Magnetic Resonance - Technology Information Portal Welcome to MRI Technology
Info
  Sheets

Out-
      side
 



 
 'Transverse Magnetization' 
SEARCH FOR    
 
  2 3 5 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Result : Searchterm 'Transverse Magnetization' found in 1 term [] and 42 definitions []
previous     26 - 30 (of 43)     next
Result Pages : [1]  [2 3 4 5 6 7 8 9]
MRI Resources 
Spectroscopy - Non-English - Used and Refurbished MRI Equipment - Brain MRI - MRI Technician and Technologist Schools - Colonography
 
Hahn Echo
 
Production of spin echo by repeated RF pulses. First observed using equal (90°) RF pulses, now commonly used to describe refocusing of transverse magnetization by a 180° RF pulse. By choosing long echo delay times, the spins in a Hahn echo first dephase for a long time, then rephase, which makes the Hahn pulse sequence more susceptible to diffusion effects.
spacer
 
Further Reading:
  Basics:
Magnetic resonance imaging
   by www.scholarpedia.org    
MRI Resources 
Movies - Jobs - Collections - Breast MRI - Software - MR Guided Interventions
 
Homospoil
 
Use of a magnetic field gradient to effectively eliminate residual transverse magnetization by producing a strong position dependence of phase within a resolution element. See Spoiler Gradient Pulse.
spacer

• View the DATABASE results for 'Homospoil' (2).Open this link in a new window

MRI Resources 
MRI Accidents - Implant and Prosthesis pool - Journals - Lung Imaging - Chemistry - Stimulator pool
 
Incoherent Gradient Echo (RF Spoiled)InfoSheet: - Sequences - 
Intro, 
Overview, 
Types of, 
etc.
 
A gradient echo is generated by using a pair of bipolar gradient pulses. The gradient field is negatively pulsed, causing the spins of the xy-magnetization to dephase. A second gradient pulse is applied with the opposite polarity. During the pulsing, the spins that dephased begin to rephase and generate a gradient echo.
Spoiling can be accomplished by RF or a gradient. The incoherent RF spoiled type of a gradient echo sequence use a continuous shifting of the RF pulse to spoil the residual transverse magnetization. The phase of the RF excitation and receiver channel are varied pseudo randomly with each excitation cycle to prevent the xy magnetization from achieving steady state. T2* does not dominate image contrast, so T1 and PD weighting is practical. This method is effective and can be used to achieve a shorter TR, due to a lack of additional gradients. Spoiling eliminates the effect of the remaining xy-magnetization and leads to steady state longitudinal magnetization. These sequences can be used for breath hold, dynamic imaging and in cine and volume acquisitions.
spacer
MRI Resources 
Stimulator pool - MRI Technician and Technologist Jobs - Contrast Enhanced MRI - Abdominal Imaging - Breast Implant - Shielding
 
Incoherent Spins
 
A state of a set of spins in which the ensemble of spins in a voxel are uniformly distributed with phases between 0 and 2p reducing the transverse magnetization in a voxel to essentially zero.
spacer
MRI Resources 
Contrast Agents - Safety Products - MRI Physics - Education pool - MRCP - Calculation
 
Proton Density Weighted Image
 
An image produced by controlling the selection of scan parameters to minimize the effects of T1 and T2, resulting in an image dependent primarily on the density of protons in the imaging volume. Proton density contrast is a quantitative summary of the number of protons per unit tissue. The higher the number of protons in a given unit of tissue, the greater the transverse component of magnetization, and the brighter the signal on the proton density contrast image. Conversely the lower the number of protons in a given unit of tissue, the less the transverse magnetization and the darker the signal on the proton density image. Also called (Rho) ρ-weighted.

See also Density Weighted Imaging and Image Contrast Characteristics.
 
Images, Movies, Sliders:
 Knee MRI Coronal Pd Spir 001  Open this link in a new window
    
 
spacer

• View the DATABASE results for 'Proton Density Weighted Image' (4).Open this link in a new window

 
Further Reading:
  Basics:
Musculoskeletal MRI at 3.0 T: Relaxation Times and Image Contrast
Sunday, 1 August 2004   by www.ajronline.org    
Dogs Are People, Too
Saturday, 5 October 2013   by www.nytimes.com    
MRI Resources 
MR Myelography - MR Guided Interventions - Diffusion Weighted Imaging - Shielding - Stent - Spectroscopy
 
previous      26 - 30 (of 43)     next
Result Pages : [1]  [2 3 4 5 6 7 8 9]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



MRI is trending to low field magnets :
reduced costs will lead to this change 
AI will close the gap to high field 
only in remote areas 
is only temporary 
never 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 20 April 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]