Magnetic Resonance - Technology Information Portal Welcome to MRI Technology
Info
  Sheets

Out-
      side
 



 
 'Ultrasmall Superparamagnetic Iron Oxide' 
SEARCH FOR    
 
  2 3 5 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Result : Searchterm 'Ultrasmall Superparamagnetic Iron Oxide' found in 1 term [] and 16 definitions []
previous     6 - 10 (of 17)     next
Result Pages : [1]  [2 3 4]
Searchterm 'Ultrasmall Superparamagnetic Iron Oxide' was also found in the following service: 
spacer
News  (1)  
 
Supravist™InfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
Short name: SHU 555 C, preliminary trade name: Supravist™
An ultrasmall superparamagnetic iron oxide under development as a positive enhancing blood pool agent (MRI contrast agent phase III, Bayer Schering Pharma AG). Supravist™ can be administered as an iv. bolus up to doses of 80 μmol/kg.

See also Ultrasmall Superparamagnetic Iron Oxide and Blood Pool Agents.
spacer
MRI Resources 
Image Quality - DICOM - Pathology - Patient Information - Knee MRI - Abdominal Imaging
 
Bolus Injection
 
A bolus is a rapid infusion of high dose contrast agent. Dynamic and accumulation phase imaging can be performed after bolus injection. Since the transit time of the bolus through the tissue is only a few seconds, high temporal resolution imaging can be required to obtain sequential images during the wash in and wash out of the contrast material and, therefore, resolve the first pass of the tracer.
For the same injected dose of contrast agent the injection rate (and, consequently, the total injected volume) modifies the bolus peak profile. Increasing the injection rate produces a sharpening of the peak (Cmax increase, Tmax decrease, peak length decrease). At a low injection rate, the first pass presents a plateau form. Substantial changes in the gadolinium concentrations during signal acquisition induce artifacts. Furthermore, the haemodynamic parameters (cardiac output, blood pressure) influence the bolus profile. The characteristics of gadolinium agents are favorable in the early bolus phase, whereas the advantages of large complexes (e.g. blood pool agents) and ultrasmall superparamagnetic iron oxide (USPIO) are most evident in the distribution phase.
 
Images, Movies, Sliders:
 Left Circumflex Ischemia First-pass Contrast Enhancement  Open this link in a new window
      

Courtesy of  Robert R. Edelman

 Normal Lung Gd Perfusion MRI  Open this link in a new window
 
spacer

• View the DATABASE results for 'Bolus Injection' (9).Open this link in a new window

 
Further Reading:
  News & More:
Contrast Bolus Timing and Scan Delay
2003   by www.med.nyu.edu    
MRI Resources 
Chemistry - Crystallography - DICOM - Implant and Prosthesis pool - Pregnancy - Equipment
 
Clariscan™InfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
An iron-based contrast agent with large molecular size, which prevents diffusion into body tissues and will be developed for MR imaging of the liver (taken up by macrophages), tumor microvasculature and microvessel permeability. The blood half live of the particles with 11-20 nm diameter is 3-4 hours.
At this time the development of Clariscan™ is discontinued.

See also NC100150 Injection and Ultrasmall Superparamagnetic Iron Oxide.
Drug Information and Specification
NAME OF COMPOUND
Feruglose, PEG-feron, USPIO, NC100150
DEVELOPER
CENTRAL MOIETY
Fe
CONTRAST EFFECT
T2, Predominantly negative enhancement
R1=20, R2=35, B0=0.5T
PHARMACOKINETIC
Intravascular
CONCENTRATION
29.8 mg Fe/mL
PREPARATION
Suspend in an isotonic glucose solution
INDICATION
Cardiovascular
DEVELOPMENT STAGE
?
DO NOT RELY ON THE INFORMATION PROVIDED HERE, THEY ARE
NOT A SUBSTITUTE FOR THE ACCOMPANYING PACKAGE INSERT!
spacer

• View the DATABASE results for 'Clariscan™' (6).Open this link in a new window

 
Further Reading:
  News & More:
GE Healthcare expands MRI contrast media product range in Europe with launch of macrocyclic agent ClariscanTM
Wednesday, 1 March 2017   by www.businesswire.com    
GE Healthcare announces FDA approval of macrocyclic MRI contrast agent Clariscan
Monday, 4 November 2019   by www.itnonline.com    
Searchterm 'Ultrasmall Superparamagnetic Iron Oxide' was also found in the following service: 
spacer
News  (1)  
 
Combidex®InfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
Combidex® is the brand name (same as Sinerem®) for an ultrasmall superparamagnetic iron oxide (USPIO) in the development pipeline to detect metastatic disease in lymph nodes. Metastatic lymph nodes show less uptake of this MRI contrast agent, which results in less signal decrease and allows the differentiation of normal lymph nodes from normal-sized, metastatic nodes. Combidex® has also potential to be used as a functional molecular imaging agent.
In March 2005, AMAG Pharmaceuticals Inc received an approvable letter from the U.S. Food and Drug Administration with respect to Combidex subject to certain conditions.
See also Ferumoxtran, Drug Development and Approval Process USA, Molecular Imaging and Classifications, Characteristics, etc.
Drug Information and Specification
NAME OF COMPOUND
Ferumoxtran, USPIO, AMI-227
CENTRAL MOIETY
Fe3+/Fe2+
CONTRAST EFFECT
T1, predominantly T2
r1=25, r2=160, B0=0.47T, r1=23.3, r2=48.9, B0=0.47T
PHARMACOKINETIC
Vascular, lymph v. hepatocyte (AG-USPIO)
DOSAGE
2.6 mg Fe/kg
PREPARATION
Suspend in an isotonic glucose solution
INDICATION
Lymph node, (MR angiography vascular, staging of RES-directed liver diseases)
DO NOT RELY ON THE INFORMATION PROVIDED HERE, THEY ARE
NOT A SUBSTITUTE FOR THE ACCOMPANYING PACKAGE INSERT!
spacer

• View the DATABASE results for 'Combidex®' (6).Open this link in a new window


• View the NEWS results for 'Combidex®' (1).Open this link in a new window.
 
Further Reading:
  Basics:
The demise of Combidex - Sinerem
Wednesday, 24 March 2010   by www.wellsphere.com    
  News & More:
Combidex, MRI, and identification of nodal metastases
Wednesday, 17 June 2009   by prostatecancerinfolink.net    
Superparamagnetic Iron Oxide–enhanced MR Imaging of Head and Neck Lymph Nodes1
MRI Resources 
Brain MRI - Supplies - Process Analysis - Raman Spectroscopy - NMR - Open Directory Project
 
Fe O-BPAInfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.
 
Short name: Fe O-BPA, central moiety: Fe3+/Fe2+
An ultrasmall superparamagnetic iron oxide under development (preclin.) as a vascular contrast agent for MR angiography.

See also USPIO.
spacer
MRI Resources 
Spectroscopy - Brain MRI - Diffusion Weighted Imaging - Health - Chemistry - Cardiovascular Imaging
 
previous      6 - 10 (of 17)     next
Result Pages : [1]  [2 3 4]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



New acceleration techniques will :
reduce scan times 
cause artifacts 
increase expenses 
be useful if you have a lot of experience 
doesn't do much 
never heard of 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 25 April 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]