financing or consummate a strategic transaction, it has entered into an Assignment for the Benefit of Creditors, effective immediately, in accordance with Massachusetts law).
EPIX has been a specialty pharmaceutical firm developing targeted contrast agents to improve the capability of MRI as a diagnostic tool for a variety of diseases. Gadofosveset trisodium (formerly MS-325, Vasovist™, now ABLAVARt™), is an injectable intravascular contrast agents designed for multiple vascular imaging applications, including peripheral vascular disease and coronary artery disease. EPIX conducted a pivotal Phase III trial for the detection of peripheral vascular disease, as well as a Phase II feasibility trial for coronary artery disease diagnosis.
To ensure rapid development and adoption of gadofosveset trisodium into clinical practice upon regulatory approval, EPIX pursued an aggressive product development plan and commercialization strategy. The Company established an exclusive, worldwide sales and marketing agreement with Bayer Schering Pharma AG. EPIX also established corporate collaborations with GE Healthcare, Philips Medical Systems and Siemens Medical Systems, the three leading MRI manufacturers, which together account for approximately 80 percent of the MRI machines installed worldwide.
EPIX had other MRI contrast agents under development, most significantly a novel prototype blood clot agent (EP-2104R). Potential clinical applications for this type of agent include detection of deep venous thrombosis, pulmonary embolism and blood clots in the coronary and carotid arteries. Currently, there is no high resolution imaging technique to directly visualize blood clots in patients with suspected cardiovascular disease.
spacer

• View the DATABASE results for 'EPIX Pharmaceuticals, Inc.' (7).Open this link in a new window


• View the NEWS results for 'EPIX Pharmaceuticals, Inc.' (69).Open this link in a new window.
 
Further Reading:
  Basics:
Epix Pharmaceuticals to shut down
Tuesday, 21 July 2009   by boston.bizjournals.com    
MRI Resources 
Spectroscopy - Safety pool - Colonography - Calculation - Open Directory Project - Mass Spectrometry
 
Infinion 1.5TPanorama 0.2InfoSheet: - Devices -
Intro, 
Types of Magnets, 
Overview, 
etc.MRI Resource Directory:
 - Devices -
 
From Philips Medical Systems; www.medical.philips.com/main/products/mri/products/infinion1.5t/features/ Philips Infinion 1.5 T is designed to maximize the efficiency and quality of patient care. Developed with the patient in mind, the Infinion is the shortest and most open 1.5T scanner available. The unique 'ultra short' 1.4 m magnet assures patient comfort and acceptance without compromising image quality and clinical performance.
Device Information and Specification
CLINICAL APPLICATION
Whole body
CONFIGURATION
Ultra short bore
Head, head / neck, integrated C-spine, L/T spine array, small large GP coils, body flex array, torso pelvis array, breast array, endocavitary, shoulder array, lower extremity, hand / wrist, cardiac, PV array
SYNCHRONIZATION
ECG/peripheral, respiratory gating
PULSE SEQUENCES
SE, TSE, SS TSE, EPI, IR, STIR, FLAIR, FFE, TFE, T1 TFE, T2 TFE, Presat, Fatsat, MTC, Diff-opt., Angiography: PCA, MCA, TOF
IMAGING MODES
Single slice, single volume, multi slice, multi volume
TR
3.1 msec minimum
TE
0.9 msec minimum
SINGLE/MULTI SLICE
80 images/sec std.; up to320 opt.@256
FOV
0.4 - 56 cm
2D: 0.3 mm; 3D: 0.2 mm
1024 x 1024
MEASURING MATRIX
8 x 8 to 1024 x 1024
PIXEL INTENSITY
256 gray scale
BORE DIAMETER
or W x H
60 cm diameter (patient)
MAGNET WEIGHT
4100 kg w/cryogen's
H*W*D
233 (lead fitted) x 198 x 140 cm
POWER REQUIREMENTS
400/480 V
COOLING SYSTEM TYPE
Closed loop, chilled water
CRYOGEN USE
0.06 L/hr helium
STRENGTH
30 mT/m
5-GAUSS FRINGE FIELD
3.0 m / 5.0 m
Passive/active
spacer

• View the DATABASE results for 'Infinion 1.5T™' (2).Open this link in a new window

MRI Resources 
Safety pool - Shielding - Knee MRI - Online Books - Mobile MRI Rental - Devices
 
Intera 0.5TPanorama 0.2InfoSheet: - Devices -
Intro, 
Types of Magnets, 
Overview, 
etc.MRI Resource Directory:
 - Devices -
 
www.medical.philips.com/de/products/mri/products/ From Philips Medical Systems;
this low field MRI system of the Intera-family is onto diagnostic safety and flexibility aligned - cost effective and with high patient acceptance.
Device Information and Specification
CLINICAL APPLICATION
Whole body
CONFIGURATION
Short bore compact
Standard: head, body, C1, C3; Optional: Small joint, flex-E, flex-R, endocavitary (L and S), dual TMJ, knee, neck, T/L spine, breast; Optional phased array: Spine, pediatric, 3rd party connector, Flex-S-M-L, flex body, flex cardiac, neuro-vascular, head
SYNCHRONIZATION
ECG/peripheral: Optional/yes, respiratory gating
PULSE SEQUENCES
SE, Modified-SE (TSE), DAVE, STIR, FLAIR, SPIR, MTC, Dynamic, Keyhole, CLEAR, Q Flow, Balanced FFE, Multi Chunk 3D, Multi Stack 3D, FFE-EPI, SE-EPI, IR-EPI, GRASE, Diffusion Imaging, Perfusion Imaging;; Angiography: Inflow MRA, TONE, PCA, CE MRA
IMAGING MODES
Single Slice 2D , Multi Single Slice 2D, Multi Slice 2D, 3D, Multi Chunk 3D, Multi Stack 3D
TR
Min. 2.9 (Omni) msec
TE
Min. 1.0 (Omni) msec
SINGLE/MULTI SLICE
RapidView Recon. greater than 500 @ 256 Matrix
FOV
Max. 53 cm
0.1 mm (Omni)
128 x 128, 256 x 256,512 x 512,1024 x 1024
MEASURING MATRIX
Variable in 1% increments
PIXEL INTENSITY
Lum.: 120 cd/m2; contrast: 150:1
Variable (op. param. depend.)
60 x 60 cm
MAGNET WEIGHT
2500 kg
H*W*D
240 x 188 x 157 cm
POWER REQUIREMENTS
380/400 V
CRYOGEN USE
0.03 L/hr helium
STRENGTH
23 mT/m (Omni)
5-GAUSS FRINGE FIELD
2.1 m / 2.8 m
Passive and dynamic
spacer

• View the DATABASE results for 'Intera 0.5T™' (2).Open this link in a new window

MRI Resources 
Implant and Prosthesis - MRI Physics - Journals - Coils - Chemistry - Hospitals
 
     1 - 5 (of 14)     next
Result Pages : [1]  [2 3]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



Personalized protocols (age, gender, body habitus, etc.) lead to :
more automated planning 
improved patient comfort 
better diagnostics 
optimized image quality 
nothing 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 29 March 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]